ISO 140 Accredited Testing Labs Worldwide
ISO 140, all parts: Acoustics - Measurement of sound insulation in buildings and of building elements. Each lab card shows which parts it holds.
- ISO 140-3Part 3: Laboratory measurements of airborne sound insulation of building elements3 labs →
- ISO 140-4Part 4: Field measurements of airborne sound insulation between rooms48 labs →
- ISO 140-5Part 5: Field measurements of airborne sound insulation of façade elements and façades19 labs →
- ISO 140-6Part 6: Laboratory measurements of impact sound insulation of floors4 labs →
- ISO 140-7Part 7: Field measurements of impact sound insulation of floors44 labs →
- ISO 140-8Part 8: Laboratory measurements of the reduction of transmitted impact noise by floor coverings on a heavyweight standard floor3 labs →
- ISO 140-14Part 14: Guidelines for special situations in the field3 labs →
- ISO 140-18Part 18: Laboratory measurement of sound generated by rainfall on building elements1 lab →
51 accredited laboratories in 4 countries hold ISO 140 in their accredited scope. We don't know yet whether 21 of them take outside work. Primary accreditors include United Kingdom Accreditation Service, Entidad Nacional de Acreditación, Polish Centre for Accreditation.
Available in 4 Countries
Sample labs
ISO 140-4:1998 (Withdrawn) BS EN ISO 717-1:1997 (Withdrawn) Site 100 Hz to 5 KHz BS EN ISO 16283-1:2014 + A1:2017 BS EN ISO 717-1:2020 Site
ISO 140-4:1998 BS EN ISO 717-1:1997 Site Floors Field measurement of impact sound insulation of floors between rooms, ie Impact Sound Pressure Level and related factors Sound insulation tests including pre-completion testing
ISO 140-14:2004 EN ISO 140-14:2004 DIN EN ISO 140- 14:2004+B1:2009 Acoustics – Measurement of sound insulation in buildings and of building elements – Part 14: Guidelines for special situations in the field N ISO 3382-1:2009
ISO 140-4:1998 (Withdrawn) BS EN ISO 717-1:1997 (Withdrawn) BS EN ISO 16283-1:2014 +A1:2017 BS EN ISO 717-1:2020 A Floors Field measurement of impact sound insulation of floors Sound insulation tests including pre-complet
ISO 140-4:2000 PN-EN ISO 16283-1:2014-05 z wyłączeniem punktu 7.4 PN-EN ISO 16283-1:2014/A1:2018-02 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06 Wskaźnik ważony izolacyjności akustycznej właściwej przybliżonej R’w, i wskaźnik
ISO 140-4:1998 (Withdrawn) BS EN ISO 717-1:1997 (Withdrawn) Sound Insulation tests including pre- completion testing for dwellings and rooms for residential purpose for The Building Regulations 2010. Approved Document E (2003 Editio
ISO 140-4:1998 (Withdrawn) BS EN ISO 717-1:1997 (Withdrawn) Sound Insulation tests including pre- completion testing for dwellings and rooms for residential purpose for The Building Regulations 2010. Approved Document E (2003 Edition
ISO 140-4:1998 (Withdrawn) BS EN ISO 717-1:1997 (Withdrawn) Site Floors Field measurement of impact sound insulation of floors between rooms, ie, Impact Sound Pressure Level and related factor Sound insulation tests including
ISO 140-4:1998 BS EN ISO 16283-1:2014 BS EN ISO 717-1:1997
ISO 140-4:1998 (Withdrawn) BS EN ISO 717-1:1997 (Withdrawn) Building Bulletin 93:2003 (Withdrawn) HTM 08-01 Site Floors Field measurement of impact sound insulation of floors between rooms, ie Impact Sound Pressure Level and
ISO 140-4:1998 ISO 140-4:1998 BS EN ISO 717-1:2020 ISO 717-1:2020 B FLOORS Field measurement of impact sound insulation of floors between rooms, ie Impact sound pressure level and related factors
ISO 140-4:2000 PN-EN ISO 16283-1:2014-05 z wyłączeniem pkt. 7.4 PN-EN ISO 16283-1:2014-05/ A1:2018-02 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06 Poziom uderzeniowy znormalizowany L’n, i poziom uderzeniowy wzorcowy
ISO 140-4:2000 PN-EN ISO 140-14:2006 Wskaźnik ważony znormalizowanej różnicy poziomów Dn,w, wzorcowej różnicy poziomów DnT,W, i izolacyjności akustycznej właściwej przybliżonej R’w, oraz widmowe wskaźniki adaptacyjne C i Ctr (z obl
