Registers refreshed 2026-11-20.See refresh dates
United States

SIMCO Electronics - Dayton

800 Pleasant Valley Drive, 45066, Springboro, OH, United States

Visit website
A2LA 1395.02ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
16
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 16 scope lines.

A2LA certificate 1395.02 · 16 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 1 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.02) 08/22/2025 Page 2 of 15 Parameter/Equipment Range CMC2, 4 (±) Comments Surface Roughness – Roughness Average (Patch) (13 to 120) µin 8.6 µin Mitutoyo SJ-410 Surface Roughness Tester 3 µm, 0.35 µm, & 0.4 µm (1.2 % of value + 0.017) µm Roughness patch Micrometers3 – Linearity Flatness Parallelism Up to 36 in Up to 1 in Up to 0.001 in (36 + 4.2L) µin 5.6 µin 5.6 µin Gage blocks Optical flat Optical parallel Height Gages3 Up to 40 in (120 + 4.2L) µin Gage blocks w/ surface plate Depth Gages3 Up to 12 in (120 + 4.2L) µin Gage blocks w/ surface plate Feeler Gages & Thickness Specimens Up to 1 in (20 + 1.5L) µin Zeiss ULM w/ Gage blocks Calipers3 Up to 40 in (90 + 4.2L) µin Gage blocks / cal kit Cylinders - Plug Gages, Pin Gages & Master Setting Discs (0.01 to 4) in (14 + 2.2L) µin Zeiss ULM w/ Gage blocks Surface Plates3 – Overall Flatness (12 to 60) in 78 µin Planekator Optical Flats – Flatness Up to 4 in Diameter 4.2 µin Van Keuren 12 in optical flat
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.02) 08/22/2025 Page 3 of 15 Parameter/Equipment Range CMC2, 4 (±) Comments Angle Meters & Protractors (0 to 90)° 0.03° + 0.6R Gage blocks & sine bar II. Dimensional Testing/Calibration1 Parameter/Equipment Range CMC2, 4 (±) Comments Length – 1D6 Up to 4 in (> 4 to 12) in (12 + 2.2L) µin (20 + 2.5L) µin Zeiss ULM w/ gage blocks III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Generate3 (0 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1000) V 41 µV/V + 1 µV 11 µV/V + 2 µV 11 µV/V + 20 µV 26 µV/V + 0.15 mV 16 µV/V + 1.5 mV Fluke 5520A/SC600 DC Voltage – Measure3 (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 9.3 µV/V + 0.3 µV 7.9 µV/V + 0.3 µV 7.1 µV/V + 0.5 µV 9.4 µV/V + 30 µV 9.4 µV/V + 0.1 mV* HP 3458A opt-2 *Add 12(V in/1000)2 µV/V to all Vin > 100
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.02) 08/22/2025 Page 4 of 15 Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC High Voltage – Measure3 (1 to 90) kV 0.12 % + 0.000 014 V Ross Engineering VD90-16.5Y-AK-KB- AL, Fluke 87V DC Current – Generate3 (0 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20) A (20 to 100) A 0.013 % + 0.02 µA 0.0093 % + 0.05 µA 0.0092 % + 0.25 µA 0.0094 % + 2.5 µA 0.017 % + 40 µA 0.03 % + 40 µA 0.039 % + 500 µA 0.08 % + 750 µA 0.11 % + 10 mA Fluke 5520A/SC600 Valhalla 2555A DC Current – Measure3 (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 24 µA/A + 5 nA 25 µA/A + 50 nA 42 µA/A + 0.50 µA 140 µA/A + 1 µA HP 3458A opt-2 DC Current – Clamp on Meters & Current Transformers3 (10 to 25) A (25 to 150) A (150 to 1025) A 0.62 % + 0.02 A 0.62 % + 0.14 A 0.62 % + 0.5 A Fluke 5520A/SC600, Fluke 5500A/coil, HP 3458A OPT-2 DC Current Shunts3 (1 to 10) mΩ, Up to 100 A 0.032 % HP 3458A opt-2 w/ Valhalla 2555A DC Power – Generate 33 mV to 1020 V: (0.33 to 329.99) mA (0.33 to 2.9999) A (3 to 20.5) A (0.01 to 330) W (0.33 to 3.3) kW (3.3 to 20.5) kW 0.019 % + 0.000 58 W 0.013 % + 0.2 W 0.046 % + 2.9 W Fluke 5520A/SC600 Resistance – Measure3 (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (100 to 1000) MΩ 35 µΩ/Ω + 50 µΩ 22 µΩ/Ω + 0.5 mΩ 16 µΩ/Ω + 0.5 mΩ 16 µΩ/Ω + 5.0 mΩ 16 µΩ/Ω + 50 mΩ 21 µΩ/Ω + 2 Ω 83 µΩ/Ω + 100 Ω 0.06 % + 1 kΩ 0.61 % + 10 kΩ HP 3458A opt-2
to 90 kV
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.02) 08/22/2025 Page 5 of 15 Parameter/Equipment Range CMC2, 5 (±) Comments Resistance – Generate3 (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (0.33 to 1.1) GΩ 0.0083 % + 1.0 mΩ 0.006 % + 1.5 mΩ 32 µΩ/Ω + 1.4 mΩ 25 µΩ/Ω + 2.0 mΩ 28 µΩ/Ω + 2.0 mΩ 26 µΩ/Ω + 0.02 Ω 26 µΩ/Ω + 0.02 Ω 26 µΩ/Ω + 0.2 Ω 26 µΩ/Ω + 0.2 Ω 36 µΩ/Ω + 2 Ω 34 µΩ/Ω + 2 Ω 0.0078 % + 30 Ω 0.014 % + 50 Ω 0.024 % + 2.5 kΩ 0.053 % + 3 kΩ 0.24 % + 0.10 MΩ 1.2 % + 0.50 MΩ Fluke 5520A Oscilloscopes3 – Level Sine Amp: 50 kHz Ref Level Sine Flatness: 5 mV to 5.5 V Relative to 50 kHz Reference Bandwidth DC Signal Level Time Marker Output Into 50 Ω Pulse Rise Time: 10 MHz 1 MHz Square Wave – Generate 50 Ω (0.01 to 10) kHz 1 MΩ (0.01 to 1) kHz 1 MΩ (1 to 10) kHz Edge Transition Time 10 mV to 5 V(p-p) 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz Up to 130 V Up to 6.6 V 2 ns to 20 ms 50 ms to 5 s 0.5 V, 1 V (p-p) 1 V (p-p) 1 mV to 6.6 V(p-p) 1 mV to 130 V(p-p) 1 mV to 130 V(p-p) (200 to 350) ps 1 kHz to 10 MHz 2.3 % + 300 µV 2.3 % + 100 µV 2.9 % + 100 µV 4.9 % + 100 µV 0.06 % + 40 µV 0.29 % + 40 µV 3 parts in 10 6 (29 + 1000t) µs/s 160 ps 160 ps 0.29 % + 40 µV 0.14 % + 40 µV 0.29 % + 40 µV 120 ps Fluke 5520A/SC600 Into 1 MΩ load Into 50 Ω load Fluke 5520A/SC600 t = time in seconds
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.02) 08/22/2025 Page 6 of 15 Parameter/Equipment Range CMC2, 5 (±) Comments Capacitance – Generate3 (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 0.7) mF 0.39 % + 10 pF 0.60 % + 10 pF 0.63 % + 10 pF 0.27 % + 10 pF 0.26 % + 0.1 nF 0.24 % + 0.1 nF 0.29 % + 0.3 nF 0.24 % + 1.0 nF 0.20 % + 3.0 nF 0.21 % + 10 nF 0.33 % + 30 nF 0.43 % + 0.1 µF 0.36 % + 0.3 µF 0.36 % + 1.0 µF Fluke 5520A Electrical Simulation of Thermocouples – Generate/Measure3 Type E Type J Type K Type S Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.58 °C 0.19 °C 0.17 °C 0.19 °C 0.25 °C 0.32 °C 0.32 °C 0.18 °C 0.22 °C 0.28 °C 0.39 °C 0.22 °C 0.20 °C 0.31 °C 0.47 °C 0.55 °C 0.42 °C 0.44 °C 0.54 °C 0.74 °C 0.30 °C 0.21 °C 0.19 °C Fluke 5520A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.02) 08/22/2025 Page 7 of 15 Parameter/Equipment Range CMC2, 5 (±) Comments Electrical Calibration of RTD Indicating Devices3 – Pt 385, 100 Ω (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.064 °C 0.063 °C 0.086 °C 0.11 °C 0.12 °C 0.15 °C 0.27 °C Fluke 5520A Parameter/Range Frequency CMC2, 5 (±) Comments Phase Angle – Generate3 3.0 V/ 0.5 V (All at 0°) (10 to 65) Hz (65 to 400) Hz 400 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.21 ° 0.21 ° 0.30 ° 0.21 ° 0.28 ° 0.28 ° Fluke 5520A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.02) 08/22/2025 Page 8 of 15 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate3 (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.087 % + 6 µV 0.052 % + 6 µV 0.042 % + 6 µV 0.11 % + 6 µV 0.29 % + 12 µV 0.67 % + 50 µV 0.024 % + 8 µV 0.012 % + 8 µV 0.014 % + 8 µV 0.029 % + 8 µV 0.063 % + 32 µV 0.16 % + 70 µV 0.024 % + 50 µV 0.013 % + 60 µV 0.016 % + 60 µV 0.024 % + 50 µV 0.056 % + 0.13 mV 0.19 % + 0.60 mV 0.024 % + 0.65 mV 0.013 % + 0.6 mV 0.019 % + 0.6 mV 0.028 % + 0.6 mV 0.071 % + 1.6 mV 0.016 % + 2 mV 0.017 % + 6 mV 0.020 % + 6 mV 0.028 % + 6 mV 0.16 % + 50 mV 0.024 % + 10 mV 0.020 % + 10 mV 0.024 % + 10 mV Fluke 5520A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.02) 08/22/2025 Page 9 of 15 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Measure3 (1 to 10) mV (10 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 700) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.07 % + 3.0 µV 0.06 % + 1.1 µV 0.06 % + 1.1 µV 0.14 % + 1.1 µV 0.58 % + 1.1 µV 4.6 % + 2.0 µV 0.02 % + 4.0 µV 0.01 % + 2.0 µV 0.018 % + 2.0 µV 0.038 % + 2.0 µV 0.094 % + 2.0 µV 0.35 % + 10 µV 1.2 % + 10 µV 0.0084 % + 40 µV 0.0085 % + 20 µV 0.017 % + 20 µV 0.036 % + 20 µV 0.093 % + 20 µV 0.35 % + 0.10 mV 1.2 % + 0.10 mV 0.013 % + 0.40 mV 0.0084 % + 0.20 mV 0.017 % + 0.20 mV 0.035 % + 0.20 mV 0.093 % + 0.20 mV 0.36 % + 1.0 mV 1.2 % + 1.0 mV 0.024 % + 4.0 mV 0.024 % + 2.0 mV 0.024 % + 2.0 mV 0.041 % + 2.0 mV 0.14 % + 2.0 mV 0.47 % + 10 mV 0.05 % + 40 mV 0.05 % + 20 mV 0.07 % + 20 mV 0.14 % + 20 mV 0.35 % + 20 mV HP 3458A opt-2 AC High Voltage3 – Measure @ 60 Hz (1 to 60) kV 0.0058 V/V + 0.000 043 V Ross Engineering VD90-16.5Y-AK- KB-AL, Fluke 87V
