SIMCO Electronics - Dayton
800 Pleasant Valley Drive, 45066, Springboro, OH, United States
Visit website- Scope lines
- 16
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 16 scope lines.
A2LA certificate 1395.02 · 16 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 1 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.02) 08/22/2025 Page 2 of 15
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Surface Roughness –
Roughness Average
(Patch)
(13 to 120) µin
8.6 µin
Mitutoyo SJ-410
Surface Roughness
Tester
3 µm, 0.35 µm, & 0.4
µm
(1.2 % of value +
0.017) µm
Roughness patch
Micrometers3 –
Linearity
Flatness
Parallelism
Up to 36 in
Up to 1 in
Up to 0.001 in
(36 + 4.2L) µin
5.6 µin
5.6 µin
Gage blocks
Optical flat
Optical parallel
Height Gages3
Up to 40 in
(120 + 4.2L) µin
Gage blocks w/ surface
plate
Depth Gages3
Up to 12 in
(120 + 4.2L) µin
Gage blocks w/ surface
plate
Feeler Gages &
Thickness Specimens
Up to 1 in
(20 + 1.5L) µin
Zeiss ULM w/
Gage blocks
Calipers3
Up to 40 in
(90 + 4.2L) µin
Gage blocks / cal kit
Cylinders - Plug Gages,
Pin Gages & Master
Setting Discs
(0.01 to 4) in
(14 + 2.2L) µin
Zeiss ULM w/
Gage blocks
Surface Plates3 –
Overall Flatness
(12 to 60) in
78 µin
Planekator
Optical Flats –
Flatness
Up to 4 in Diameter
4.2 µin
Van Keuren 12 in
optical flat | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.02) 08/22/2025 Page 3 of 15
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Angle Meters &
Protractors
(0 to 90)°
0.03° + 0.6R
Gage blocks & sine bar
II. Dimensional Testing/Calibration1
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Length – 1D6
Up to 4 in
(> 4 to 12) in
(12 + 2.2L) µin
(20 + 2.5L) µin
Zeiss ULM w/ gage
blocks
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range CMC2, 5 (±) Comments
DC Voltage – Generate3
(0 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1000) V
41 µV/V + 1 µV
11 µV/V + 2 µV
11 µV/V + 20 µV
26 µV/V + 0.15 mV
16 µV/V + 1.5 mV
Fluke 5520A/SC600
DC Voltage – Measure3
(0 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
9.3 µV/V + 0.3 µV
7.9 µV/V + 0.3 µV
7.1 µV/V + 0.5 µV
9.4 µV/V + 30 µV
9.4 µV/V + 0.1 mV*
HP 3458A opt-2
*Add 12(V
in/1000)2
µV/V to all Vin > 100 | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.02) 08/22/2025 Page 4 of 15
Parameter/Equipment
Range CMC2, 4, 5 (±) Comments
DC High Voltage –
Measure3
(1 to 90) kV
0.12 % + 0.000 014 V
Ross Engineering
VD90-16.5Y-AK-KB-
AL, Fluke 87V
DC Current – Generate3
(0 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20) A
(20 to 100) A
0.013 % + 0.02 µA
0.0093 % + 0.05 µA
0.0092 % + 0.25 µA
0.0094 % + 2.5 µA
0.017 % + 40 µA
0.03 % + 40 µA
0.039 % + 500 µA
0.08 % + 750 µA
0.11 % + 10 mA
Fluke 5520A/SC600
Valhalla 2555A
DC Current – Measure3
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
24 µA/A + 5 nA
25 µA/A + 50 nA
42 µA/A + 0.50 µA
140 µA/A + 1 µA
HP 3458A opt-2
DC Current – Clamp on
Meters & Current
Transformers3
(10 to 25) A
(25 to 150) A
(150 to 1025) A
0.62 % + 0.02 A