ISO 140-4:1998 (Withdrawn) BS EN ISO 16283-1:2014 + A1,2017 BS EN ISO 717-1:1997 (Withdrawn) BS EN ISO 717-1:2013 (Withdrawn) BS EN ISO 717-1:2020 Site Building (Scotland) Regulations 2004. Technical Handbook (Dom
ISO 140-4:1999 UNE-EN ISO 16283-1 I Medida de aislamiento acústico al ruido aéreo de fachadas ( Método global del altavoz. Procedimiento con posiciones de micrófono fijas) UNE-EN ISO 140-5:1999 UNE-EN ISO 16283-3 I Medida de aisla
ISO 140-18:2006
ISO 140-4:1998 BS EN ISO 717-1:1997 Site Floors Field measurement of impact sound insulation of floors between rooms, i.e. Impact Sound Pressure Level and related factors Sound insulation tests including pre-completion testing
ISO 140-4:1999 UNE-EN ISO 16283-1 Medida del aislamiento acústico al ruido aéreo de fachadas (Método global del altavoz. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 140-5:1999 UNE-EN ISO 16283-3 Medida de
ISO 140-4:1999 Medidas de aislamiento acústico de suelos al ruido de impactos (Método con máquina de impactos). UNE-EN ISO 16283-2 UNE-EN ISO 140-7:1999 Medidas de aislamiento acústico al ruido aéreo de fachadas (Método global de alta
ISO 140-4:1998 (Withdrawn) BS EN ISO 16283- 1:2014+A1:2017 BS EN ISO 16283-3:2016 BS EN ISO 717-1:1997 (Withdrawn) BS EN ISO 717-1:2020 Building Bulletin 93 Feb 2015 Site
ISO 140-4:1998 (Withdrawn) BS EN ISO 717-1:1997 (Withdrawn) 50 Hz – 5 KHz Building Bulletin 93 – Version 17 Feb 2015 Tables 3a & 3b 50 Hz – 5 KHz HTM 08-01 - 2013 50 Hz – 5 KHz BS EN ISO 16283-1:2014+A1:2017 BS EN ISO
ISO 140-4:1998 ISO 140-4:1998 BS EN ISO 16283-1:2014 + A1:2017 B FLOORS Field measurement of impact sound insulation of floors Sound insulation tests including pre-completion testing for dwellings and rooms for residentia
ISO 140-4:1998 ISO 140-4:1998 BS EN ISO 717-1:1997 ISO 717-1:1996 A Floors Field measurement of impact sound insulation of floors between rooms, i.e. Impact Sound Pressure Level and related factors Sound insulation tests incl
ISO 140-4 PN-EN ISO 16283-1 Maszyny i urządzenia emitujące hałas do otoczenia E Machines and devices emitting noise to the environment E Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A Poziom ciśni
ISO 140-4:1998 (Withdrawn) BS EN ISO 717- 1:1997(Withdrawn) Site 50 Hz to 5 KHz BS EN ISO 16283-1:2014 BS EN ISO 717-1:2013 Site Floors Field measurement of impact sound insulation of floors between rooms, i.e. Impact
ISO 140-4:1998 (Withdrawn) BS EN ISO 717-1:1997 (Withdrawn) Site Floors Field measurement of impact sound insulation of floors between rooms, ie Impact Sound Pressure Level and related factors Sound insulation tests including
ISO 140-4:1999 Medida del aislamiento acústico de suelos a ruido de impactos (Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-2 UNE-EN ISO 140-7:1999 Medida de aislamiento acústico al ruido aéreo de facha
ISO 140-4:1998 (Withdrawn) BS EN ISO 717-1:1997 (Withdrawn) Site Floors Field measurement of impact sound insulation of floors between rooms, i.e. Impact Sound Pressure Level and related factors Sound insulation tests includ
ISO 140-3:1995 A Mechanical Tests PLYWOOD Glue bond strength BS EN 314-1:2004 A DOWEL TYPE FASTENERS FOR STRUCTURAL Withdrawal capacity BS EN 1382:2016 A TIMBER (dowels, nails, Head pull through BS EN 1383:201
ISO 140:Part 6:1998 (Withdrawn) BS EN ISO 717-2:1997 (Withdrawn) A Laboratory measurement of airborne and impact sound insulation of building elements BS EN ISO 10140-2:2021 BS EN ISO 717-1:2020 BS EN ISO 10140-3:2021 BS EN
ISO 140 -4 1998-12 Akustik - Messung der Schalldämmung in Gebäuden und von Bauteilen - Teil 4: Messung der Luftschalldämmung zwischen Räumen in Gebäuden (zurückgezogene Norm) DIN EN ISO 140 -5 1998-12 + Berichtigung 1 2008-1
ISO 140-8:1999 Pomieszczenia w budynku (wszystkie) Poziom dźwięku (w budynku) Zakres: (22 - 137) dB in situ PN-87/B-02156 (bez p.6.3) Stropy Izolacyjność od dźwięków powietrznych elementów budowlanych Zakres częstotliwości: (100 -