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.02) 08/22/2025 Page 10 of 15 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Generate3 (29 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3.0) A (3.0 to 11.0) A (11.0 to 20.5) A (20 to 100) A (45 to 1000) Hz (45 to 1000) Hz (> 1 to 5) kHz (45 to 1000) Hz (> 1 to 5) kHz (45 to 1000) Hz (> 1 to 5) kHz (45 to 1000) Hz (> 1 to 5) kHz (45 to 1000) Hz (> 1 to 5) kHz (45 to 1000) Hz (> 1 to 5) kHz (45 to 1000) Hz (> 1 to 5) kHz (45 to 1000) Hz 0.13 % + 0.10 µA 0.042 % + 0.15 µA 0.16 % + 0.20 µA 0.042 % + 2 µA 0.068 % + 2 µA 0.053 % + 20 µA 0.089 % + 50 µA 0.041 % + 0.1 mA 0.47 % + 1.0 mA* 0.079 % + 0.1 mA 0.47 % + 1.0 mA* 0.095 % + 2.0 mA 2.3 % + 2.0 mA 0.13 % + 5.0 mA 2.4 % + 5.0 mA 0.79 % + 0.082 A Fluke 5520A/SC600 *For compliance voltages >1V, add 1mA/V to floor specification Valhalla 2555A AC Current – Measure3 (5 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (45 to 1000) Hz (45 to 1000) Hz (0.1 to 5) kHz (45 to 1000) Hz (0.1 to 5) kHz (45 to 1000) Hz (0.1 to 5) kHz (45 to 1000) Hz (0.1 to 5) kHz 0.073 % + 30 nA 0.071 % + 200 nA 0.036 % + 200 nA 0.070 % + 2 µA 0.036 % + 2 µA 0.070 % + 20 µA 0.036 % + 20 µA 0.093 % + 200 µA 0.12 % + 200 µA HP 3458A opt-2 AC Current – Clamp-On Meter3 (10 to 25) A (25 to 150) A (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.71 % + 0.03 A 1.3 % + 0.03 A 0.73 % + 0.25 A 1.7 % + 0.25 A Fluke 5520A, Fluke 5500A/coil
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.02) 08/22/2025 Page 11 of 15 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Current – Clamp-On Meter3 (cont) (150 to 1025) A (45 to 65) Hz (65 to 440) Hz 0.71 % + 0.9 A 1.6 % + 0.9 A Fluke 5520A, Fluke 5500A/coil AC Power – Generate3 (0.01 to 0.1) W (0.1 to 890) W (0.89 to 3) kW (3 to 11) kW (11 to 20.4) kW (45 to 65) Hz; PF=1 0.000 45 % 0.036 % 0.049 % 0.26 % 0.26 % Fluke 5520A IV. Mechanical Parameter/Equipment Range CMC2, 4, 8 (±) Comments Scales & Balances3 (0.001 to 500) g Up to 2 kg Up to 5 kg Up to 10 kg Up to 20 kg (> 20 to 40) kg (0.5 to 1) lb (> 1 to 325) lb 1.0 mg + 0.6R 4.0 mg + 0.6R 6.3 mg + 0.6R 14 mg + 0.6R 26 mg + 0.6R 30 mg + 0.6R 0.02 % + 0.6R 0.01 % + 0.6R Ultra-Class weights Class F weights Force – Measuring Equipment3 Compression /Tension Up to 500 lbf 1.3 % of value + 0.0016 lbf Load cell
12-Nitrogen Gas
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.02) 08/22/2025 Page 12 of 15 Parameter/Equipment Range CMC2, 4, 8 (±) Comments Analytical Balances3 Up to 5 mg Up to 500 mg Up to 5 g Up to 50 g Up to 100 g Up to 200 g Up to 500 g Up to 1 kg Up to 2 kg Up to 5 kg Up to 10 kg 1.7 µg + 0.6R 2.0 µg + 0.6R 3.5 µg + 0.6R 7.9 µg + 0.6R 11 µg + 0.6R 0.072 mg + 0.6R 0.075 mg + 0.6R 0.087 mg + 0.6R 0.28 mg + 0.6R 0.78 mg + 0.6R 2.7 mg + 0.6R Class E1 mass set Mass – Measure 1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 200 mg 500 mg 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 kg 5 kg 10 kg 1.2 µg 1.0 µg 1.5 µg 1.8 µg 1.6 µg 1.9 µg 1.7 µg 1.5 µg 1.7 µg 2.3 µg 4.9 µg 3.7 µg 6.4 µg 6.4 µg 21 µg 24 µg 30 µg 40 µg 0.06 mg 0.81 mg 1.1 mg 1.8 mg Mettler Toledo PR10003, XPR36C, AX1005 mass comparators & class E1 mass set Pressure3 –Measuring Equipment Nitrogen Gas (-14.5 to 300) psig (> 300 to 500) psig (> 500 to 1000) psig 0.082 psig + 0.58R 0.27 psig + 0.58R 0.52 psig + 0.58R Druck PM620 Eaton UPC5000 pressure calibrator
