SIMCO Electronics - Seattle
14613 NE 87th Street, 98052, Redmond, WA, United States
Visit website- Scope lines
- 22
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 22 scope lines.
A2LA certificate 1395.12 · 22 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 16 in |
| 2 | ASME/ANSI B1.2-1983; ASME/ANSI B1.3-2007 | - | to 12 in |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 3 of 21
III. Electrical – DC / Low Frequency
Parameter/Equipment
Range CMC2, 4, 5, 6 (±) Comments
DC Voltage – Generate3
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
9.0 µV/V + 1.3 µV
7.1 µV/V + 1.6 µV
7.1 µV/V + 4.2 µV
7.1 µV/V + 7.6 µV
8.1 µV/V + 84 µV
9.3 µV/V + 0.52 mV
Fluke 5700A
DC Voltage – Measure3
(0 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100 V
(100 to 1000) V*
6.9 µV/V + 0.45 µV
5.4 µV/V + 0.47 µV
5.4 µV/V + 0.95 µV
8.0 µV/V + 44 µV
8.0 µV/V + 0.26 mV*
HP 3458A opt-2
*add 12 µV/V
(V
in/1000)2 to all Vin >
100
DC Current – Generate3
(0 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(11 to 20.5) A
(0 to 10) A
50 µA/A + 8 nA
51 µA/A + 8 nA
50 µA/A + 80 nA
79 µA/A + 0.8 µA
83 µA/A + 25 µA
0.036 % + 480 µA
0.079 % + 0.59 mA
4 µA/A + 1.6 mA
Fluke 5700A/5725A
Fluke 5520A/SC1100
HP 3458A w/ Guildline
9230-300
DC Current – Clamp-On
Meters3
(20 to 150) A
(150 to 1000) A
0.58 % + 160 mA
0.58 % + 720 mA
Fluke 5520A/SC1100
Fluke 5500A/coil
DC High Voltage –
Generate
(1 to 25) kV
0.067 % + 1.1 mV
Hipotronics HD100
monitored with HP
34401A & Ross
Engineering VD60-6.2
DC High Voltage –
Measure3
(1 to 60) kV
0.067 % + 1.1 mV
HP 34401A & Ross
Engineering VD60-6.2 | to 220 V |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 4 of 21
Parameter/Equipment
Range
CMC2, 4, 5, 6 (±)
Comments
DC Current – Measure3
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(> 1 to 10) A
(> 10 to 120) A
27 µA/A + 7.5 nA
29 µA/A + 75 nA
44 µA/A + 0.75 µA
0.013 % + 16 µA
12 µA/A + 6.6 µA
4.8 µA/A + 3.3 mA
HP 3458A opt-2
HP 3458A opt-2 w/
Guildline 9230-300
Resistance – Generate3
1 mΩ
10 mΩ
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(0.11 to 0.33) GΩ
(0.33 to 1.1) GΩ
0.14 µΩ
2.2 µΩ
4.9 µΩ
0.12 mΩ
0.16 mΩ
1.1 mΩ
12 mΩ
94 mΩ
3.3 Ω
21 Ω
32 µΩ/Ω + 0.78 mΩ
24 µΩ/Ω + 1.2 mΩ
22 µΩ/Ω + 1.1 mΩ
22 µΩ/Ω + 1.6 mΩ
22 µΩ/Ω + 1.6 mΩ
22 µΩ/Ω + 16 mΩ
22 µΩ/Ω + 16 mΩ
22 µΩ/Ω + 0.16 Ω
22 µΩ/Ω + 0.16 Ω
28 µΩ/Ω + 1.6 Ω
28 µΩ/Ω + 1.6 Ω
52 µΩ/Ω + 24 Ω
0.011 % + 40 Ω
0.021 % + 2.0 kΩ
0.041 % + 2.7 kΩ
0.24 % + 80 kΩ
1.2 % + 0.39 MΩ
Standard resistors
Fluke 5520A/SC1100
CMCs shown are based
on 4-wire compensation
only; for 2-wire & 2-
wire compensation add
5 µV per ampere
stimulus current
(R
floor = E/I) | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 5 of 21
Parameter/Equipment
Range
CMC2, 4, 6, 7 (±)
Comments
Resistance – Measure3
Up to 10 Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
19 µΩ/Ω + 85 µΩ
16 µΩ/Ω + 0.82 mΩ
14 µΩ/Ω + 0.82 mΩ
