Registers refreshed 2026-11-20.See refresh dates
Accredited lab directory

IEC 61000-4-4 Accredited Testing Labs in Netherlands

7 laboratories in Netherlands are accredited by RvA to perform IEC 61000-4-4 testing. We don't know yet whether 2 of them take outside work. From the accredited scope text: “IEC 61000-4-4 A. EMC. I.23 Electric and electronic equipment Surge Immunity, 1-phase up to 10,0 kV 3-phase up to 4,0 kV EN/IEC 61000-4-5 A.” “IEC 61000-4-4 EMC.I.23 Surge Immunity 1 to 3 phase 0-32A 0 – 5.0 kV EMC-02-TSD-015-WIN EN 61000-4-5 IEC 61000-4-5 EMC.I.24 Power frequency magnetic field Immunity 50/60 Hz 1 – 30 A/m EMC-02-TSD-017-WI” “IEC 61000-4-4 EMC.I.23 Surge immunity 1 and 3 phases 0,25 – 8 kV EN-IEC 60255-26 EN-IEC 62052-11 EN 50470-1 OIML R46 EN-IEC 61000-4-5 EMC.I.07 Immunity to conducted disturbances, induced by radio-freq” “IEC 61000-4-4, 2004/104/EC, 97/24/EC, ECE Regulation 10 HE, MoLo EMC.I.23 Electrical and electronic equipment, Motor vehicles and electronic subassemblies (ESA) Surge Immunity 3 phase max 32 A ±4 kV I”

Labs
7
Primary AB
RvA7 labs

Accredited Labs

BICON Laboratories B.V.

HELMOND, NL

Scope

IEC 61000-4-4, 2004/104/EC, 97/24/EC, ECE Regulation 10 HE, MoLo EMC.I.23 Electrical and electronic equipment, Motor vehicles and electronic subassemblies (ESA) Surge Immunity 3 phase max 32 A ±4 kV IS Conducted Susceptibility

View lab

KEMA B.V.

ARNHEM, NL

Scope

IEC 61000-4-4 EMC.I.23 Surge immunity 1 and 3 phases 0,25 – 8 kV EN-IEC 60255-26 EN-IEC 62052-11 EN 50470-1 OIML R46 EN-IEC 61000-4-5 EMC.I.07 Immunity to conducted disturbances, induced by radio-frequency fields 3 V - 10 V

View lab

DEKRA Certification

ARNHEM, NL

Scope

IEC 61000-4-4 A. EMC. I.23 Electric and electronic equipment Surge Immunity, 1-phase up to 10,0 kV 3-phase up to 4,0 kV EN/IEC 61000-4-5 A.

View lab

Kiwa Assurance

RIJSWIJK ZH, NL

Scope

EN / IEC 61000-4-4 WO, OS EMC.I.23 Surge Immunity 3 phase 32A Up to 4 kV document 874 EN / IEC 61000-4-5 WO, OS EMC.I.24 Power frequency magnetic field Immunity 50/60 Hz Up to 30 A/m document 1829 EN / IEC 61000-4-8 WO EMC

View lab

Kiwa Nederland

RIJSWIJK ZH, NL

Scope

Normative document: EN ISO/IEC 17025:2017 Registration number: L 015 of Kiwa Nederland B.V. Kiwa FSS Testing This annex is valid from: 29-01-2026 to 01-09-2028 Replaces annex dated: 28-01-2026 Dutch Accreditation Council RvA

View lab

Signify Netherlands

EINDHOVEN, NL

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-4 EMC.I.23 Surge Immunity 1 to 3 phase 0-32A 0 – 5.0 kV EMC-02-TSD-015-WIN EN 61000-4-5 IEC 61000-4-5 EMC.I.24 Power frequency magnetic field Immunity 50/60 Hz 1 – 30 A/m EMC-02-TSD-017-WIN EN 61000-4-8 I

View lab

Thales Nederland

HENGELO OV, NL

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-4 HE EMC.I.23 Surge Immunity 0.5 – 2 kV EN-IEC 61000-4-5 HE EMC.I.24 Power frequency magnetic field Immunity 1 – 100 A/m 50 / 60 Hz EN-IEC 61000-4-8 HE

View lab

About ISO/IEC 17025 in Netherlands

Dutch Accreditation Council (RvA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in Netherlands.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.