Registers refreshed 2026-11-08.See refresh dates
United States

Mettler-Toledo, LLC dba Johnson Scale & Balance

36 Stiles Lane, 07058, Pine Brook, NJ, United States

Visit website
A2LA 7068.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
7
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 7 scope lines.

A2LA certificate 7068.01 · 7 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2ASTM Class 1 weights-See scope document
3ASTM Class 1; ASTM Class 6; NIST Class F-See scope document
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7068.01) Revised 10/21/2025 Page 4 of 6 Parameter/Equipment Range CMC2, 4 (±) Comments Force3 – Measuring Equipment Deadweight 0.1 lbf 0.2 lbf 0.25 lbf 0.5 lbf 0.75 lbf 1 lbf 2.5 lbf 5 lbf 7.5 lbf 10 lbf 20 lbf 0.5 lbf 1 lbf 2 lbf 3 lbf 4 lbf 5 lbf 6 lbf 7 lbf 8 lbf 9 lbf 10 lbf 11 lbf 12 lbf 13 lbf 14 lbf 15 lbf 16 lbf 17 lbf 18 lbf 19 lbf 20 lbf 0.000 024 lbf 0.000 047 lbf 0.000 29 lbf 0.000 12 lbf 0.000 41 lbf 0.000 18 lbf 0.000 30 lbf 0.000 58 lbf 0.000 87 lbf 0.0012 lbf 0.0023 lbf 0.000 42 lbf 0.000 72 lbf 0.0012 lbf 0.0019 lbf 0.0023 lbf 0.0020 lbf 0.0027 lbf 0.0031 lbf 0.0038 lbf 0.0042 lbf 0.0034 lbf 0.0041 lbf 0.0045 lbf 0.0052 lbf 0.0056 lbf 0.0054 lbf 0.0061 lbf 0.0065 lbf 0.0072 lbf 0.0076 lbf 0.0068 lbf Test stand w/ deadweights: Class F weights Class 7 weights
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7068.01) Revised 10/21/2025 Page 5 of 6 Parameter/Equipment Range CMC2, 4 (±) Comments Force3 – Measuring Equipment (cont) Deadweight 20 lbf 40 lbf 50 lbf 60 lbf 70 lbf 80 lbf 90 lbf 100 lbf 110 lbf 120 lbf 130 lbf 140 lbf 150 lbf 160 lbf 170 lbf 180 lbf 190 lbf 200 lbf 210 lbf 220 lbf 230 lbf 240 lbf 250 lbf 260 lbf 270 lbf 280 lbf 290 lbf 300 lbf 310 lbf 320 lbf 330 lbf 340 lbf 350 lbf 360 lbf 370 lbf 380 lbf 390 lbf 400 lbf 410 lbf 420 lbf 430 lbf 440 lbf 450 lbf 460 lbf 470 lbf 480 lbf 490 lbf 500 lbf 0.0024 lbf 0.0047 lbf 0.0058 lbf 0.0071 lbf 0.0082 lbf 0.0094 lbf 0.011 lbf 0.012 lbf 0.013 lbf 0.014 lbf 0.016 lbf 0.017 lbf 0.018 lbf 0.019 lbf 0.020 lbf 0.021 lbf 0.022 lbf 0.024 lbf 0.025 lbf 0.026 lbf 0.027 lbf 0.028 lbf 0.029 lbf 0.031 lbf 0.032 lbf 0.033 lbf 0.034 lbf 0.035 lbf 0.036 lbf 0.037 lbf 0.039 lbf 0.040 lbf 0.041 lbf 0.042 lbf 0.043 lbf 0.044 lbf 0.046 lbf 0.047 lbf 0.048 lbf 0.049 lbf 0.050 lbf 0.051 lbf 0.052 lbf 0.054 lbf 0.055 lbf 0.056 lbf 0.057 lbf 0.058 lbf Test stand w/ deadweights: Class 6 Weights
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7068.01) Revised 10/21/2025 Page 6 of 6 Parameter/Equipment Range CMC2 (±) Comments Torque3 – Analyzers (0.015 625 to 0.5) lbf∙in (0.25 to 8) ozf∙in (0.625 to 4) lbf∙in (10 to 64) ozf∙in (5 to 260) lbf∙in (240 to 3000) lbf∙in 0.023 % + 0.000 002 4 lbf·in 0.018 % + 0.000 033 lbf·in 0.012 % + 0.000 17 lbf·in 0.012 % + 0.0018 lbf·in Test stand w/ torque wheel & deadweights Test stand w/ torque arm & deadweights ____________________________________________ 1 This laboratory offers commercial calibration service and field calibration service, where noted. 2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the be havior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This Scope meets A2LA’s P112 Flexible Scope Policy.
7ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

36 Stiles Lane, Pine Brook, NJ, 07058, US

40.86629, -74.34165

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.