Fluke Calibration, Phoenix - Primary Pressure and Flow

4765 East Beautiful Lane, 85044, Phoenix, AZ, United States

A2LA 1599.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 1599.01 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1599.01) Revised 03/09/2026 Page 2 of 4 III. Mechanical Parameter/Equipment Range CMC2, 4, 6 (±) Comments Mass – Measure Nominal Values All Values (2, 3.2, 4.0, 4.5, 5.0, 6.2, 6.4, 10.0, 10.1) kg (0.8, 1.0, 1.6) kg (0.1, 0.2, 0.3, 0.4, 0.5) kg 1 mg to 12 kg 0.0001 % 0.000 13 % 0.0002 % 0.0005 % or 0.5 mg, whichever is greater True mass determinations for use with piston gauges Pressure – Gas Effective Area of Piston – Cylinder Calibration of Secondary Standards & Pressure Devices (5 to 500) kPa (500 to 1000) kPa (1000 to 5000) kPa (5000 to 11 000) kPa (11 to 20) MPa (20 to 50) MPa (50 to 100) MPa (0 to 15) kPa (5 to 500) kPa (500 to 1000) kPa (1000 to 5000) kPa (5000 to 11 000) kPa (11 to 110) MPa (-15 to 15) kPa (-90 to 550) kPa (-990 to 990) kPa (-50 to 50) MPa 0.000 56 % 0.000 65 % 0.000 76 % 0.000 77 % 0.0012 % 0.0013 % 0.0015 % 0.0025 % + 8 mPa 0.0009 % + 0.05 Pa 0.0010 % 0.0012 % 0.0014 % 0.0023 % |0.0025 %| + 5 mPa |0.001 %| + 0.3 Pa 0.0014 % + (0.1 Pa + 0.000 13 % x LP) 0.0035 % + (0.000 13 % x LP) From the Fluke calibration piston- cylinder pressure calibration chain Absolute Absolute & gauge Gauge Differential mode line pressure from -90 kPa to 550 kPa HL differential: LP (line pressure) range: (10 to 1000) kPA Line pressure range: (1 to 100) MPa
3-Oil
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1599.01) Revised 03/09/2026 Page 3 of 4 Parameter/Equipment Range CMC2, 4 (±) Comments Pressure – Oil Effective Area of Piston Cylinder Calibration of Secondary Standards & Pressure Devices (0.2 to 50) MPa (50 to 100) MPa (100 to 200) MPa (200 to 500) MPa (0.1 to 20) MPa (20 to 100) MPa (100 to 200) MPa (200 to 500) MPa (500 to 700) MPa 0.0013 % 0.0015 % 0.0022 % 0.003 % 0.0017 % + 14 Pa 0.002 % 0.003 % 0.0047 % 0.03 % From the Fluke calibration piston- cylinder pressure calibration chain Gauge & absolute Pressure – Oil Calibration of Secondary Standards & Pressure Devices 3 (0.1 to 20) MPa (20 to 50) MPa (50 to 70) MPa (70 to 140) MPa (140 to 200) MPa (200 to 350) MPa (350 to 500) MPa 0.0018 % + 14 Pa 0.0023 % 0.0025 % 0.0033 % 0.0038 % 0.0055 % 0.0075 % Gauge & absolute Calibration of Pressure Devices 3 – Gas (0 to 133) Pa (1.4 to 5) kPa (5 to 550) kPa (5 to 550) kPa (550 to 2750) kPa (550 to 2750) kPa (2750 to 11 000) kPa (11 to 20) MPa (20 to 50) MPa (50 to 103) MPa (-7.5 to 7.5) kPa (-1.4 to -100) kPa 0.5 % + 0.15 Pa 0.0015 % + 1 Pa 0.0015 % + 0.01 Pa 0.0015 % + 0.2 Pa 0.0017 % 0.0017 % + 0.2 Pa 0.0017 % 0.0019 % 0.0027 % 0.0038 % |0.006 %| + 0.07 Pa |0.0015 %| + 0.05 Pa Gauge & absolute (except where noted) Absolute; using capacitance diaphragm pressure transducer Absolute Gauge Absolute Gauge Absolute Differential; using quartz bourdon tube pressure transducer Negative gauge
See scope document
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1599.01) Revised 03/09/2026 Page 4 of 4 IV. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Measure & Measuring Equipment (15 to 30) °C 0.03 °C Fluke thermistor Relative Humidity – Measure & Measuring Equipment (5 to 95) % RH 3 % RH Vaisala humidity probe V. Time & Frequency Parameter/Equipment Frequency CMC 2, 4, 6 (±) Comments Frequency – Measure 1000 Hz 0.0008 % HP 53131A __________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentages are to be read as percent of reading, unless indicated otherwise. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
15 to 30 °C
5ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

4765 East Beautiful Lane, Phoenix, AZ, 85044, US

33.44844, -112.07414

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.