0.62 % + 0.14 A
0.62 % + 0.5 A
Fluke 5520A/SC600,
Fluke 5500A/coil,
HP 3458A OPT-2
DC Current Shunts3
(1 to 10) mΩ,
Up to 100 A
0.032 %
HP 3458A opt-2 w/
Valhalla 2555A
DC Power – Generate
33 mV to 1020 V:
(0.33 to 329.99) mA
(0.33 to 2.9999) A
(3 to 20.5) A
(0.01 to 330) W
(0.33 to 3.3) kW
(3.3 to 20.5) kW
0.019 % + 0.000 58 W
0.013 % + 0.2 W
0.046 % + 2.9 W
Fluke 5520A/SC600
Resistance – Measure3
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(100 to 1000) MΩ
35 µΩ/Ω + 50 µΩ
22 µΩ/Ω + 0.5 mΩ
16 µΩ/Ω + 0.5 mΩ
16 µΩ/Ω + 5.0 mΩ
16 µΩ/Ω + 50 mΩ
21 µΩ/Ω + 2 Ω
83 µΩ/Ω + 100 Ω
0.06 % + 1 kΩ
0.61 % + 10 kΩ
HP 3458A opt-2 | to 90 kV |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.02) 08/22/2025 Page 5 of 15
Parameter/Equipment
Range CMC2, 5 (±) Comments
Resistance – Generate3
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(0.33 to 1.1) GΩ
0.0083 % + 1.0 mΩ
0.006 % + 1.5 mΩ
32 µΩ/Ω + 1.4 mΩ
25 µΩ/Ω + 2.0 mΩ
28 µΩ/Ω + 2.0 mΩ
26 µΩ/Ω + 0.02 Ω
26 µΩ/Ω + 0.02 Ω
26 µΩ/Ω + 0.2 Ω
26 µΩ/Ω + 0.2 Ω
36 µΩ/Ω + 2 Ω
34 µΩ/Ω + 2 Ω
0.0078 % + 30 Ω
0.014 % + 50 Ω
0.024 % + 2.5 kΩ
0.053 % + 3 kΩ
0.24 % + 0.10 MΩ
1.2 % + 0.50 MΩ
Fluke 5520A
Oscilloscopes3 –
Level Sine Amp:
50 kHz Ref
Level Sine Flatness:
5 mV to 5.5 V Relative
to 50 kHz Reference
Bandwidth
DC Signal Level
Time Marker Output
Into 50 Ω
Pulse Rise Time:
10 MHz
1 MHz
Square Wave –
Generate
50 Ω (0.01 to 10) kHz
1 MΩ (0.01 to 1) kHz
1 MΩ (1 to 10) kHz
Edge Transition Time
10 mV to 5 V(p-p)
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
Up to 130 V
Up to 6.6 V
2 ns to 20 ms
50 ms to 5 s
0.5 V, 1 V
(p-p)
1 V (p-p)
1 mV to 6.6 V(p-p)
1 mV to 130 V(p-p)
1 mV to 130 V(p-p)
(200 to 350) ps
1 kHz to 10 MHz
2.3 % + 300 µV
2.3 % + 100 µV
2.9 % + 100 µV
4.9 % + 100 µV
0.06 % + 40 µV
0.29 % + 40 µV
3 parts in 10
6
(29 + 1000t) µs/s
160 ps
160 ps
0.29 % + 40 µV
0.14 % + 40 µV
0.29 % + 40 µV
120 ps
Fluke 5520A/SC600
Into 1 MΩ load
Into 50 Ω load
Fluke 5520A/SC600
t = time in seconds | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.02) 08/22/2025 Page 6 of 15
Parameter/Equipment
Range CMC2, 5 (±) Comments
Capacitance – Generate3
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 0.7) mF
0.39 % + 10 pF
0.60 % + 10 pF
0.63 % + 10 pF
0.27 % + 10 pF
0.26 % + 0.1 nF
0.24 % + 0.1 nF
0.29 % + 0.3 nF
0.24 % + 1.0 nF
0.20 % + 3.0 nF
0.21 % + 10 nF
0.33 % + 30 nF
0.43 % + 0.1 µF
0.36 % + 0.3 µF
0.36 % + 1.0 µF
Fluke 5520A
Electrical Simulation of
Thermocouples –
Generate/Measure3
Type E
Type J
Type K
Type S
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.58 °C
0.19 °C
0.17 °C
0.19 °C
0.25 °C
0.32 °C
0.32 °C
0.18 °C
0.22 °C
0.28 °C
0.39 °C
0.22 °C
0.20 °C
0.31 °C
0.47 °C
0.55 °C
0.42 °C
0.44 °C
0.54 °C
0.74 °C
0.30 °C
0.21 °C
0.19 °C
Fluke 5520A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.02) 08/22/2025 Page 7 of 15
Parameter/Equipment
Range CMC2, 5 (±) Comments
Electrical Calibration of
RTD Indicating Devices3 –
Pt 385, 100 Ω
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.064 °C
