UL Japan, Inc. Automotive Technology Center
1-3-19 Neuramachi, Miyoshi-shi, Aichi, 470-0217, Japan, Miyoshi-shi, Aichi, Japan
Visit website- Accredited standards
- 26
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 26 standard numbers and the 25 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series10
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-21
ISO 11452 series8
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-3Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 3: Transverse electromagnetic (TEM) cell
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methodsExclusion
Limits written next to it
ISO 11452-4 (excluding Sections 6.2, 7.6.2, 8.6.2
ISO 11452-5Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 5: Stripline
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
ISO 11452-10Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 10: Immunity to conducted disturbances in the extended audio frequency range
ISO 11452-11Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 11: Reverberation chamberExclusion
Limits written next to it
Reverberation Chamber ISO 11452-11 (80 MHz to 18 GHz, except 6-7.5GHz)
ISO 7637 series3
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 7637-4Road Vehicles - Electrical disturbance by conduction and coupling - Part 4: Electrical transient conduction along shielded high voltage supply lines only
Other standards5
CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receiversSome clauses
Limits written next to it
EN 55025 (clause 6.5)
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
EN 50498Electromagnetic compatibility (EMC) - Product family standard for aftermarket electronic equipment in vehicles
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 11452-10; ISO 11452-11; ISO 7637-2; ISO 7637-3; ISO 7637-4; UN ECE Regulation 10; ISO 16750-2; SAE J1113-25; ANSI C63.4; CISPR 16-2-1; IEC 61000-3-2; IEC 61000-3-12; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-2; EN 61000-4-2; IEC 61000-4-3; EN 61000-4-3; EN IEC 61000-4-3; IEC 61000-4-21; RTCA DO-160G; IEC 61000-4-6; EN 61000-4-6
ISO 10605; CISPR 25; EN 55025; UN ECE Regulation 10; ISO 11452-2; ISO 11452-3; ISO 11452-4; ISO 11452-5; ISO 11452-8; ISO 11452-9
CISPR 35; EN 55035; EN 50498
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active5107.03
The scope document we hold says it is valid until 2027-11-30.
Accredited scope, certificate 5107.03
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 10605; CISPR 25; EN 55025; UN ECE Regulation 10; ISO 11452-2; ISO 11452-3; ISO 11452-4; ISO 11452-5; ISO 11452-8; ISO 11452-9 | - | See scope document |
| 2 | ISO 11452-10; ISO 11452-11; ISO 7637-2; ISO 7637-3; ISO 7637-4; UN ECE Regulation 10; ISO 16750-2; SAE J1113-25; ANSI C63.4; CISPR 16-2-1; IEC 61000-3-2; IEC 61000-3-12; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-2; EN 61000-4-2; IEC 61000-4-3; EN 61000-4-3; EN IEC 61000-4-3; IEC 61000-4-21; RTCA DO-160G; IEC 61000-4-6; EN 61000-4-6 | - | See scope document |
| 3 | CISPR 35; EN 55035; EN 50498 | - | - |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
UL JAPAN, INC. AUTOMOTIVE TECHNOLOGY CENTER
Miyoshi-shi, Aichi, Japan
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 29th day of October 2025.
______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 5107.03
Valid to November 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
1-3-19 Neuramachi, Miyoshi-shi, Aichi, 470-0217, Japan, Miyoshi-shi, Aichi, JP
35.09933, 137.09953
Open in MapsLabs with overlapping accredited scope in Japan
- LAB SupportAzumino-shi, Nagano-ken · ~152 kmA2LAShares 2 accredited test methodsISO 10605ISO 7637-2
- OKI ENGINEERING CO.,Honjo-shi, Saitama-ken · ~228 kmA2LAShares 2 accredited test methodsISO 10605ISO 7637-2
- TOYO Corporation Calibration LaboratoryTokyo 135-0042 · ~248 kmA2LAShares 2 accredited test methodsISO 10605ISO 7637-2
- UL Japan, Inc. - Kashima EMCChiba-ken, 289-0341 · ~274 kmA2LAShares 2 accredited test methodsISO 10605ISO 7637-2
- Denken Co., Ltd. EMC Test Lab.Kariya-shi, Aichi-ken, · ~16 kmA2LAShares 1 accredited test methodISO 10605
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.