Registers refreshed 2026-11-20.See refresh dates
Accredited lab directory · Standard series

EN 2002 Accredited Testing Labs in United Kingdom

EN 2002, all parts14 laboratories in United Kingdom are accredited for at least one part of EN 2002, 13 of them by UKAS. We don't know yet whether 7 of them take outside work. Each lab card shows which parts it holds. From the accredited scope text: “EN 2002-2 LAN Forces 0.2 kN up to 400 kN Sub-Zero Temperature -1960C and -1000C to ambient BS EN ISO 6892-3 LAN Through thickness tensile BS EN 10164 ASTM A770/A770M MID Pipe and Pipeline Components R” “EN 2002-1 ASTM A370 ASTM E8/E8M Tensile (temperatures up to 900°C) (forces from 1.25kN to 250kN) BS EN ISO 6892-2 BS EN 2002-2 ASTM E21 Stress Rupture (temperature up to 900°C) Creep (temperature 300°” “EN 2002-1:2005 LT.01.02.12 Phenolic Mouldings, Reinforced Laminates, Phenolic Epoxy and Polyester, and Rubbers Tension (Up to 2500kN) AITM 1-0007 Issue 5 LT.01.02.12 Bearing Stress / Strength (Up to 2” “EN 2002-1 ASTM E8/E8M ASTM B557 ASTM A370 Izod Impact testing BS 131 Part 1 Charpy Impact (ambient Temperature) V-notch and U-Notch BS EN ISO 148-1 Fracture toughness (K1C & JC) ASTM E399 ASTM B645 AS”

Labs
14
Primary AB
UKAS13 labs
Parts of this series

Accredited Labs

Special Metals Wiggin Ltd trading as IncoTest

Hereford, GB

HoldsPart 1Part 2
Scope

EN 2002-1:2005 ASTM E8/E8M-24 ASTM A370-24a Tensile (temperature range ambient to 1000ºC) (Forces up to 600 kN) BS EN ISO 6892-2:2018 BS EN 2002-2:2005 ASTM E21-20 Tensile (temperature range -80ºC to ambient and -196 º

View lab

SGS United Kingdom

County Durham, GB

HoldsPart 1Part 2
Scope

EN 2002-1 ASTM A370 ASTM E8/E8M API Spec 5L ASTM B557M-15 CON (Forces from 2kN to 600 kN) (Temperatures ambient to 800°C) BS EN ISO 6892-2 BS EN 2002-2 ASTM E21 CON Fracture Toughness: CTOD and K1c (in the

View lab

Westmoreland Mechanical Testing & Research

Banbury, GB

HoldsPart 1Part 2Part 005
Scope

EN 2002-005; ISO 204 Stress Rupture ASTM E139, E292; ISO 204 Metallurgical Tests Depth of Decarburization (Micro Hardness and Optical Techniques) ASTM E1077 Average Grain Size ASTM E112 (comparison method), E1382 (semi-auto

View lab

Element Materials Technology Sheffield Ltd, Trading as Element Materials Technology Sheffield – Magna Way

South Yorkshire, GB

HoldsPart 1Part 2
Scope

EN 2002-1 ASTM A370 ASTM E8/E8M ASTM B557/B557M Tensile: (Elevated temperature from ambient to 950°C) (forces from 0.2 kN to 250 kN) BS EN ISO 6892-2 BS EN 2002-2 ASTM E21 Proof and Tensile strength (temperature - ambi

View lab

Wallwork Cambridge

Cambridge, GB

HoldsPart 1
Scope

EN 2002-1:2005 ASTM E8/E8M-24 Impact Izod Impact Testing BS 131 Part 1 1961 END

View lab

Swansea Materials Research and Testing

Swansea, GB

HoldsPart 1Part 2Part 005
Scope

EN 2002-1:2005 (Forces up to 100 kN) (Temperature range ambient to 900 °C) BS EN ISO 6892-2:2018 BS EN 2002-2:2005 Creep and Stress Rupture: Creep (Temperature range ambient to 1150 °C) (not including constant stre