0.063 °C
0.086 °C
0.11 °C
0.12 °C
0.15 °C
0.27 °C
Fluke 5520A
Parameter/Range
Frequency CMC2, 5 (±) Comments
Phase Angle – Generate3
3.0 V/ 0.5 V
(All at 0°)
(10 to 65) Hz
(65 to 400) Hz
400 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.21 °
0.21 °
0.30 °
0.21 °
0.28 °
0.28 °
Fluke 5520A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.02) 08/22/2025 Page 8 of 15
Parameter/Range
Frequency CMC2, 5 (±) Comments
AC Voltage – Generate3
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.087 % + 6 µV
0.052 % + 6 µV
0.042 % + 6 µV
0.11 % + 6 µV
0.29 % + 12 µV
0.67 % + 50 µV
0.024 % + 8 µV
0.012 % + 8 µV
0.014 % + 8 µV
0.029 % + 8 µV
0.063 % + 32 µV
0.16 % + 70 µV
0.024 % + 50 µV
0.013 % + 60 µV
0.016 % + 60 µV
0.024 % + 50 µV
0.056 % + 0.13 mV
0.19 % + 0.60 mV
0.024 % + 0.65 mV
0.013 % + 0.6 mV
0.019 % + 0.6 mV
0.028 % + 0.6 mV
0.071 % + 1.6 mV
0.016 % + 2 mV
0.017 % + 6 mV
0.020 % + 6 mV
0.028 % + 6 mV
0.16 % + 50 mV
0.024 % + 10 mV
0.020 % + 10 mV
0.024 % + 10 mV
Fluke 5520A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.02) 08/22/2025 Page 9 of 15
Parameter/Range
Frequency CMC2, 5 (±) Comments
AC Voltage – Measure3
(1 to 10) mV
(10 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 700) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.07 % + 3.0 µV
0.06 % + 1.1 µV
0.06 % + 1.1 µV
0.14 % + 1.1 µV
0.58 % + 1.1 µV
4.6 % + 2.0 µV
0.02 % + 4.0 µV
0.01 % + 2.0 µV
0.018 % + 2.0 µV
0.038 % + 2.0 µV
0.094 % + 2.0 µV
0.35 % + 10 µV
1.2 % + 10 µV
0.0084 % + 40 µV
0.0085 % + 20 µV
0.017 % + 20 µV
0.036 % + 20 µV
0.093 % + 20 µV
0.35 % + 0.10 mV
1.2 % + 0.10 mV
0.013 % + 0.40 mV
0.0084 % + 0.20 mV
0.017 % + 0.20 mV
0.035 % + 0.20 mV
0.093 % + 0.20 mV
0.36 % + 1.0 mV
1.2 % + 1.0 mV
0.024 % + 4.0 mV
0.024 % + 2.0 mV
0.024 % + 2.0 mV
0.041 % + 2.0 mV
0.14 % + 2.0 mV
0.47 % + 10 mV
0.05 % + 40 mV
0.05 % + 20 mV
0.07 % + 20 mV
0.14 % + 20 mV
0.35 % + 20 mV
HP 3458A opt-2
AC High Voltage3 –
Measure @ 60 Hz
(1 to 60) kV
0.0058 V/V + 0.000 043 V
Ross Engineering
VD90-16.5Y-AK-
KB-AL, Fluke 87V | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.02) 08/22/2025 Page 10 of 15
Parameter/Range
Frequency CMC2, 5 (±) Comments
AC Current – Generate3
(29 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3.0) A
(3.0 to 11.0) A
(11.0 to 20.5) A
(20 to 100) A
(45 to 1000) Hz
(45 to 1000) Hz
(> 1 to 5) kHz
(45 to 1000) Hz
(> 1 to 5) kHz
(45 to 1000) Hz
(> 1 to 5) kHz
(45 to 1000) Hz
(> 1 to 5) kHz
(45 to 1000) Hz
(> 1 to 5) kHz
(45 to 1000) Hz
(> 1 to 5) kHz
(45 to 1000) Hz
(> 1 to 5) kHz
(45 to 1000) Hz
0.13 % + 0.10 µA
0.042 % + 0.15 µA
0.16 % + 0.20 µA
0.042 % + 2 µA
0.068 % + 2 µA
0.053 % + 20 µA
0.089 % + 50 µA
0.041 % + 0.1 mA
0.47 % + 1.0 mA*
0.079 % + 0.1 mA
0.47 % + 1.0 mA*
0.095 % + 2.0 mA
2.3 % + 2.0 mA
0.13 % + 5.0 mA
2.4 % + 5.0 mA
0.79 % + 0.082 A
Fluke 5520A/SC600
*For compliance
voltages >1V, add
1mA/V to floor
specification
Valhalla 2555A
AC Current – Measure3
(5 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(45 to 1000) Hz
