Crystal Engineering Corporation, an Ametek Inc. Company

708 Fiero Lane Suite 9, 93401, San Luis Obispo, CA, United States

Visit website
A2LA 2601.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 2601.01 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2601.01) 09/04/2025 Page 2 of 4 Parameter/Equipment Range CMC2, 3, 6 (±) Comments Resistance – Generate (0 to 100) Ω (100 to 400) Ω (400 to 2000) Ω (2 to 20) kΩ (20 to 200) kΩ (200 to 2000) kΩ 0.000 72 % + 10 µΩ 0.000 71 % 0.000 64 % + 2.5 mΩ 0.000 73 % + 8 mΩ 0.000 78 % + 60 mΩ 0.001 % + 1 Ω Fluke 1595A Fluke 8508A Fluke 5522A Resistance – Measure (0 to 100) Ω (100 to 400) Ω (400 to 2000) Ω (2 to 20) kΩ (20 to 200) kΩ (200 to 2000) kΩ 0.000 72 % + 10 µΩ 0.0007 % 0.000 66 % + 2 mΩ 0.000 75 % + 6 mΩ 0.000 78 % + 50 mΩ 0.000 95 % + 1 Ω Fluke 1595A II. Mechanical Parameter/Equipment Range CMC2, 3, 5 (±) Comments Pressure – Measuring Equipment (-13.5 to 0.2) psi Gauge (0.2 to 1.44) psi Gauge (1.45 to 55) psi Gauge (55 to 555) psi Gauge (555 to 3044) psi Gauge (3044 to 15 222) psi Gauge (0.8 to 1.44) psia Absolute (1.45 to 55) psia Absolute (55 to 555) psia Absolute 0.0018 % + 0.000 074 psi 0.0015 % + 0.000 067 psi 0.0012 % + 0.000 014 psi 0.0018 % + 0.000 11 psi 0.0019 % + 0.000 68 psi 0.0035 % + 0.006 psi 0.0072 % + 0.000 086 psia 0.0012 % + 0.000 012 psia 0.0018 % + 0.000 11 psia PG7601-10kPa/kg piston in differential mode PG7601-10kPa/kg piston in differential mode PG7601-10kPa/kg piston in gauge mode PG7601-100kPa/kg piston in gauge mode PG7202-200kPa/kg piston in gauge mode PG7202-1MPa/kg piston in gauge mode PPC4 100kPa in absolute mode PG7601-10kPa/kg piston in absolute mode PG7601-100kPa/kg piston in absolute mode
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2601.01) 09/04/2025 Page 3 of 4 Parameter/Equipment Range CMC2, 3, 5 (±) Comments Pressure – Measuring Equipment (cont) (555 to 3060) psia Absolute (3060 to 15 236) psia Absolute 0.0019 % + 0.0019 psia 0.0035 % + 0.007 psia PG7202-200kPa/kg piston in absolute mode PG7202-1MPa/kg piston in absolute mode III. Thermodynamics Parameter/Equipment Range CMC2, 3, 5 (±) Comments Temperature – Measure (-100 to 0) °C (0 to 155) °C (155 to 400) °C (400 to 660) °C (660 to 700) °C (700 to 1000) °C (1000 to 1205) °C 0.017 °C 0.018 °C 0.002 % + 0.015 °C 0.028 °C 0.55 °C 0.57 °C 0.75 °C Rosemount CE162, Fluke 1595A, Wika CER6000 Rosemount CE162, Fluke 1595A, Wika CER6000 Ametek TC-R, Fluke 8508 Temperature – Measuring Equipment (-100 to 155) °C (155 to 425) °C (425 to 660) °C (660 to 700) °C 0.018 °C 0.0015 % + 0.022 °C 0.0072 % 0.57 °C Rosemount CE162, Fluke 1595A, Wika CER6000, RTC-159, DLC-159 Rosemount CE162, Fluke 1595A, Wika CER6000, Ametek RTC-700, Ametek DLC-700 Ametek TC-R, Fluke 8508, Ametek RTC-700, Ametek DLC-700 ____________________________________________ 1 This laboratory offers limited commercial calibration services.
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2601.01) 09/04/2025 Page 4 of 4 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavi or of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
5ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

708 Fiero Lane Suite 9, San Luis Obispo, CA, 93401, US

35.35402, -120.37572

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.