Registers refreshed 2026-11-20.See refresh dates
United States

Gentex Corporation

600 North Centennial St., 49464, Zeeland, MI, United States

Visit website
A2LA 2529.01A2LA 2529.02ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
27
A2LA certificates
2
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 27 standard numbers and the 24 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60068 series9
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)

Certificate says EN 60068-2-6. Probably the same standard; not checked against the EN document.

IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock

Certificate says EN 60068-2-27. Probably the same standard; not checked against the EN document.

IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state

Certificate says EN 60068-2-78. Probably the same standard; not checked against the EN document.

ISO8
ISO 6270-2Paints and varnishes - Determination of resistance to humidity - Part 2: Condensation (in-cabinet exposure with heated water reservoir)
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic dischargeExclusion

Limits written next to it

ISO 10605 (2001, 2008, 2023) (excluding clause

Exclusion. Written next to it on line 2 of A2LA certificate 2529.01.

ISO 16505Road vehicles - Ergonomic and performance aspects of Camera Monitor Systems - Requirements and test procedures
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 20653Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access
ISO 11452 series4
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fieldsExclusion

Limits written next to it

ISO 11452-8 (2007, 2015) (excluding Helmholtz

Exclusion. Written next to it on line 2 of A2LA certificate 2529.01.

ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
Other standards6
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ETSI EN 300 220-2
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
IEC 16750-2
VW 80000

Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-20.

Scope as published by A2LA

10 lines
A2LA

ISO/IEC 17025

Active

2529.01

The scope document we hold says it is valid until 2027-03-31.

View scope
A2LA

ISO/IEC 17025

Active

2529.02

The scope document we hold says it is valid until 2027-03-31.

View scope

Location

600 North Centennial St., Zeeland, MI, 49464, US

42.81234, -86.01653

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.