(45 to 1000) Hz
(0.1 to 5) kHz
(45 to 1000) Hz
(0.1 to 5) kHz
(45 to 1000) Hz
(0.1 to 5) kHz
(45 to 1000) Hz
(0.1 to 5) kHz
0.073 % + 30 nA
0.071 % + 200 nA
0.036 % + 200 nA
0.070 % + 2 µA
0.036 % + 2 µA
0.070 % + 20 µA
0.036 % + 20 µA
0.093 % + 200 µA
0.12 % + 200 µA
HP 3458A opt-2
AC Current –
Clamp-On Meter3
(10 to 25) A
(25 to 150) A
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.71 % + 0.03 A
1.3 % + 0.03 A
0.73 % + 0.25 A
1.7 % + 0.25 A
Fluke 5520A, Fluke
5500A/coil | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.02) 08/22/2025 Page 11 of 15
Parameter/Range
Frequency CMC2, 4, 5 (±) Comments
AC Current –
Clamp-On Meter3 (cont)
(150 to 1025) A
(45 to 65) Hz
(65 to 440) Hz
0.71 % + 0.9 A
1.6 % + 0.9 A
Fluke 5520A, Fluke
5500A/coil
AC Power – Generate3
(0.01 to 0.1) W
(0.1 to 890) W
(0.89 to 3) kW
(3 to 11) kW
(11 to 20.4) kW
(45 to 65) Hz; PF=1
0.000 45 %
0.036 %
0.049 %
0.26 %
0.26 %
Fluke 5520A
IV. Mechanical
Parameter/Equipment
Range
CMC2, 4, 8 (±)
Comments
Scales & Balances3
(0.001 to 500) g
Up to 2 kg
Up to 5 kg
Up to 10 kg
Up to 20 kg
(> 20 to 40) kg
(0.5 to 1) lb
(> 1 to 325) lb
1.0 mg + 0.6R
4.0 mg + 0.6R
6.3 mg + 0.6R
14 mg + 0.6R
26 mg + 0.6R
30 mg + 0.6R
0.02 % + 0.6R
0.01 % + 0.6R
Ultra-Class weights
Class F weights
Force – Measuring
Equipment3
Compression /Tension
Up to 500 lbf
1.3 % of value +
0.0016 lbf
Load cell | ||
| 12 | - | Nitrogen GasShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.02) 08/22/2025 Page 12 of 15
Parameter/Equipment
Range
CMC2, 4, 8 (±)
Comments
Analytical Balances3
Up to 5 mg
Up to 500 mg
Up to 5 g
Up to 50 g
Up to 100 g
Up to 200 g
Up to 500 g
Up to 1 kg
Up to 2 kg
Up to 5 kg
Up to 10 kg
1.7 µg + 0.6R
2.0 µg + 0.6R
3.5 µg + 0.6R
7.9 µg + 0.6R
11 µg + 0.6R
0.072 mg + 0.6R
0.075 mg + 0.6R
0.087 mg + 0.6R
0.28 mg + 0.6R
0.78 mg + 0.6R
2.7 mg + 0.6R
Class E1 mass set
Mass – Measure
1 mg
2 mg
5 mg
10 mg
20 mg
50 mg
100 mg
200 mg
500 mg
1 g
2 g
5 g
10 g
20 g
50 g
100 g
200 g
500 g
1 kg
2 kg
5 kg
10 kg
1.2 µg
1.0 µg
1.5 µg
1.8 µg
1.6 µg
1.9 µg
1.7 µg
1.5 µg
1.7 µg
2.3 µg
4.9 µg
3.7 µg
6.4 µg
6.4 µg
21 µg
24 µg
30 µg
40 µg
0.06 mg
0.81 mg
1.1 mg
1.8 mg
Mettler Toledo
PR10003, XPR36C,
AX1005 mass
comparators & class E1
mass set
Pressure3 –Measuring
Equipment
Nitrogen Gas
(-14.5 to 300) psig
(> 300 to 500) psig
(> 500 to 1000) psig
0.082 psig + 0.58R
0.27 psig + 0.58R
0.52 psig + 0.58R
Druck PM620
Eaton UPC5000
pressure calibrator | See scope document |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.02) 08/22/2025 Page 13 of 15
Parameter/Equipment
Range
CMC2, 4, 8 (±)
Comments
Torque Wrenches3 –
Measure
(5 to 50) ozf·in
(2.5 to 25) lbf·in
(25 to 250) lbf·in
(20 to 250) lbf·ft
0.67 % + 0.58R
0.96 % + 0.58R
0.61 % + 0.58R
0.61 % + 0.58R
AWS torque
transducers
Torque – Measuring
Equipment3
(1 to 50) ozf·in
(1 to 100) lbf in
0.16 %
0.32 %
Calibration arms &
weights
VI. Thermodynamics
Parameter/Equipment
Range
CMC2, 4, 8 (±)
Comments
Relative Humidity –
Measure3
(15 to 90) % RH
