Constellation Powerlabs - New England Division
8 Colorado Street, 12903, Plattsburgh, NY, United States
Visit website- Scope lines
- 14
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 14 scope lines.
A2LA certificate 2044.02 · 14 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006 | - | to 1 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.02) 09/05/2025 Page 2 of 13
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
DC Voltage – Generate
(0 to 220) mV
220 mV to 2.2 V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
9 µV/V + 0.8 µV
8 µV/V + 1.2 µV
8 µV/V + 4 µV
8 µV/V + 8.6 µV
9 µV/V + 100 µV
11 µV/V + 600 µV
Primary multi-function
calibrator
DC Current – Measure
(10 to 120) µA
100 µA to 1.2 mA
(1 to 12) mA
(10 to 120) mA
100 mA to 1.05 A
25 µA/A + 0.8 nA
25 µA/A + 5 nA
25 µA/A + 50 nA
40 µA/A + 500 nA
0.012 % + 10 µA
Long scale multimeter
DC Current – Generate
(0 to 220) µA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
60 µA/A + 10 nA
60 µA/A + 10 nA
60 µA/A + 100 nA
70 µA/A + 1 µA
95 µA/A + 30 µA
0.036 % + 480 µA
Primary multi-function
calibrator with precision
amplifier
See footnote 4
See footnote 5
Resistance – Measure
(0 to 12) Ω
(10 to 120) Ω
(100 to 1200) Ω
(1 to 12) kΩ
(10 to 120) kΩ
100 kΩ to 1.2 MΩ
(1 to 12) MΩ
(10 to 120) MΩ
(9 to 90) MΩ
(90 to 900) MΩ
900 MΩ to 1 GΩ
(9 to 90) GΩ
(90 to 900) GΩ
900 GΩ to 1 TΩ
18 µΩ/Ω + 51 µΩ
15 µΩ/Ω + 500 µΩ
13 µΩ/Ω + 500 µΩ
13 µΩ/Ω + 5 mΩ
13 µΩ/Ω + 50 mΩ
18 µΩ/Ω + 2 Ω
53 µΩ/Ω + 100 Ω
0.05 % + 1 kΩ
0.029 % + 500 Ω
0.041 % + 5 kΩ
0.058 % + 100 kΩ
0.081 % + 1 MΩ
0.12 % + 5 MΩ
0.23 % + 400 MΩ
Long scale multimeter
Precision high resistance
meter | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.02) 09/05/2025 Page 3 of 13
Parameter/Equipment
Range
CMC2, 6, 7 (±)
Comments
Resistance – Generate,
Fixed Points
DC Resistance
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
1 mΩ
10 mΩ
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
60 µΩ
0.012 %
0.012 %
33 µΩ/Ω
32 µΩ/Ω
20 µΩ/Ω
20 µΩ/Ω
15 µΩ/Ω
15 µΩ/Ω
14 µΩ/Ω
14 µΩ/Ω
16 µΩ/Ω
16 µΩ/Ω
23 µΩ/Ω
24 µΩ/Ω
46 µΩ/Ω
55 µΩ/Ω
0.013 %
0.10 %
0.10 %
0.10 %
0.10 %
0.03 %
0.02 %
0.02 %
0.02 %
0.02 %
Precision multi-function
calibrator
Precision 4-terminal
resistance set
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
AC Resistance –
Measure
(10 to 100) mΩ
100 mΩ to 25 kΩ
26 kΩ to 20 MΩ
(2 to 20) MΩ
30 Hz to 10 kHz
12 Hz to 100 kHz
12 Hz to 20 kHz
12 Hz to 1 kHz
0.66 %
0.03 %
0.03 %
0.08 %
Precision impedance
meter | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.02) 09/05/2025 Page 4 of 13
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
AC Resistance –
Generate, Fixed Points
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
DC to 1 MHz
DC to 1 MHz
DC to 100 kHz
100 kHz to 1 MHz
DC to 100 kHz
100 kHz to 1 MHz
DC to 100 kHz
100 kHz to 1 MHz
0.12 %
0.12 %
0.12 %
0.08 %
0.08 %
0.08 %
0.08 %
0.12 %
Precision 4-terminal
resistance set
AC Voltage – Measure
(1 to 12) mV
(12 to 120) mV
120 mV to 1.2 V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
0.03 % + 3 µV
0.02 % + 1.1 µV
0.03 % + 1.1 µV
0.1 % + 1.1 µV
0.5 % + 1.1 µV
4 % + 2 µV
72 µV/V + 4 µV
72 µV/V + 2 µV
0.014 % + 2 µV
0.03 % + 2 µV
0.08 % + 2 µV
0.3 % + 10 µV
1 % + 10 µV
1.5 % + 10 µV
72 µV/V + 40 µV
72 µV/V + 20 µV
0.014 % + 20 µV
0.03 % + 20 µV
0.08 % + 20 µV
0.3 % + 100 µV
