Nucor Fastener Division
6730 County Road 60, 46785, St. Joe, IN, United States
Visit website- Accredited standards
- 17
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 17 standard numbers and the 10 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM14
ASTM A194
ASTM A370Standard Test Methods and Definitions for Mechanical Testing of Steel Products
ASTM B487Standard Test Method for Measurement of Metal and Oxide Coating Thickness by Microscopical Examination of Cross Section
ASTM B499
ASTM E3Standard Guide for Preparation of Metallographic Specimens
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM E376Standard Practice for Measuring Coating Thickness by Magnetic-Field or Eddy Current (Electromagnetic) Testing Methods
ASTM E384Standard Test Method for Microindentation Hardness of Materials
ASTM E1444
ASTM F606Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets
ASTM F788
ASTM F812
ASTM F1470
ASTM F3125
ISO3
ISO 898-1Mechanical properties of fasteners made of carbon steel and alloy steel - Part 1: Bolts, screws and studs with specified property classes - Coarse thread and fine pitch thread
ISO 898-2Fasteners - Mechanical properties of fasteners made of carbon steel and alloy steel - Part 2: Nuts with specified property classes
ISO 6157-1Fasteners - Surface discontinuities - Part 1: Bolts, screws and studs for general requirements
ASME/ANSI B18.18.1M through B18.18.7M; ASTM F1470; ASTM E18; ASTM F606/F606M; SAE J417; SAE J429; SAE J995; SAE J1216; ASTM E384; ISO 898-1; ASTM A370; ISO 898-2; SAE J995; ASTM F3125; ASTM F788/F788M; ASTM F812/F812M; ISO 6157-1; SAE J122; SAE J123; SAE J1061; ASTM F3125/F3125M; FHWA Supplemental Contract Specification3; ASTM A194 Section 8.1.5; ASTM B487; ASTM B499; ASTM E376
ASTM E3; ASTM F3125/F3125M; F2328/F2328M; SAE, J419; ASTM E1444/E1444M; ASME B 1.1; B1.2; FED-STD-28/; ASME B18.2.1; B18.2.2; ASME B18.2.3.1M; B18.2.3.3M; ASME B18.2.3.5M; Digital calipers/ ASME B18.2.3.6M; B18.2.4.1M; Optical comparator / ASME B18.2.4.2; B18.2.4.2M digital indicator/ ASME B18.2.6; Contour tracer / ASME B18.2.4.2; B18.2.4M; B18.2.1; B18.2.6; Vision Lab/ ASME B18.2.1; B18.2.2: ASME B18.2.3.1M; B18.2.3.3M: ASME B18.2.3.5M: ASME B18.2.3.6M, B18.2.4.1M
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active139.01
The scope document we hold says it is valid until 2027-12-31.
Accredited scope, certificate 139.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASME/ANSI B18.18.1M through B18.18.7M; ASTM F1470; ASTM E18; ASTM F606/F606M; SAE J417; SAE J429; SAE J995; SAE J1216; ASTM E384; ISO 898-1; ASTM A370; ISO 898-2; SAE J995; ASTM F3125; ASTM F788/F788M; ASTM F812/F812M; ISO 6157-1; SAE J122; SAE J123; SAE J1061; ASTM F3125/F3125M; FHWA Supplemental Contract Specification3; ASTM A194 Section 8.1.5; ASTM B487; ASTM B499; ASTM E376 | Steel | - |
| 2 | ASTM E3; ASTM F3125/F3125M; F2328/F2328M; SAE, J419; ASTM E1444/E1444M; ASME B 1.1; B1.2; FED-STD-28/; ASME B18.2.1; B18.2.2; ASME B18.2.3.1M; B18.2.3.3M; ASME B18.2.3.5M; Digital calipers/ ASME B18.2.3.6M; B18.2.4.1M; Optical comparator / ASME B18.2.4.2; B18.2.4.2M digital indicator/ ASME B18.2.6; Contour tracer / ASME B18.2.4.2; B18.2.4M; B18.2.1; B18.2.6; Vision Lab/ ASME B18.2.1; B18.2.2: ASME B18.2.3.1M; B18.2.3.3M: ASME B18.2.3.5M: ASME B18.2.3.6M, B18.2.4.1M | - | 0.25 to 1.5 in |
| 3 | MIL-STD-120; ASME B18.2.1; B18.2.6 | - | See scope document |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
NUCOR FASTENER DIVISION
St. Joe, IN
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 9th day of January 2026.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 0139.01
Valid to December 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- AFI IndustriesCarol Stream, IL · ~206 kmA2LAShares 2 accredited test methodsASTM E18ASTM E3
- Trescal, Inc - Milwaukee, WIMilwaukee, WI · ~224 kmA2LAShares 2 accredited methods and materialsASTM E18Steel
- Metallurgical SolutionsDayton, OH · ~269 kmA2LAShares 2 accredited test methodsASTM E18ASTM E3
- American Testing Services,Miamisburg, OH · ~283 kmA2LAShares 2 accredited test methodsASTM E18ASTM E3
- All American Scales & CalibrationParis, OH · ~394 kmA2LAShares 2 accredited methods and materialsASTM E18Steel
Accreditation data refreshed from the A2LA register on .