FLW Service Corporation
5672 Bolsa Ave., 92649, Huntington Beach, CA, United States
Visit website- Scope lines
- 13
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 13 scope lines.
A2LA certificate 3449.01 · 13 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3449.01) 09/19/2025 Page 2 of 12
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Current – Measure
(0 to 100) µA
(0 to 1.0) mA
(0 to 10) mA
(0 to 100) mA
(0 to 1.0) A
39 µA/A + 0.81 nA
35 µA/A + 5.1 nA
37 µA/A + 51 nA
89 µA/A + 0.51 µA
0.023 % + 10 µA
Keysight 3458A,
option 002
Resistance – Generate
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
74 µΩ/Ω + 0.0010 Ω
41 µΩ/Ω + 0.0015 Ω
35 µΩ/Ω + 0.0014 Ω
35 µΩ/Ω + 0.0020 Ω
34 µΩ/Ω + 0.0020 Ω
35 µΩ/Ω + 0.020 Ω
34 µΩ/Ω + 0.020 Ω
37 µΩ/Ω + 0.20 Ω
35 µΩ/Ω + 0.20 Ω
42 µΩ/Ω + 2.0 Ω
41 µΩ/Ω + 2.0 Ω
136 µΩ/Ω + 30 Ω
0.037 % + 50 kΩ
0.15 % + 2.5 kΩ
1.37 % + 3.0 kΩ
0.41 % + 0.10 MΩ
2.0 % + 0.50 MΩ
Fluke 5522A
Resistance – Measure
(0 to 10) Ω
(10 to 100) Ω
(0.10 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.10 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
26 µΩ/Ω + 60 µΩ
21 µΩ/Ω + 0.60 mΩ
16 µΩ/Ω + 0.60 mΩ
16 µΩ/Ω + 6.0 mΩ
16 µΩ/Ω + 60 mΩ
25 µΩ/Ω + 3.0 Ω
88 µΩ/Ω + 0.12 kΩ
0.085 % + 1.0 kΩ
Keysight 3458A,
option 002 | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3449.01) 09/19/2025 Page 3 of 12
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1000) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.10 % + 6.0 µV
0.038 % + 6.0 µV
0.046 % + 6.0 µV
0.16 % + 6.0 µV
0.50 % + 12 µV
1.15 % + 50 µV
0.060 % + 8.0 µV
0.041 % + 8.0 µV
0.050 % + 8.0 µV
0.13 % + 8.0 µV
0.32 % + 32 µV
0.73 % + 70 µV
0.059 % + 50 µV
0.034 % + 60 µV
0.050 % + 60 µV
0.13 % + 50 µV
0.33 % + 0.13 mV
0.75 % + 0.60 mV
0.059 % + 0.65 mV
0.024 % + 0.60 mV
0.035 % + 0.60 mV
0.086 % + 0.60 mV
0.27 % + 1.6 mV
0.025 % + 2.0 mV
0.048 % + 6.0 mV
0.058 % + 6.0 mV
0.16 % + 6.0 mV
0.23 % + 50 mV
0.047 % + 10 mV
0.041 % + 10 mV
0.052 % + 10 mV
Fluke 5522A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3449.01) 09/19/2025 Page 4 of 12
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure
(0 to 10) mV
(10 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
100 kHz to 1 MHz
(1 to 4) MHz
(4 to 8) MHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
0.035 % + 2.3 µV
0.053 % + 2.3 µV
0.16 % + 2.3 µV
0.83 % + 2.3 µV
6.4 % + 2.8 µV
23.5 % + 5.4 µV
11.4 % + 7.3 µV
32 % + 8.2 µV
0.014 % + 2.0 µV
0.028 % + 2.0 µV
0.051 % + 2.0 µV
0.26 % + 2.0 µV
0.63 % + 10 µV
1.7 % + 10 µV
6.5 % + 70 µV
6.6 % + 80 µV
24 % + 0.10 mV
0.014 % + 20 µV
0.028 % + 20 µV
0.051 % + 20 µV
0.26 % + 20 µV
0.63 % + 0.10 mV
1.7 % + 0.10 mV
6.5 % + 0.70 mV
6.6 % + 0.80 mV
24 % + 1.0 mV
0.030 % + 0.40 mV
0.013 % + 0.20 mV
0.025 % + 0.20 mV
0.083 % + 0.20 mV
0.26 % + 0.20 mV
1.7 % + 1.0 mV
5.4 % + 1.0 mV
8.0 % + 1.0 mV
6.5 % + 7.0 mV
6.5 % + 8.0 mV
24 % + 10 mV
0.033 % + 2.0 mV
0.040 % + 2.0 mV
0.10 % + 2.0 mV
0.31 % + 2.0 mV
0.69 % + 10 mV
Keysight 3458A,
option 002 | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3449.01) 09/19/2025 Page 5 of 12
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure
(cont)
(100 to 700) V
40 Hz to 1 kHz
(1 to 20) kHz
0.068 % + 20 mV
0.10 % + 20 mV
Keysight 3458A,
option 002
AC Current – Generate
(30 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.22 % + 0.10 µA
0.16 % + 0.10 µA
0.14 % + 0.10 µA
0.33 % + 0.15 µA
1.2 % + 0.20 µA