ISO 140-4:1998 (Withdrawn) Site FLOORS Field measurements of impact sound insulation of floors Sound insulation tests including pre-completion testing for dwellings and rooms for residential purpose for The Building Regulati
ISO 140-4:1999 UNE-EN ISO 16283-1 Nota: El laboratorio mantiene un listado controlado y público de los Documentos Normativos que ha analizado y para los que ha concluido que dispone de la adecuada capacidad técnica. ENAC es firmante
ISO 140-4:2000 PN-EN ISO 16283-1:2014 z wyłączeniem punktów 7.4 i 7.5 PN-EN ISO 16283-1/A1:2018-02 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2013-08 PN-EN ISO 717-1:2021-06 Izolacyjność akustyczna od dźwięków powietrznych między pomie
ISO 140-4:1999 Medida del aislamiento acústico de suelos al ruido de impactos (Método con máquina de impactos. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-2 UNE-EN ISO 140-7:1999 Medida del aislamien
ISO 140-4:1998 ISO 140-14:2004/Cor 1:2007 ISO 140-14:2004 ISO 717-1:2020 RTY Suositus äänieristävyyden mittaamisesta 21.9.2009 Helsinki, Riika, Tallinna, Vilna, Kenttätoimintaa Julkisivut Julkisivujen ilmaäänieristävyyden kenttämittaukset j
ISO 140-4:1999 Medición del aislamiento acústico al ruido aéreo de fachadas (Método global del altavoz) UNE-EN ISO 16283-3 UNE-EN ISO 140-5:1999 Medida del aislamiento acústico de suelos al ruido de impactos UNE-EN ISO 140-7:1999
ISO 140-4:1998 (Withdrawn) ISO 140-4:1998 (Withdrawn) BS EN ISO 16283-1:2014 + A1:2017 A
ISO 140-4:1999 UNE-EN ISO 16283-1 Medida del aislamiento acústico de suelos al ruido de impactos (Método con máquina de impactos. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 140-7:1999 UNE-EN ISO 16283-2
ISO 140-4:2000 PN-EN ISO 16283-1:2014-05 z wyłączeniem p. 7.4 PN-EN ISO 16283-1:2014-05 /A1:2018-02 Wskaźnik ważony izolacyjności akustycznej właściwej przybliżonej R’w, i wskaźnik ważony wzorcowej różnicy poziomów DnT,w, oraz wid
ISO 140-4:1999 UNE-EN ISO 16283-1 Medida del aislamiento acústico al ruido aéreo de fachadas (Método global del altavoz, Método global con ruido de tráfico. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 140
ISO 140-4:2000 PN-EN ISO 16283-1:2014-05E + PN-EN ISO 16283-1:2014-05/A1:2018- 02 z wyłaczeniem punktu 13 Wskaźnik ważony znormalizowanej różnicy poziomów Dn,w, wzorcowej różnicy poziomów DnT,W, i izolacyjności akustycznej właściwej
ISO 140-4:1999 Medida del aislamiento acústico de suelos al ruido de impactos (Método con máquina de impactos. Procedimiento por defecto con posiciones de micrófono fijas) UNE-EN ISO 16283-2 UNE-EN ISO 140-7:1999 Medida del aislamie
ISO 140-4:1999 Medida del aislamiento acústico de suelo a ruido de impactos (Método con máquina de impactos. Procedimiento por defecto con posiciones de micrófono fijas) UNE EN ISO 16283-2 UNE EN ISO 140-7:1999 Medida de aislamie
ISO 140-4:2000 z wyłączeniem Załącznika C PN-EN ISO 16283-1:2014-05 z wyłączeniem punktu 7.4 PN-EN ISO 16283-1:2014- 05/A1:2018-02 Wskaźnik ważony izolacyjności akustycznej właściwej przybliżonej R’w, Wskaźnik ważony wzorcowej ró
ISO 140-6:1999 Wskaźnik ważony poziomu uderzeniowego znormalizowanego Ln,w oraz widmowy wskaźnik adaptacyjny CI (z obliczeń) Weighted normalised impact sound pressure level Ln,w and spectrum adaptation term CI (calculated) PN-EN I
ISO 140-7:1998 (Withdrawn) BS EN ISO 717-2:1997 (Withdrawn) Site
ISO 140-4:1999 Medida del aislamiento acústico de suelos al ruido de impactos (Procedimiento por defecto con posiciones fijas de micrófono y máquina de impactos) UNE-EN ISO 16283-2 UNE-EN ISO 140-7:1999 Medidas del aislamiento acústic
ISO 140-4:2000 PN-EN ISO 16283-1:2014-05 z wyłączeniem p. 7.4 PN-EN ISO 16283-1:2014-05 /A1:2018-02 PN-EN ISO 717-1:1999 PN-EN ISO 717-1:2021-06 Przybliżony poziom uderzeniowy znormalizowany L’n, i poziom uderzeniowy wzorco
Showing labs 1–50 of 51. Use pagination below to see more.