Endress+Hauser Flow USA
2330 Endress Place, 46143, Greenwood, IN, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 1897.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1897.01) 01/28/2026 Page 2 of 3
Parameter/Equipment
Range
CMC2 (±) Comments
Flowrate3 (cont) –
Flowrig FCP 6.21
Mass
Volume
Flowrig FCP 6.H
Mass
Volume
Flowrig FCP 7.1.B
Mass
Volume
Mass
Volume
Flowrig FCP 7.1.F
Mass
Volume
Mass
Volume
(0.0005 to 0.022) kg/s
(0.022 to 0.35) kg/s footnote4
(0.2 to 11.2) kg/s footnote4
(0.001 to 0.067) kg/s
(0.067 to 11.2) kg/s
(0.0005 to 0.022) l/s
(0.022 to 0.35) l/s footnote4
(0.2 to 11.2) l/s footnote4
(0.001 to 0.067) l/s
(0.067 to 11.2) l/s
(0.001 to 11.9) kg/s
(0.001 to 11.9) l/s
(0.2 to 200) kg/s
(0.2 to 200) l/s
(0.2 to 200) kg/s
(0.2 to 200) l/s
(0.07 to 200) kg/s footnote4
(0.07 to 200) l/s footnote4
(0.2 to 200) kg/s
(0.2 to 200) l/s
0.046 % of rdg
0.021 % of rdg
0.014 % of rdg
0.061 % of rdg
0.047 % of rdg
0.044 % of rdg
0.018 % of rdg
0.017 % of rdg
0.061 % of rdg
0.047 % of rdg
0.047 % of rdg
0.056 % of rdg
0.051 % of rdg
0.056 % of rdg
0.062 % of rdg
0.066 % of rdg
0.015 % of rdg
0.020 % of rdg
0.058 % of rdg
0.062 % of rdg
Gravimetric flow rig with
volumetric prover
Volumetric
Gravimetric
Gravimetric (master)
Volumetric
Gravimetric
Gravimetric (master)
Gravimetric flow rig with
volumetric prover
Gravimetric flow rig
Gravimetric (master
meters)
Gravimetric flow rig
Gravimetric (master
meters) | ||
| 3 | - | WaterShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1897.01) 01/28/2026 Page 3 of 3
Parameter/Equipment Range CMC2 (±) Comments
Flowrate3 (cont) –
Flowrig FCP 9.B
Volume
(19 to 710) l/s
0.076 % of rdg
Volumetric flow rig with
master meters
Density (Water) –DCP
8.A
(80 to 65) °C
(<65 to 45) °C
(<45 to 25) °C
(<25 to 5) °C
(970 to 980) kg/m3
(>980 to 990) kg/m3
(>990 to 997) kg/m3
(>997 to 1001) kg/m3
0.20 kg/m3
0.14 kg/m3
0.088 kg/m3
0.058 kg/m3
Comparison – water
density within density
calibration rig
__________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The CMC claim is smaller than that of the expanded uncertainty claim for The National Institute of
Standards and Technology (NIST) as listed in the BIPM Key Comparison Database. A2LA has evaluated
the laboratory’s CMC claim and has verified this information to be correct and appropriate.
4 The CMC for this Parameter/Equipment applies for performance verification of the “best existing” device
under test and not for the assignment of reference values, and therefore certain characteristics of the “best
existing” device under test (e.g. repeatability) are not included in this CMC estimate.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | See scope document |
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Endress+HauserGreenwood, IN · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Magnetic InstrumentationIndianapolis, IN · ~18 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Quality Control Sales and ServicesIndianapolis, IN · ~18 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Radian ResearchLafayette, IN · ~112 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Tektronix, Inc. - CincinnatiCincinnati, OH · ~149 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.