1.9 % + 0.40 µA
0.22 % + 0.15 µA
0.14 % + 0.15 µA
0.11 % + 0.15 µA
0.22 % + 0.20 µA
0.55 % + 0.30 µA
1.1 % + 0.60 µA
0.20 % + 2.0 µA
0.10 % + 2.0 µA
0.044 % + 2.0 µA
0.088 % + 2.0 µA
0.22 % + 3.0 µA
0.46 % + 4.0 µA
0.20 % + 20 µA
0.10 % + 20 µA
0.044 % + 20 µA
0.11 % + 50 µA
0.22 % + 0.10 mA
0.44 % + 0.20 mA
0.21 % + 0.10 mA
0.061` % + 0.10 mA
0.66 % + 1.0 mA
2.7 % + 5.0 mA
Fluke 5522A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3449.01) 09/19/2025 Page 6 of 12
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate
(cont)
(1 to 3) A
(3 to 11) A
(11 to 20) A
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
8.06 % + 0.10 mA
7.76 % + 0.10 mA
3.46 % + 1.0 mA
10.9 % + 5.0 mA
0.22 % + 2.0 mA
0.24 % + 2.0 mA
3.3 % + 2.0 mA
0.15 % + 5.0 mA
0.19 % + 5.0 mA
3.3 % + 5.0 mA
Fluke 5522A
AC Current – Measure
(0 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
100 Hz to 5 kHz
100 Hz to 5 kHz
100 Hz to 5 kHz
100 Hz to 5 kHz
100 Hz to 5 kHz
0.10 % + 30 nA
0.052 % + 0.20 µA
0.052 % + 2.0 µA
0.051 % + 20 µA
0.16 % + 0.20 mA
Keysight 3458A,
option 002 | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3449.01) 09/19/2025 Page 7 of 12
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouples –
Generate and Measure
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.55 °C
0.18 °C
0.15 °C
0.18 °C
0.23 °C
0.30 °C
0.18 °C
0.16 °C
0.19 °C
0.26 °C
0.37 °C
0.20 °C
0.18 °C
0.29 °C
0.44 °C
0.44 °C
0.24 °C
0.21 °C
0.20 °C
0.30 °C
0.63 °C
0.36 °C
0.17 °C
0.44 °C
0.52 °C
0.40 °C
0.41 °C
0.51 °C
0.69 °C
0.26 °C
0.18 °C
0.15 °C
Fluke 5522A | ||
| 8 | AMS 2750 | - | See scope document |
| 9 | AMS2750 | - | See scope document |
| 10 | AMS 2750 | Ovens, Furnaces, Autoclaves, Freezers, Incubators, and Environmental Chambers3 | See scope document |
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3449.01) 09/19/2025 Page 11 of 12
Parameter/Equipment
Range
CMC2, 6, 7 (±)
Comments
Temperature – Measure
(-39 to 0) °C
0 °C
(0 to 232) °C
(232 to 420) °C
0.016 °C
0.017 °C
0.030 °C
0.030 °C
Fluke 1502A w/
Isotech T100-450
Temperature – Measuring
Equipment
(-25 to 0) °C
0 °C
(0 to 80) °C
(40 to 232) °C
(232 to 420) °C
25 °C
0.16 °C
0.16 °C
0.19 °C
0.50 °C
0.50 °C
0.28 °C
Fluke 1502A & Isotech
T100-450 w/ Kaye LTR-
50
Fluke 1502A & Isotech
T100-450 w/ Wika
CTD9100
Dewtrak II/DX/AT
hygrometer w/ Tenney
UTRC-W4F-C
environmental chamber
Relative Humidity –
Measuring Equipment
(20 to 50) % RH
50 % RH
(50 to 70) % RH
0.78 % RH
0.80 % RH
0.85 % RH
Dewtrak II/DX/AT
hygrometer w/ Tenney
UTRC-W4F-C
environmental
chamber
________________________________
1 This laboratory offers commercial laboratory and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC. | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3449.01) 09/19/2025 Page 12 of 12
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as eit her a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 In the statement of CMC, the percentage value is defined as the percentage of reading.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 13 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Anko ElectronicsAnaheim, CA · ~19 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Element U.S. Space & DefenseFullerton, CA · ~22 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- RSA Industries Inc dba American GagePlacentia, CA · ~25 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994