14 µΩ/Ω + 8.2 mΩ
14 µΩ/Ω + 83 mΩ
20 µΩ/Ω + 2.7 Ω
62 µΩ/Ω + 0.12 kΩ
0.059 % + 3.7 kΩ
0.58 % + 0.26 MΩ
HP 3458A opt-2
Oscilloscopes3 –
Level Sine Amp:
50 kHz to 10 MHz Ref
Level Sine Flatness:
4.44 mV to 5.56 V
Relative to 50 kHz to
10 MHz Reference
Square Wave:
10 Hz to 10 kHz
50 Ω Impedance
(Peak to Peak)
1 MΩ Impedance
(Peak to Peak)
Time Marker Output
Edge Transition:
4.44 mV
(p-p) to 3.1 V(p-p)
10 Hz to 2 MHz Rate
4.4 mV to 5.6 V
(p-p)
100 mHz to 100 MHz
(100 to 550) MHz
(550 to 1100) MHz
(35.52 to 999.90) µV
(1.0 to 21.0) mV
(21.001 to 556.0) mV
556.01 mV to 5.56 V
(35.52 to 999.90) µV
(1.0 to 21.0) mV
(21.001 to 556.0) mV
556.01 mV to 210.0 V
450.50 ps to < 1 ms
1 ms to 55.00 s
150 ps
500 ps
1.7 %
2.2 %
4 %
4.8 %
1.2 % + 12 µV
0.13 % + 17 µV
0.13 % + 1.2 µV
0.075 % + 1.2 µV
1.2 % + 12 µV
0.12 % + 17 µV
0.12 % + 1.2 µV
0.058 % + 1.2 µV
0.29 µs/s
0.36 µs/s
12 ps
28 ps
Fluke/Wavetek 9500
scope calibrator w/
9530 active head | to 10 Ω |
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 6 of 21
Parameter/Range
Frequency CMC2, 4, 5 (±) Comments
Phase Angle – Generate3
(0 to 360)°
(10 to 65) Hz
(65 to 500) Hz
(0.5 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
0.14°
0.30°
0.59°
2.9°
5.8°
Fluke 5520A/SC1100
Parameter/Equipment
Range CMC2, 4, 5 (±) Comments
Electrical Simulation of
Thermocouple –
Generate3
Type K
Type E
Type J
Type K
Type T
(-270 to 1373) °C
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.084 °C
0.39 °C
0.13 °C
0.11 °C
0.13 °C
0.16 °C
0.21 °C
0.13 °C
0.11 °C
0.13 °C
0.18 °C
0.26 °C
0.14 °C
0.13 °C
0.20 °C
0.31 °C
0.49 °C
0.19 °C
0.13 °C
0.11 °C
Fluke 5700A mV(dc)
output with external
thermocouple reference
probe & ice point
reference
Fluke 5520A/SC1100 | 0 to 360 ° |
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 7 of 21
Parameter/Equipment
Range CMC2, 5 (±) Comments
Electrical Simulation of
Thermocouple –
Measure3
Type K
Type E
Type J
Type K
Type T
(-270 to 1373) °C
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 600) °C
(600 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.084 °C
0.39 °C
0.13 °C
0.11 °C
0.13 °C
0.16 °C
0.21 °C
0.13 °C
0.11 °C
0.13 °C
0.18 °C
0.26 °C
0.14 °C
0.13 °C
0.20 °C
0.31 °C
0.49 °C
0.19 °C
0.13 °C
0.11 °C
Keysight 3458A
DMM w/ external
thermocouple
reference probe & ice
point reference
Fluke 5522A/SC1100 | -270 to 1373 °C |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 8 of 21
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Voltage – Generate3
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(45 to 1000) Hz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.064 % + 6 µV
0.019 % + 6 µV
0.022 % + 6 µV
0.082 % + 6 µV
0.28 % + 12 µV
0.63 % + 50 µV
0.034 % + 8 µV
0.012 % + 8 µV
0.014 % + 8 µV
0.028 % + 8 µV
0.064 % + 32 µV
0.16 % + 70 µV
0.024 % + 50 µV
0.012 % + 60 µV
0.016 % + 60 µV
0.024 % + 50 µV
0.056 % + 130 µV
0.19 % + 600 µV