(90 to 95) % RH
1.3 % RH
2.2 % RH
Vaisala MI70 w/
HMP75
Relative Humidity –
Measuring Equipment3
(15 to 80) % RH
1.4 % RH
Vaisala MI70 w/
HMP75, humidity
chamber
Temperature – Measuring
Equipment3
(-50 to 140) °C
0.18 °C
Comparison to PRT
w/ readout, thermal
well
Temperature – Measure3
(-196 to 420) °C
0.004 % + 0.037 °C
Comparison to PRT
w/ readout
Infrared Thermometers3
– Measuring Equipment
(25 to 100) °C
(> 100 to 500) °C
0.68 °C
2.8 °C
Fluke blackbody
source
Emissivity = 0.95
Wavelength (8 to 14)
µm | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.02) 08/22/2025 Page 14 of 15
VII. Time & Frequency
Parameter/Equipment
Range
CMC2, 4, 8 (±)
Comments
Frequency – Measuring
Equipment3
10 MHz
DC to 10 MHz
10 MHz to 26.5 GHz
0.01 Hz to 2 MHz
1.5 nHz/Hz
1.5 µHz/Hz
1.5 nHz/Hz + 0.6R
2.1 µHz + 0.001 Hz
Agilent Z3805A, GPS
receiver
RF signal generator, GPS
receiver
Fluke 5520A
Frequency – Measure3
DC to 12.4 GHz
1.2 nHz/Hz
Counter locked to Agilent
Z3805A, GPS receiver
Timers/Stopwatches3
1 s to 6 hr
39 ms
Counter locked to Agilent
Z3805A, GPS receiver
Tachometer – Optical
Pickup3
(60 to 200 000) rpm
0.002 % + 0.6R
Agilent 3325B
___________________________________________________________
1 This laboratory offers commercial calibration, dimensional testing and field calibration service.
2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a
laboratory can achieve within its scope of accreditation when performing more or less routine calibrations
of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded
uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of
k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be
greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, R is the numerical value of the resolution of the device. In the statement of
CMC, L is the numerical value of the nominal length of the device measured in inches. In the statement
of CMC, adjustable thread rings are set to applicable specifications using calibrated master set plug gages.
In the statement of CMC, percentages are percent of reading, unless otherwise indicated.
5 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification. | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.02) 08/22/2025 Page 15 of 15
6 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration.
7 This scope meets A2LA’s P112 Flexible Scope Policy.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 16 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Western Environmental a Division of Controlled Environment Systems (CES)Springboro, OH · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- American Testing Services,Miamisburg, OH · ~6 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Mitutoyo America CorporationWest Chester, OH · ~29 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Instrument Calibration SolutionsClayton, OH · ~36 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Midwest MetrologyClayton, OH · ~36 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.