FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
ISO/IEC 17025 directory · Standard series

IEC 62133 Accredited Testing Labs in Germany

IEC 62133, all parts13 laboratories in Germany are accredited by DAKKS for at least one part of IEC 62133. Each lab card shows which parts it holds. From the accredited scope text: “IEC 62133+Corr.1 2013-06 Akkumulatoren und Batterien mit alkalischen oder anderen nicht säurehaltigen Elektrolyten - Sicherheitsanforderungen für tragbare gasdichte Akkumulatoren und daraus hergestell” “IEC 62133 -1: 2017 SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON-ACID ELECTROLYTES - SAFETY REQUIREMENTS FOR PORTABLE SEALED SECONDARY CELLS, AND FOR BATTERIES MADE FROM THEM, FOR USE” “IEC 62133- 2:2017); German version EN 62133-2:2017 DIN EN IEC 62619; VDE 051 0-39 2020-05 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for sec”

Labs
13
Primary AB
DAKKS13 labs
Parts of this series

Accredited Labs

TÜV Rheinland LGA Products

Nürnberg, DE

HoldsPart 2
Scope

IEC 62133+Corr.1 2013-06 Akkumulatoren und Batterien mit alkalischen oder anderen nicht säurehaltigen Elektrolyten - Sicherheitsanforderungen für tragbare gasdichte Akkumulatoren und daraus hergestellte Batterien für die Verwendung in

View lab

TÜV Rheinland Japan Ltd. Yokohama Laboratories Global Technology Assessment Center

Japan, DE

HoldsPart 1Part 2
Scope

IEC 62133 -1:2017 EN 62133-1:2017 DIN EN 62133-1 :2017 VDE 0510-81:2017- 11:2017 Secondary cells and baNeries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for baNe

View lab

VDE Prüf- und Zertifizierungsinstitut

Offenbach am Main, DE

HoldsPart 1Part 2
Scope

IEC 62133:2012 DIN EN 62133 (VDE 0510-8):2013 EN 62133:2013 Akkumulatoren und Batterien mit alkalischen oder anderen nicht säurehaltigen Elektrolyten - Sicherheitsanforderungen für tragbare Gasdichte Akkumulatoren und daraus hergest

View lab

CSA Group Bayern

Plattling, DE

HoldsPart 1Part 2
Scope

IEC 62133 -1: 2017 SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON-ACID ELECTROLYTES - SAFETY REQUIREMENTS FOR PORTABLE SEALED SECONDARY CELLS, AND FOR BATTERIES MADE FROM THEM, FOR USE IN PORTABLE APPLICATIONS - PART 1

View lab

TÜV Rheinland Japan Ltd. Kansai Technology Center Osaka

Japan, DE

HoldsPart 1
Scope

IEC 62133 -1:2017 EN 62133-1:2017 DIN EN 62133-1 VDE 0510-81:2017-11 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries ma

View lab

TÜV SÜD Product Service

Frankfurt/Main, DE

HoldsPart not stated on the certificate
Scope

IEC 62133:2013 Akkumulatoren und Batterien mit alkalischen oder anderen nicht säurehaltigen Elektrolyten - Sicherheitsanforderungen für tragbare gasdichte Akkumulatoren und daraus hergestellte Batterien für die Verwendung in tragba

View lab

Intertek Deutschland

Kaufbeuren, DE

HoldsPart 1Part 2
Scope

IEC 62133-1:2017 Secondary cells and batteri es containing alkaline and other non-acid electrolytes – Safety requirements for portable sealed secondary cells and for batteries made from them, for the use in portable applications – Part

View lab

SGS Germany

Puchheim, DE

HoldsPart 1Part 2
Scope

IEC 62133-1: 2017 Secondary cells and batteries con taining alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 1:

View lab

cetecom advanced

Saarbrücken, DE

HoldsPart 1Part 2
Scope

IEC 62133:2012); German version EN 62133:2013 ☐ ESS ☒ SB SAF IEC 62133:2012 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batte

View lab

TÜV SÜD Battery Testing

Garching b. München, DE

HoldsPart 1Part 2
Scope

IEC 62133 -1 2017-02 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part

View lab

Industrieanlagen- Betriebsgesellschaft mit beschränkter Haftung

Lichtenau, DE

HoldsPart 2
Scope

IEC 62133- 2:2017); German version EN 62133-2:2017 DIN EN IEC 62619; VDE 051 0-39 2020-05 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and bat

View lab

SLG Prüf- und Zertifizierungs

Hartmannsdorf, DE

HoldsPart 1Part 2
Scope

IEC 62133:2002 EN 62133:2003 DIN EN 62133:2003 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use

View lab

Kiwa Primara

Kaufbeuren, DE

HoldsPart 1Part 2
Scope

IEC 62133:2012 EN 62133:2013 DIN EN 62133:2013 VDE 0510-81:2013 Akkumulatoren und Batterien mit alkalischen oder anderen nicht säurehaltigen Elektrolyten - Sicherheitsanforderungen für tragbare gasdichte Akkumulatoren und daraus

View lab
Refine these results

This page is a fixed slice of the register: every IEC 62133 scope we hold for Germany. Search narrows it further by city, accreditation body, or a term from the scope text itself.

Search labs in Germany

Top matrices for IEC 62133 in Germany

Top analytes for IEC 62133 in Germany

  • Frequency1
  • Isolation Resistance1

About ISO/IEC 17025 in Germany

Deutsche Akkreditierungsstelle (DAKKS) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in Germany.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.