United States

Illiana Instrumentation Service

1831 Govert Dr, 46375, Schererville, IN, United States

Visit website
A2LA 2230.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
8
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 8 scope lines.

A2LA certificate 2230.01 · 8 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2230.01) 10/21/2024 Page 2 of 7 Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage3 – Measure (0 to 10) mV (0 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 600) V 4.3 µV 8.8 µV 49 µV 0.52 mV 5.8 mV 18 mV HP 34401A DC Current3 – Generate (0 to 20) mA (20 to 100) mA 2.1 µA 31 µA Fluke 525B DC Current3 – Measure (0 to 10) mA (10 to 100) mA 100 mA to 1 A (1 to 3) A 0.01 mA 18 µA 2.4 mA 4.8 mA HP 34401A Resistance3 – Measure (0 to 25) Ω 100 Ω (25 to 400) Ω (400 to 1000) Ω (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 1.6 mΩ 4.2 mΩ 16 mΩ 0.1 Ω 1.2 Ω 12 Ω 0.11 kΩ 4.1 kΩ 1.1 % of rdg Hart 1560 & 2562 Fluke 525B, HP 34401A Resistance3 – Generate Fixed Point (0 to 5) Ω (5 to 400) Ω (400 to 4000) Ω (4 to 11) kΩ 100 Ω 38 mΩ 21 mΩ 0.30 Ω 8.9 Ω 6.4 mΩ Fluke 744 Fluke 525B Fluke 744 IET SRA-100
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2230.01) 10/21/2024 Page 3 of 7 Parameter/Equipment Range CMC2, 4 (±) Comments Electrical Calibration of Thermocouple Indicators3 – Measure & Simulate Type B Type C Type E Type J Type K Type L Type N Type R Type S Type T (600 to 1820) °C (0 to 1800) °C (1800 to 2316) °C (-270 to -100) °C (-100 to 1820) °C (-210 to 1200) °C (-200 to 1372) °C (-200 to 800) °C (-270 to 1320) °C (-50 to 250) °C (250 to 1767) °C (0 to 250) °C (250 to 1750) °C (-270 to -150) °C (-150 to 400) °C 0.42 °C 0.27 °C 0.41 °C 0.15 °C 0.09 °C 0.11 °C 0.14 °C 0.1 °C 0.16 °C 0.52 °C 0.34 °C 0.51 °C 0.38 °C 0.29 °C 0.10 °C Fluke 525B Fluke 525B, ice point Electrical Calibration of RTD 3 – Measure & Generate Pt 385, 100 Ω (-200 to -80) οC (-80 to 100) οC (100 to 400) οC (400 to 800) οC 56 m οC 58 mοC 60 mοC 0.081 οC Fluke 525B
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2230.01) 10/21/2024 Page 4 of 7 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure (1 to 100) mV (1 to 600) V (10 to 20) kHz 10 Hz to 20 kHz 0.14 mV 0.69 V HP 34401A AC Current – Measure (0 to 1) A (1 to 3) A 10 Hz to 5 kHz 10 Hz to 5 kHz 2.8 mA 5.9 mA HP 34401A III. Fluid Quantities Parameter/Equipment Range CMC2 (±) Comments Viscosity – Cups: Ford Fisher Zahn NK2 (19 to 880) cP (2, 3, 4, 5) Cups (1, 2, 3, 4) Cups (1, 2, 3, 4, 5) Cups (19 to 880) cP 2 Cups 1.7 % of rdg 1.7 % of rdg 1.7 % of rdg 1.7 % of rdg 1.7 % of rdg 1.7 % of rdg Certified viscosity oil IV. Mechanical Parameter/Equipment Range CMC2, 6 (±) Comments Pressure3 – Measure & Measuring Equipment (-1 to 1) psig (3 to 15) psig (-10 to 200) psig (200 to 1500) psig (1500 to 2850) psig 0.0012 psi 0.024 psi 0.12 psi 0.63 psi 2.0 psi Fluke 718 Fluke module 700P24 Fluke module 700PD7 Fluke module 700P09 Beta module PI-03K
5AMS2750-See scope document
6AMS 2750-See scope document
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2230.01) 10/21/2024 Page 7 of 7 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The measurands stated are generated using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure the measuran d in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction/percent of the reading plus a fixed floor specification. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
8ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1831 Govert Dr, Schererville, IN, 46375, US

41.47892, -87.45476

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.