United States

Dickson

930 South Westwood Ave., 60101, Addison, IL, United States

Visit website
A2LA 1621.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 1621.01 · 3 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 1621.01) 08/13/2025 Page 2 of 2 III. Thermodynamics Parameter/Equipment Range CMC2, 4 (±) Comments Relative Humidity – Measure (5 to 95) % RH at (15 to 35) °C (10 to 95) % RH at (5 to 50) °C 0.50 % RH 3 % RH Chilled mirror standards Chamber with relative humidity instrument Resistance Thermometry – Measuring Equipment Fixed Points (-120 to 360) °F (-84 to 182) °C (-80 to 0) °C (-30 to 150) °C 0 °C -196 °C 0.15 °F 0.08 °C 0.07 °C 0.06 °C 0.05 °C 0.4 °C Chamber with platinum RTD Alcohol bath and platinum RTD Silicone oil bath and platinum RTD Ice bath and platinum RTD Liquid nitrogen bath and platinum RTD Thermocouple Temperature Simulation – Type K (-320 to 2000) °F 0.87 °F Thermocouple simulator ___________________________________________ 1 This laboratory offers commercial calibration service for Dickson and Oceasoft products only. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 In the statement of CMC, percentage (%) refers to percent of reading, unless otherwise noted.
3ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

930 South Westwood Ave., Addison, IL, 60101, US

41.93170, -87.98896

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.