View lab

Element Materials Technology Aerospace UK Limited, Trading as Element Materials Technology

Lancaster, GB

HoldsPart 1Part 2
Scope

EN 2002-2 LAN Forces 0.2 kN up to 400 kN Sub-Zero Temperature -1960C and -1000C to ambient BS EN ISO 6892-3 LAN Through thickness tensile BS EN 10164 ASTM A770/A770M MID Pipe and Pipeline Components Ring fl

View lab

Forged Solutions Testing part of Forged Solutions Group

Derbyshire, GB

We don't know yet whether this lab takes outside work.
HoldsPart 1Part 2Part 005
Scope

EN 2002-1 ASTM A370 ASTM E8/E8M Tensile (temperatures up to 900°C) (forces from 1.25kN to 250kN) BS EN ISO 6892-2 BS EN 2002-2 ASTM E21 Stress Rupture (temperature up to 900°C) Creep (temperature 300°C to 900°C)

View lab

KNDS DEFENCE UK

Greater Manchester, GB

We don't know yet whether this lab takes outside work.
HoldsPart 1
Scope

EN 2002-1:2005 Vickers hardness (HV5, HV10) BS EN ISO 6507-1:2023 Metallurgical Tests Average Grain size Using Leica DM2700 microscope ASTM E112-24 ASTM E1382-97(2023) by semiautomatic and automatic imag

View lab

Howmet

Devon, GB

We don't know yet whether this lab takes outside work.
HoldsPart 2Part 005
Scope

EN 2002-005:2007 ASTM E139-11(2018) BS EN ISO 204:2023 Tensile tests Ambient Temperature (Range 0.1 - 50kN) Elevated Temperature (650 °C and 850 °C) Excluding the determination of Young’s Modulus BS EN ISO 68

View lab

Mettis Aerospace

Redditch, GB

We don't know yet whether this lab takes outside work.
HoldsPart 1
Scope

EN 2002-1 ASTM E8/E8M ASTM B557 ASTM A370 Izod Impact testing BS 131 Part 1 Charpy Impact (ambient Temperature) V-notch and U-Notch BS EN ISO 148-1 Fracture toughness (K1C & JC) ASTM E399 ASTM B645 ASTM B646 BS 7448

View lab

Independent Forgings and Alloys Ltd – Technology Centre

Sheffield, GB

We don't know yet whether this lab takes outside work.
HoldsPart 1Part 2
Scope

EN 2002-1:2005 ASTM A370-24 ASTM E8/E8M-24 Tensile (Temperature range 300 to 800ºC) (Forces up to 100 kN) BS EN ISO 6892-2:2018 BS EN 2002-2:2005 ASTM E21-20 Stress Rupture Plain and notched stress rupture (Temperatu

View lab

Airbus Operations

Bristol, GB

We don't know yet whether this lab takes outside work.
HoldsPart 1
Scope

EN 2002-1:2005 LT.01.02.12 Phenolic Mouldings, Reinforced Laminates, Phenolic Epoxy and Polyester, and Rubbers Tension (Up to 2500kN) AITM 1-0007 Issue 5 LT.01.02.12 Bearing Stress / Strength (Up to 2500kN) AITM 1-0009 Issu

View lab

Speciality Steel UK

South Yorkshire, GB

We don't know yet whether this lab takes outside work.
HoldsPart 1
Scope

EN 2002-1:2005 RRMS 30020 Rev E A Tensile (Ambient temperature) (Forces from 0.5 kN to 600 kN) ISO 6892-1:2019 ASTM A370-24 ASTM E8/E8M-24 BS 4A 4: Pt1 Sect 1 1966 BS EN 2002-1:2005 B METALS, ALLOYS and METAL PROD

View lab

About ISO/IEC 17025 in United Kingdom

United Kingdom Accreditation Service (UKAS) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United Kingdom.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.

Related searches