1 % + 100 µV
1.5 % + 100 µV
Long scale multimeter | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.02) 09/05/2025 Page 5 of 13
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage – Measure
(cont)
(1.2 to 12) V
(12 to 120) V
(120 to 700) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
72 µV/V + 0.4 mV
72 µV/V + 0.2 mV
0.014 % + 0.2 mV
0.03 % + 0.2 mV
0.08 % + 0.2 mV
0.3 % + 1 mV
1 % + 1 mV
1.5 % + 1 mV
0.02 % + 4 mV
0.02 % + 2 mV
0.02 % + 2 mV
0.035 % + 2 mV
0.12 % + 2 mV
0.4 % + 10 mV
1.5 % + 10 mV
0.04 % + 40 mV
0.04 % + 20 mV
0.06 % + 20 mV
0.12 % + 20 mV
0.3 % + 20 mV
Long scale multimeter
AC Voltage –
Generate
(0.22 to 2.2) mV
(2.2 to 22) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
0.06 % + 5 µV
0.024 % + 5 µV
0.012 % + 5 µV
0.041 % + 5 µV
0.095 % + 8 µV
0.13 % + 15 µV
0.18 % + 30 µV
0.36 % + 30 µV
0.06 % + 6 µV
0.024 % + 6 µV
0.012 % + 6 µV
0.041 % + 6 µV
0.095 % + 8 µV
0.13 % + 15 µV
0.18 % + 30 µV
0.36 % + 30 µV
Precision multi-
function calibrator | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.02) 09/05/2025 Page 6 of 13
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage – Generate
(cont)
(22 to 220) mV
220 mV to 2.2 V
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(220 to 750) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
0.06 % + 16 µV
0.024 % + 11 µV
0.011 % + 10 µV
0.036 % + 11 µV
0.09 % + 30 µV
0.11 % + 30 µV
0.18 % + 40 µV
0.36 % + 100 µV
0.06 % + 100 µV
0.018 % + 34 µV
85 µV/V + 8.8 µV
0.014 % + 25 µV
0.028 % + 80 µV
0.048 % + 150 µV
0.12 % + 400 µV
0.24 % + 1 mV
0.06 % + 1 mV
0.018 % + 340 µV
86 µV/V + 70 µV
0.014 % + 300 µV
0.028 % + 430 µV
0.06 % + 1.7 mV
0.14 % + 5 mV
0.30 % + 9 mV
0.06 % + 10 mV
0.018 % + 3.3 mV
91 µV/V + 1.1 mV
0.025 % + 4.2 mV
0.06 % + 10 mV
0.16 % + 110 mV
0.54 % + 110 mV
1.3 % + 220 mV
90 µV/V + 4 mV
0.017 % + 6 mV
0.06 % + 11 mV
0.06 % + 11 mV
0.23 % + 45 mV
Precision multi-
function calibrator
Precision multi-
function calibrator
with precision
amplifier | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.02) 09/05/2025 Page 7 of 13
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current – Measure
(12 to 120) µA
120 µA to 1.2 mA
(1.2 to 12) mA
(12 to 120) mA
(0.12 to 1) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
0.4 % + 30 nA
0.15 % + 30 nA
0.06 % + 30 nA
0.06 % + 30 nA
0.4 % + 200 nA
0.15 % + 200 nA
0.06 % + 200 nA
0.03 % + 200 nA
0.4 % + 2 µA
0.15 % + 2 µA
0.06 % + 2 µA
0.03 % + 2 µA
0.4 % + 20 µA
0.15 % + 20 µA
0.06 % + 20 µA
0.03 % + 20 µA
0.4 % + 200 µA
0.16 % + 200 µA
0.08 % + 200 µA
0.1 % + 200 µA
Long scale multimeter
AC Current – Generate
(10 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.08 % + 30 nA
0.042 % + 25 nA
0.016 % + 20 nA
0.07 % + 50 nA
0.18 % + 100 nA
0.08 % + 50 nA
0.042 % + 40 nA
0.016 % + 40 nA
0.07 % + 500 nA
0.18 % + 1 µA
0.08 % + 500 nA
0.042 % + 400 nA
0.016 % + 400 nA
0.07 % + 5 µA
0.18 % + 10 µA
0.08 % + 5 µA
0.042 % + 4 µA
0.018 % + 4.1 µA
0.07 % + 50 µA
0.18 % + 100 µA
Precision multi-
function calibrator | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.02) 09/05/2025 Page 8 of 13
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
AC Current – Generate
(cont)
(0.22 to 2.2) A
(2.2 to 11) A
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.075 % + 40 µA
0.085 % + 100 µA
1.0 % + 200 µA
0.046 % + 170 µA
0.095 % + 380 µA
