Hapeman Electronics
496 Billy Boyd Road, 16153, Stoneboro, PA, United States
Visit website- Scope lines
- 7
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 7 scope lines.
A2LA certificate 6493.01 · 7 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6493.01) 12/3/2025 Page 2 of 6
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Current – Measure3
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
120 µA/A + 800 pA
53 µA/A + 5.0 nA
51 µA/A + 50 nA
64 µA/A + 500 nA
120 µA/A + 10 µA
HP 3458A
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate3
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
640 µV/V + 6.0 µV
180 µV/V + 6.0 µV
200 µV/V + 6.0 µV
800 µV/V + 6.0 µV
2.7 mV/V + 12 µV
6.3 mV/V + 50 µV
240 µV/V + 8.0 µV
120 µV/V + 8.0 µV
130 µV/V + 8.0 µV
280 µV/V + 8.0 µV
630 µV/V + 32 µV
1.6 mV/V + 70 µV
240 µV/V + 50 µV
120 µV/V + 60 µV
150 µV/V + 60 µV
240 µV/V + 50 µV
550 µV/V + 130 µV
1.9 mV/V + 600 µV
240 µV/V + 650 µV
120 µV/V + 600 µV
190 µV/V + 600 µV
280 µV/V + 600 µV
710 µV/V + 1.6 mV
160 µV/V + 2.0 mV
160 µV/V + 6.0 mV
200 µV/V + 6.0 mV
280 µV/V + 6.0 mV
1.6 mV/V + 50 mV
250 µV/V + 10 mV
210 µV/V + 10 mV
Fluke 5522A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6493.01) 12/3/2025 Page 3 of 6
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure3
(0 to 10) mV
(10 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
40 Hz to 1 kHz
(1 to 20) kHz
310 µV/V + 3.0 µV
250 µV/V + 1.1 µV
300 µV/V + 1.1 µV
800 µV/V + 1.1 µV
3.9 mV/V + 1.1 µV
32 mV/V + 2.0 µV
190 µV/V + 4.0 µV
190 µV/V + 2.0 µV
210 µV/V + 2.0 µV
300 µV/V + 2.0 µV
650 µV/V + 2.0 µV
2.3 mV/V + 10 µV
90 µV/V + 40 µV
90 µV/V + 20 µV
130 µV/V + 20 µV
240 µV/V + 20 µV
630 µV/V + 20 µV
2.3 mV/V + 100 µV
180 µV/V + 400 µV
90 µV/V + 200 µV
130 µV/V + 200 µV
240 µV/V + 200 µV
670 µV/V + 200 µV
2.3 mV/V + 1.0 mV
170 µV/V + 2.0 mV
170 µV/V + 2.0 mV
280 µV/V + 2.0 mV
940 µV/V + 2.0 mV
320 µV/V + 20 mV
470 µV/V + 20 mV
HP 3458A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6493.01) 12/3/2025 Page 4 of 6
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate3
(29 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
1.6 mA/A + 100 nA
1.2 mA/A + 100 nA
970 µA/A + 100 nA
2.3 mA/A + 150 nA
6.2 mA/A + 200 nA
12 mA/A + 400 nA
1.6 mA/A + 150 nA
970 µA/A + 150 nA
780 µA/A + 150 nA
1.6 mA/A + 200 nA
3.9 mA/A + 300 nA
7.8 mA/A + 600 nA
1.4 mA/A + 2.0 µA
700 µA/A + 2.0 µA
310 µA/A + 2.0 µA
620 µA/A + 2.0 µA
1.6 mA/A + 3.0 µA
3.1 mA/A + 4.0 µA
1.4 mA/A + 20 µA
710 µA/A + 20 µA
310 µA/A + 20 µA
780 µA/A + 50 µA
1.6 mA/A + 100 µA
3.1 mA/A + 200 µA
1.4 mA/A + 100 µA
390 µA/A + 100 µA
4.7 mA/A + 1.0 mA
19 mA/A + 5.0 mA
1.4 mA/A + 100 µA
490 µA/A + 100 µA
4.7 mA/A + 1.0 mA
19 mA/A + 5.0 mA
540 µA/A + 2.0 mA
790 µA/A + 2.0 mA
23 mA/A + 2.0 mA
Fluke 5522A (Lcomp
OFF) | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6493.01) 12/3/2025 Page 5 of 6
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Measure3
(0 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
100 Hz to 5 kHz
(5 to 20) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
3.1 mA/A + 30 nA
1.2 mA/A + 30 nA
510 µA/A + 30 nA
510 µA/A + 30 nA
3.1 mA/A + 200 nA
1.2 mA/A + 200 nA
490 µA/A + 200 nA
270 µA/A + 200 nA
490 µA/A + 200 nA
3.1 mA/A + 2.0 µA
1.2 mA/A + 2.0 µA
490 µA/A + 2.0 µA
270 µA/A + 2.0 µA
490 µA/A + 2.0 µA
3.1 mA/A + 20 µA
1.2 mA/A + 20 µA
480 µA/A + 20 µA
260 µA/A + 20 µA
480 µA/A + 20 µA
3.1 mA/A + 200 µA
1.3 mA/A + 200 µA
680 µA/A + 200 µA
820 µA/A + 200 µA
HP 3458A
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance – Generate3
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
330 Ω to 1.1 kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
53 µΩ/Ω + 1.0 mΩ
47 µΩ/Ω + 1.5 mΩ
28 µΩ/Ω + 1.4 mΩ
25 µΩ/Ω + 2.0 mΩ
11 mΩ/Ω + 2.0 mΩ
25 µΩ/Ω + 20 mΩ
25 µΩ/Ω + 20 mΩ
25 µΩ/Ω + 200 mΩ
24 µΩ/Ω + 200 mΩ
25 µΩ/Ω + 2.0 Ω
Fluke 5522A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6493.01) 12/3/2025 Page 6 of 6
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance – Generate
(cont.)3
330 kΩ to 1.1 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
35 µΩ/Ω + 2.0 Ω
47 µΩ/Ω + 30 Ω
100 µΩ/Ω + 50 Ω
190 µΩ/Ω + 2.5 kΩ
390 µΩ/Ω + 3.0 kΩ
2.3 mΩ/Ω + 100 kΩ
12 mΩ/Ω + 500 kΩ
Fluke 5522A
Resistance – Measure3
(1 to 10) Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
27 µΩ/Ω + 50 µΩ
18 µΩ/Ω + 500 µΩ
13 µΩ/Ω + 500 µΩ
12 µΩ/Ω + 5.0 mΩ
13 µΩ/Ω + 50 mΩ
19 µΩ/Ω + 2.0 Ω
50 µΩ/Ω + 100 Ω
HP 3458A
________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 7 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Instrument Calibration SolutionsAliquippa, PA · ~82 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Ohm-LabsPittsburgh, PA · ~100 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Process InstrumentsPittsburgh, PA · ~100 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- All American Scales & CalibrationParis, OH · ~107 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Micro Laboratories, Inc.Mentor, OH · ~109 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.