0.024 % + 0.6 mV
0.012 % + 0.6 mV
0.020 % + 0.6 mV
0.028 % + 0.6 mV
0.070 % + 1.6 mV
0.016 % + 2 mV
0.016 % + 6 mV
0.020 % + 6 mV
0.028 % + 6 mV
0.16 % + 50 mV
0.024 % + 12 mV
0.020 % + 12 mV
0.024 % + 12 mV
Fluke 5520A/SC1100;
LCOMP off | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 9 of 21
Parameter/Range
Frequency CMC2, 4, 6 (±)
Comments
AC Voltage – Measure3
(1 to 10) mV
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 700) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.035 % + 3.5 µV
0.023 % + 1.3 µV
0.035 % + 1.3 µV
0.12 % + 1.3 µV
0.58 % + 1.3 µV
4.6 % + 2.4 µV
89 µV/V + 4.7 µV
89 µV/V + 2.5 µV
0.017 % + 2.6 µV
0.035 % + 2.3 µV
0.093 % + 2.4 µV
0.35 % + 12 µV
1.2 % + 12 µV
89 µV/V + 47 µV
89 µV/V + 25 µV
0.017 % + 24 µV
0.035 % + 24 µV
0.093 % + 24 µV
0.35 % + 0.12 mV
1.2 % + 0.12 mV
89 µV/V + 0.48 mV
89 µV/V + 0.26 mV
0.017 % + 0.31 mV
0.035 % + 0.26 mV
0.093 % + 0.25 mV
0.35 % + 1.2 mV
1.2 % + 1.2 mV
0.023 % + 4.7 mV
0.023 % + 2.5 mV
0.023 % + 2.5 mV
0.041 % + 2.3 mV
0.14 % + 2.4 mV
0.046 % + 47 mV
0.046 % + 24 mV
0.069 % + 23 mV
0.14 % + 23 mV
0.35 % + 23 mV
HP 3458A opt-2 | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 10 of 21
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Current – Generate3
(22 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 3) A
(3 to 11) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 40) Hz
(40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(20 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.070 % + 16 nA
0.036 % + 20 nA
0.013 % + 8 nA
0.062 % + 40 nA
0.16 % + 80 nA
0.075 % + 41 nA
0.037 % + 35 nA
0.016 % + 35 nA
0.060 % + 0.4 µA
0.16 % + 0.8 µA
0.075 % + 0.41 µA
0.036 % + 0.35 µA
0.013 % + 0.35 µA
0.060 % + 4.0 µA
0.16 % + 8.0 µA
0.075 % + 4.1 µA
0.037 % + 3.5 µA
0.015 % + 3.5 µA
0.060 % + 60 µA
0.16 % + 80 µA
0.066 % + 35 µA
0.045 % + 80 µA
0.70 % + 160 µA
0.047 % + 0.084 mA
0.47 % + 0.78 mA
0.047 % + 1.6 mA
0.081 % + 1.6 mA
2.3 % + 1.6 mA
0.096 % + 1.6 mA
0.096 % + 3.9 mA
2.3 % + 3.9 mA
Fluke 5700A
Fluke
5520A/SC1100 | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 11 of 21
Parameter/Range
Frequency
CMC2, 4, 5, 6 (±)
Comments
AC Current – Measure3
(5 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
5 mA to 1.3 A
(1.25 to 6.5) A
(5 to 13) A
(10 to 26) A
(> 1 to 20) A
45 Hz to 1 kHz
(45 to 100) Hz
100 Hz to 5 kHz
(45 to 100) Hz
100 Hz to 5 kHz
(45 to 100) Hz
100 Hz to 5 kHz
(45 to 100) Hz
100 Hz to 5 kHz
40 Hz to 10 kHz
40 Hz to 10 kHz
40 Hz to 10 kHz
40 Hz to 5 kHz
(40 to 1000) Hz
0.072 % + 0.035 µA
0.070 % + 0.23 µA
0.036 % + 0.23 µA
0.070 % + 2.3 µA
0.035 % + 2.3 µA
0.070 % + 23 µA
0.036 % + 23 µA
0.093 % + 0.23 mA
0.12 % + 0.23 mA
0.036 %
0.058 %
0.054 %
0.11 %
0.042 % + 3.6 mA
HP 3458A opt-2
Holt HCS-1 current
shunts, Keysight
3458A opt 2
Keysight 3458A opt-2
w/ Fluke Y5020
AC Current – Clamp-on
Meter3
(20 to 150) A