0.36 % + 750 µA
Precision multi-function
calibrator
Precision multi-function
calibrator with precision
amplifier
Inductance – Measure
(10 to 100) µH
100 µH to 1 mH
(1 to 16) mH
(16 to 40) mH
(40 to 100) mH
100 mH to 20 H
300 Hz to 100 kHz
30 Hz to 100 kHz
12 Hz to 100 kHz
12 Hz to 30 kHz
12 Hz to 10 kHz
12 Hz to 5 kHz
0.08 %
0.05 %
0.05 %
0.05 %
0.05 %
0.03 %
Precision impedance
meter
Capacitance – Measure
(10 to 100) pF
100 pF to 1 nF
1 nF to 1.6 µF
100 Hz to 20 kHz
100 Hz to 100 kHz
12 Hz to 100 kHz
0.15 %
0.03 %
0.03 %
Precision impedance
meter
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Capacitance – Generate
(0.19 to 0.4) nF
(0.4 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
(0.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
0.5 % + 0.01 nF
0.5 % + 0.01 nF
0.5 % + 0.01 nF
0.25 % + 0.01 nF
0.25 % + 0.1 nF
0.25 % + 0.1 nF
0.25 % + 0.3 nF
0.25 % + 1 nF
0.25 % + 3 nF
0.25 % + 10 nF
0.4 % + 30 nF
0.45 % + 100 nF
0.45 % + 300 nF
0.45 % + 1 μF
0.45 % + 3 μF
0.45 % + 10 μF
0.75 % + 30 μF
1.1 % + 100 μF
Precision multi-function
calibrator with
capacitance generation | ||
| 9 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.02) 09/05/2025 Page 9 of 13
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
Capacitance – Generate,
Fixed Points
1 pF
10 pF
100 pF
1000 pF
0.01 μF
0.1 μF
1 μF
1 kHz
1 MHz
1 kHz
1 MHz
1 kHz
1 MHz
1 kHz
1 MHz
120 Hz
1 kHz
10 kHz
100 kHz
120 Hz
1 kHz
10 kHz
100 kHz
120 Hz
1 kHz
10 kHz
100 kHz
0.036 %
0.05 %
0.01 %
0.025 %
0.01 %
0.025 %
0.01 %
0.05 %
0.025 %
0.01 %
0.025 %
0.05 %
0.025 %
0.01 %
0.025 %
0.05 %
0.04 %
0.01 %
0.04 %
0.1 %
Precision standard air
capacitor set
Phase – Generate
(0 to 90)°
(10 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.1°
0.25°
0.5°
2.5°
5°
10°
Precision multi-
function calibrator with
phase generation | 0 to 90 ° |
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.02) 09/05/2025 Page 10 of 13
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Electrical Calibration
of Thermocouple
Devices –
Type E
Type J
Type K
Type R
Type S
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -30) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.5 °C
0.16 °C
0.14 °C
0.16 °C
0.21 °C
0.27 °C
0.16 °C
0.14 °C
0.17 °C
0.23 °C
0.33 °C
0.18 °C
0.16 °C
0.26 °C
0.4 °C
0.57 °C
0.35 °C
0.33 °C
0.4 °C
0.47 °C
0.36 °C
0.37 °C
0.46 °C
0.63 °C
0.24 °C
0.16 °C
0.14 °C
Precision multi-
function calibrator
with temperature
generation
Oscilloscope –
50 Ω Load
1 MΩ Load
Squarewave Signal:
50 Ω at 1 kHz
1 MΩ:
10 Hz to 1 kHz
(1 to 10) kHz
(0 to 6.6) V
(0 to 130) V
1.0 mV to 6.6 V
pk – pk
1.0 mV to 130 V
pk – pk
1.0 mV to 130 Vpk – pk
0.25 % of output + 40 μV
0.05 % of output + 40 μV
0.25 % of output + 40 μV
0.1 % of output + 40 μV
0.25 % of output + 40 μV
Precision multi-
function calibrator
with waveform
generation | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.02) 09/05/2025 Page 11 of 13
Parameter/Equipment
Range
CMC2, 6, 7 (±)
Comments
Oscilloscope – (cont)
Level Sine Wave:
Amplitude
(50 kHz
Reference)
Flatness
(50 kHz
Reference)
Time Markers –
Source & Period
Into a 50 Ω Load
Rise Time:
≤ 2 MHz
> 2 MHz
Wave Generator
Amplitude
1 MΩ
50 Ω
Frequency
50 kHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
5 s to 50 ms
20 ms to 2 ns
(24 to 300) ps
(24 to 350) ps
1.8 mV to 55 V
pk – pk
1.8 mV to 2.5 Vpk – pk
