Dickson
930 South Westwood Ave., 60101, Addison, IL, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 1621.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 1621.01) 08/13/2025 Page 2 of 2
III. Thermodynamics
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Relative Humidity –
Measure
(5 to 95) % RH
at (15 to 35) °C
(10 to 95) % RH
at (5 to 50) °C
0.50 % RH
3 % RH
Chilled mirror standards
Chamber with relative
humidity instrument
Resistance Thermometry –
Measuring Equipment
Fixed Points
(-120 to 360) °F
(-84 to 182) °C
(-80 to 0) °C
(-30 to 150) °C
0 °C
-196 °C
0.15 °F
0.08 °C
0.07 °C
0.06 °C
0.05 °C
0.4 °C
Chamber with platinum
RTD
Alcohol bath and
platinum RTD
Silicone oil bath and
platinum RTD
Ice bath and platinum
RTD
Liquid nitrogen bath and
platinum RTD
Thermocouple Temperature
Simulation –
Type K
(-320 to 2000) °F
0.87 °F
Thermocouple simulator
___________________________________________
1 This laboratory offers commercial calibration service for Dickson and Oceasoft products only.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 In the statement of CMC, percentage (%) refers to percent of reading, unless otherwise noted. | ||
| 3 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Florida Metrology, LLC d/b/a Acme MetrologyVilla Park, IL · ~5 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- GraftelRoselle, IL · ~10 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Chicago, ILArlington Heights, IL · ~17 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- J. H. MetrologyRolling Meadows, IL · ~17 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - ChicagoNaperville, IL · ~22 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.