(150 to 1000) A
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.56 % + 290 mA
1.0 % + 290 mA
0.57 % + 1 A
1.0 % + 1 A
Fluke 5520A/SC1100
Fluke 5500A/coil
AC High Voltage –
Generate3
(1 to 20) kV,
@ 60 Hz
0.25 % + 3.7 mV
Hipotronics HD100
monitored w/ HP
34401A & Ross
Engineering
VD60-6.2
AC High Voltage –
Measure3
(1 to 40) kV,
@ 60 Hz
0.25 % + 3.7 mV
HP34401A & Ross
Engineering VD60-
6.2 | ||
| 12 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 12 of 21
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
Capacitance3 – Generate
1 pF to 1 µF
(0.19 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.9999) mF
0.12 % + 0.58R
0.39 % + 0.0085 nF
0.19 % + 0.011 nF
0.19 % + 0.1 nF
0.19 % + 0.32 nF
0.19 % + 1 nF
0.19 % + 2.9 nF
0.19 % + 12 nF
0.31 % + 33 nF
0.35 % + 150 nF
0.35 % + 420 nF
0.35 % + 1.1 µF
0.35 % + 2.6 µF
0.35 % + 9.7 µF
HP 4236B & various
fixed capacitors
Fluke 5520A/SC1100
Capacitance3 – Measure,
12 Hz to 100 kHz8
(0.01 to 10) pF
(10 to 100) pF
100 pF to 25 µF
(25 to 100) µF
(100 to 1000) µF
0.47 %
0.075 %
0.035 %
0.063 %
0.063 %
GenRad 1689
Inductance – Generate
100 µH
500 µH
1 mH
10 mH
100 mH
1 H
10 H
0.13 µH
0.90 µH
1.3 µH
4.9 µH
31 µH
270 µH
7.2 mH
Various fixed
inductors
Inductance – Measure3
100 µH to 100 mH
> 100 mH to 1 H
(> 1 to 10) H
0.062 %
0.066 %
0.23 %
GenRad 1689 | 1 to 10 H |
| 13 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 13 of 21
IV. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
RF Power – Generate3
(-20 to +20) dBm
(-20 to +20) dBm
100 kHz to 50 MHz
50 MHz to 2 GHz
(> 2 to 12) GHz
(> 12 to 18) GHz
100 kHz to 1.3 GHz
(1.3 to 3) GHz
(3 to 26.5) GHz
0.17 dB
0.17 dB
0.26 dB
0.27 dB
0.16 dB
0.17 dB
0.42 dB
E4418B power meter w/
8482A sensor &
HP11667A, HP 3325B
E4418B power meter w/
8481A sensor &
HP11667A, HP 83630B
Agilent/HP 8902A w/
11722A & 11667A,
Agilent 8648D
Agilent/HP 8902A w/
11722A & 11667B, HP
83630B
Absolute RF Power –
Measure3
(-20 to +20) dBm
0 dBm
(-20 to +20) dBm
150 kHz to 2.6 GHz
50 MHz to 3 GHz
(3 to 26.5) GHz
50 MHz
100 kHz to 50 MHz
> 50 MHz to 2 GHz
(> 2 to 12.4) GHz
(> 12.4 to 18) GHz
0.066 dB
0.088 dB
0.13 dB
1.3 % (0.056 dB)
1.8 %
1.6 %
1.8 %
1.9 %
Agilent/HP 8902A w/
11722A
Agilent/HP 8902A w/
8485A
HP 432A power meter
& thermistor w/ DC
substitution
E4418B power meter w/
8482A sensor
E4418B power meter w/
8481A sensor | -20 to 20 dBm |
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 14 of 21
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
RF Attenuation –
Generate3
2.5 MHz to 1.3 GHz
(> 1.3 to 12.4) GHz
(> 12.4 to 18) GHz
(0 to < 10) dB
(10 to < 20) dB
(20 to < 30) dB
(30 to < 40) dB
(40 to < 50) dB
(50 to < 60) dB
(60 to < 70) dB
(70 to < 80) dB
(80 to < 90) dB
(90 to < 100) dB
(100 to < 110) dB
(110 to < 120) dB
(120 to 127) dB
(0 to < 10) dB
(10 to < 20) dB
(20 to < 30) dB
(30 to < 40) dB
(40 to < 50) dB
(50 to < 60) dB
