Konica Minolta Sensing Americas
101 Williams Drive, 07446, Ramsey, NJ, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 4673.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | CIE 127:2007 | - | See scope document |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4673.01) 3/11/2026 Page 3 of 3
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Spectral Irradiance3 –
[Spectroradiometer]
(370 to 1100) nm
(370 to 390) nm
(400 to 430) nm
(440 to 990) nm
(1000 to 1050) nm
(1060 to 1100) nm
4.0 %
2.7 %
2.4 %
4.0 %
4.6 %
Spectral intensity standard
(lamp), distance standard
(end rod)
Spectral Radiance3 –
[Spectroradiometer]
(380 to 1040) nm
(380 to 390) nm
(400 to 540) nm
(550 to 1040) nm
4.7 %
3.6 %
3.1 %
Spectral radiance standard
(integrating sphere light
source)
_______________________________
1 This laboratory offers commercial calibration service for Konica Minolta and Instrument Systems
equipment only.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be
considered and this, on its own, could result in the actual measurement uncertainty achievable on a
customer’s site being larger than the CMC.
4 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | 370 to 1100 nm |
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- AALFA - KAL Metrology Laboratory, division of AALBORG Instruments & ControlsOrangeburg, NY · ~13 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Atlantic Scale CompanyNutley, NJ · ~28 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Newark, NJBoonton, NJ · ~28 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Instru-Met CorporationUnion, NJ · ~46 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- CONNECTICUT CALIBRATION TECHNOLOGIES, INC., dba CONNECTICUT CALIBRATIONNewtown, CT · ~80 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.