10 Hz to 100 kHz
2 % + 300 µV
3.5 % + 300 µV
4 % + 300 µV
6 % + 300 µV
7 % + 300 µV
1.5 % + 100 µV
2 % + 100 µV
4 % + 100 µV
5 % + 100 μV
(25 + 1000t) parts in 10
6
2.5 parts in 106
+ 0 ps / -100 ps
+ 0 ps / -100 ps
3 % of output + 100 μV
3 % of output + 100 μV
25 parts in 10
6 + 15 mHz
Precision multi-
function calibrator with
waveform generation
t = time in seconds
III. Electrical – RF/ Microwave
Parameter/Range
Frequency
CMC2, 6, 7, 8 (±)
Comments
Power – Measure
1 mW, 50Ω
(10 to 30) MHz
0.41 %
Precision power meter
with reference mount &
long scale multimeter | to 1100 MHz |
| 12 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.02) 09/05/2025 Page 12 of 13
Parameter/Range
Frequency
CMC2, 6, 7, 8 (±)
Comments
Power – Measure (cont)
(-30 to +20) dBm, 50 Ω
(100 to 300) kHz
SWR ≤ 1.6:1
300 kHz to 1 MHz
SWR ≤ 1.2:1
1 MHz to 2 GHz
SWR ≤ 1.1:1
(2 to 4.2) GHz
SWR ≤ 1.3:1
(10 to 30) MHz
SWR ≤ 1.4:1
(30 to 50) MHz
SWR ≤ 1.18:1
50 MHz to 2 GHz
SWR ≤ 1.1:1
(2 to 12.4) GHz
SWR ≤ 1.18:1
(12.4 to 18) GHz
SWR ≤ 1.28:1
(50 to 100) MHz
SWR ≤ 1.15:1
100 MHz to 2 GHz
SWR ≤ 1.1:1
(2 to 12.4) GHz
SWR ≤ 1.15:1
(12.4 to 18) GHz
SWR ≤ 1.2:1
(18 to 26.5) GHz
SWR ≤ 1.25:1
0.13 dB
0.081 dB
0.078 dB
0.10 dB
0.069 dB
0.069 dB
0.071 dB
0.078 dB
0.097 dB
0.084 dB
0.087 dB
0.093 dB
0.1 dB
0.12 dB
Precision power meter
with precision power
sensor
IV. Mechanical
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Torque Wrenches
(5 to 6500) lbf·ft
0.65 %
Precision torque
transducer system | 5 to 6500 lbf·ft |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.02) 09/05/2025 Page 13 of 13
V. Time & Frequency
Parameter/Equipment
Range
CMC 2, 10 (±)
Comments
Frequency –
Measuring Equipment
0.01 Hz to 2 MHz
2.5 parts in 106 + 5 μHz
Precision multi-
function calibrator
Frequency – Measure
(1 to 100) Hz
100 Hz to 1 kHz
(1 to 10) kHz
(10 to 100) kHz
100 kHz to 1 MHz
(1 to 10) MHz
(10 to 100) MHz
(100 to 225) MHz
100 MHz to 1 GHz
(3 to 5) GHz
(5 to 12.4) GHz
1.8 μHz
1 μHz
10 μHz
100 μHz
1 mHz
10 mHz
100 mHz
230 mHz
1 Hz
5 Hz
12 Hz
Precision frequency
counter referenced to
the GPS __________________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Add to uncertainty specification: ±12 part in 106 x (Vin / 1000)2 for > 100 V.
4 Add to uncertainty specification: ±200 x I2 part in 106 for > 100 mA.
5 Add to uncertainty specification: ±10 x I2 for > 1 A.
6 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches;
R is the numerical value of the resolution of the device in microinches. % is defined as percentage of the
reading.
7 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
8 The CMC associated with RF Power measurement does not include mismatch.
9 This scope meets A2LA’s P112 Flexible Scope Policy.
10 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 14 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- HJM PrecisionTroy, NY · ~220 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- LAW CalibrationSaco, ME · ~275 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- M Precision Laboratories,Shirley, MA · ~280 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Associated Environmental SystemsNorth Chelmsford, MA · ~283 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hitachi High-Tech AmericaWestford, MA · ~286 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.