See scope document
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.02) 08/22/2025 Page 13 of 15 Parameter/Equipment Range CMC2, 4, 8 (±) Comments Torque Wrenches3 – Measure (5 to 50) ozf·in (2.5 to 25) lbf·in (25 to 250) lbf·in (20 to 250) lbf·ft 0.67 % + 0.58R 0.96 % + 0.58R 0.61 % + 0.58R 0.61 % + 0.58R AWS torque transducers Torque – Measuring Equipment3 (1 to 50) ozf·in (1 to 100) lbf in 0.16 % 0.32 % Calibration arms & weights VI. Thermodynamics Parameter/Equipment Range CMC2, 4, 8 (±) Comments Relative Humidity – Measure3 (15 to 90) % RH (90 to 95) % RH 1.3 % RH 2.2 % RH Vaisala MI70 w/ HMP75 Relative Humidity – Measuring Equipment3 (15 to 80) % RH 1.4 % RH Vaisala MI70 w/ HMP75, humidity chamber Temperature – Measuring Equipment3 (-50 to 140) °C 0.18 °C Comparison to PRT w/ readout, thermal well Temperature – Measure3 (-196 to 420) °C 0.004 % + 0.037 °C Comparison to PRT w/ readout Infrared Thermometers3 – Measuring Equipment (25 to 100) °C (> 100 to 500) °C 0.68 °C 2.8 °C Fluke blackbody source Emissivity = 0.95 Wavelength (8 to 14) µm
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.02) 08/22/2025 Page 14 of 15 VII. Time & Frequency Parameter/Equipment Range CMC2, 4, 8 (±) Comments Frequency – Measuring Equipment3 10 MHz DC to 10 MHz 10 MHz to 26.5 GHz 0.01 Hz to 2 MHz 1.5 nHz/Hz 1.5 µHz/Hz 1.5 nHz/Hz + 0.6R 2.1 µHz + 0.001 Hz Agilent Z3805A, GPS receiver RF signal generator, GPS receiver Fluke 5520A Frequency – Measure3 DC to 12.4 GHz 1.2 nHz/Hz Counter locked to Agilent Z3805A, GPS receiver Timers/Stopwatches3 1 s to 6 hr 39 ms Counter locked to Agilent Z3805A, GPS receiver Tachometer – Optical Pickup3 (60 to 200 000) rpm 0.002 % + 0.6R Agilent 3325B ___________________________________________________________ 1 This laboratory offers commercial calibration, dimensional testing and field calibration service. 2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, R is the numerical value of the resolution of the device. In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. In the statement of CMC, adjustable thread rings are set to applicable specifications using calibrated master set plug gages. In the statement of CMC, percentages are percent of reading, unless otherwise indicated. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.02) 08/22/2025 Page 15 of 15 6 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. 7 This scope meets A2LA’s P112 Flexible Scope Policy. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
16ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

800 Pleasant Valley Drive, Springboro, OH, 45066, US

39.55228, -84.23327

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.