Registers refreshed 2026-11-20.See refresh dates
Accredited lab directory · Part of the EN 1363 series

EN 1363-2 Accredited Testing Labs in United Kingdom

8 laboratories in United Kingdom are accredited by UKAS to perform EN 1363-2 testing. We don't know yet whether 2 of them take outside work. From the accredited scope text: “EN 1363-2:1999 A WALLS and PARTITIONS Fire Resistance BS 476:Part 8:1972:Section 2 BS 476:Part 21:1987:Section 8 FTSG Resolutions 47, 88 and 70 BS 476:Part 22:1987:Section 5 ISO 834:1975:Sections 5, 6” “EN 1363-2:1999 EN 1363-2:1999 Jordanstown Cardiff STRUCTURAL MEMBERS Resistance to fire tests Horizontal protective membranes. BS EN 13381-1:2020 EN 13381-1:2020 Jordanstown Vertical protective membra” “EN 1363-2:1999 BS 476 :Part 20 :1987 WALLS and PARTITIONS Fire Resistance BS 476:Part 22:1987 Clause 5 BS EN 1364-1:2015 DOORS & SHUTTER ASSEMBLIES Fire Resistance BS 476:Part 22:1987 Clause 6,7 & 8.” “EN 1363-2:1999 – Section 8 CAVITY BARRIERS Fire Resistance - vertical specimens EOTA Technical Report 31:2008 DOOR and SHUTTER ASSEMBLIES and ARCHITECTURAL HARDWARE Fire resistance BS 476-22:1987 – Se”

Labs
8
Primary AB
UKAS8 labs

Accredited Labs

Cambridge Fire Research

Cambridge, GB

Scope

EN 1363-2:1999, Section 8 Walls and partitions Fire resistance BS 476 Part 22:1987, Section 5 BS EN 1364-1:2015 Door and shutter assemblies Fire resistance BS 476 Part 22:1987, Sections 6, 7 and 8 BS EN 1634-1:2014+A1:2018

View lab

Efectis UK/Ireland

Jordanstown, GB

Scope

EN 1363-2:1999 EN 1363-2:1999 Jordanstown Cardiff STRUCTURAL MEMBERS Resistance to fire tests Horizontal protective membranes. BS EN 13381-1:2020 EN 13381-1:2020 Jordanstown Vertical protective membranes. B

View lab

Saint-Gobain Construction Products UK LTD t/a The Building Test Centre

Leicestershire, GB

Scope

EN 1363-2: 1999 BS EN 13381-2:2014 ASTM E119 (excluding hose stream test) A LIGHTWEIGHT PARTITIONS – NON- LOADBEARING Extended application of results from fire resistance tests BS EN 15254-3:2019 A FLOORS and FLAT ROOFS

View lab

Attain RTC

North Yorkshire, GB

Scope

EN 1363-2:1999 BS 476 :Part 20 :1987 WALLS and PARTITIONS Fire Resistance BS 476:Part 22:1987 Clause 5 BS EN 1364-1:2015 DOORS & SHUTTER ASSEMBLIES Fire Resistance BS 476:Part 22:1987 Clause 6,7 & 8. BS EN 1634-1:2014

View lab

United Kingdom Testing & Certification

Glasgow, GB

Scope

EN 1363-2:1999 – Section 8 CAVITY BARRIERS Fire Resistance - vertical specimens EOTA Technical Report 31:2008 DOOR and SHUTTER ASSEMBLIES and ARCHITECTURAL HARDWARE Fire resistance BS 476-22:1987 – Sections 6, 7 & 8 BS EN

View lab

Warringtonfire Testing and Certification Limited, trading as Warringtonfire

Buckinghamshire, GB

Scope

EN 1363-2:1999 A WALLS and PARTITIONS Fire Resistance BS 476:Part 8:1972:Section 2 BS 476:Part 21:1987:Section 8 FTSG Resolutions 47, 88 and 70 BS 476:Part 22:1987:Section 5 ISO 834:1975:Sections 5, 6, 7 and 8 BS EN 1364-1:201

View lab

Sherwin-Williams UK

Bolton, GB

We don't know yet whether this lab takes outside work.
Scope

EN 1363-2:1999 BS EN 13381-8:2013 BS EN 13381-10: 2020 FIRE PROTECTED STEEL Fire resistance testing BS EN 16623:2015 Annex C EAD 350402-00-1106 September 2017 Annex A END

View lab

International Paint

Tyne and Wear, GB

We don't know yet whether this lab takes outside work.
Scope

EN 1363-2:1999 BS EN 13381-6:2012 BS EN 13381-8:2013 ISO 834-1:1999/Amd 1:2012 ISO 834-5:2000 ISO 834-6:2000 ISO 834-7:2000 ISO 834-8:2002+corr. 2009 ISO/DIS 834-10:2014 ISO 834-12:2012 END

View lab

About ISO/IEC 17025 in United Kingdom

United Kingdom Accreditation Service (UKAS) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United Kingdom.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.