(60 to < 70) dB
(70 to < 80) dB
(80 to < 90) dB
(90 to < 99) dB
(99 to < 100) dB
(100 to < 110) dB
(110 to < 120) dB
(120 to 127) dB
(0 to < 10) dB
(10 to < 20) dB
(20 to < 30) dB
(30 to < 40) dB
(40 to < 50) dB
(50 to < 60) dB
(60 to < 70) dB
(70 to < 80) dB
(80 to < 90) dB
(90 to < 94) dB
(94 to < 100) dB
(100 to < 110) dB
(110 to < 120) dB
(120 to 127) dB
0.020 dB
0.026 dB
0.036 dB
0.046 dB
0.056 dB
0.066 dB
0.076 dB
0.086 dB
0.096 dB
0.11 dB
0.52 dB
0.58 dB
0.80 dB
0.020 dB
0.026 dB
0.036 dB
0.046 dB
0.056 dB
0.066 dB
0.076 dB
0.086 dB
0.096 dB
0.11 dB
0.29 dB
0.70 dB
0.75 dB
0.80 dB
0.016 dB
0.026 dB
0.036 dB
0.046 dB
0.056 dB
0.066 dB
0.076 dB
0.086 dB
0.096 dB
0.11 dB
0.29 dB
0.70 dB
0.75 dB
0.80 dB
Agilent/HP 3335A level
generator (2.5 to
80MHz), 83630B
sweeper (> 80 MHz to
26.5 GHz), 11667A
splitter, Agilent/HP
8902A measuring
receiver (option 050
verified), & 11793A
microwave converter (>
1.3 GHz) | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 15 of 21
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
RF Attenuation –
Generate3 (cont)
(> 18 to 26.5) GHz
(0 to < 10) dB
(10 to < 20) dB
(20 to < 30) dB
(30 to < 40) dB
(40 to < 50) dB
(50 to < 60) dB
(60 to < 70) dB
(70 to < 80) dB
(80 to < 89) dB
(89 to < 90) dB
(90 to < 100) dB
(100 to < 110) dB
(110 to < 120) dB
(120 to 127) dB
0.016 dB
0.026 dB
0.036 dB
0.046 dB
0.056 dB
0.066 dB
0.076 dB
0.086 dB
0.096 dB
0.28 dB
0.29 dB
0.70 dB
0.75 dB
0.80 dB
Agilent/HP 3335A level
generator (2.5 to
80MHz), 83630B
sweeper (> 80 MHz to
26.5 GHz), 11667A
splitter, Agilent/HP
8902A measuring
receiver (option 050
verified), & 11793A
microwave converter (>
1.3 GHz)
RF Attenuation –
Measure
3
2.5 MHz to 1.3 GHz
(> 1.3 to 12.4) GHz
(0 to < 10) dB
(10 to < 20) dB
(20 to < 30) dB
(30 to < 40) dB
(40 to < 50) dB
(50 to < 60) dB
(60 to < 70) dB
(70 to < 80) dB
(80 to < 90) dB
(90 to < 100) dB
(100 to < 110) dB
(110 to < 120) dB
(120 to 127) dB
(0 to < 10) dB
(10 to < 20) dB
(20 to < 30) dB
(30 to < 40) dB
(40 to < 50) dB
0.016 dB
0.026 dB
0.036 dB
0.046 dB
0.056 dB
0.066 dB
0.076 dB
0.086 dB
0.096 dB
0.11 dB
0.52 dB
0.58 dB
0.80 dB
0.020 dB
0.026 dB
0.036 dB
0.046 dB
0.056 dB
Agilent/HP 8902A
measuring receiver
(option 050 verified), &
11793A microwave
converter (> 1.3 GHz) | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 16 of 21
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
RF Attenuation – Measure3
(cont)
(> 1.3 to 12.4) GHz
(> 12.4 to 18) GHz
(> 18 to 26.5) GHz
(50 to < 60) dB
(60 to < 70) dB
(70 to < 80) dB
(80 to < 90) dB
(90 to < 99) dB
(99 to < 100) dB
(100 to < 110) dB
(110 to < 120) dB
(120 to 127) dB
(0 to < 10) dB
(10 to < 20) dB
(20 to < 30) dB
(30 to < 40) dB
(40 to < 50) dB
(50 to < 60) dB
(60 to < 70) dB
(70 to < 80) dB
(80 to < 90) dB
(90 to < 94) dB
(94 to < 100) dB
(100 to < 110) dB
(110 to < 120) dB
(120 to 127) dB
(0 to < 10) dB
(10 to < 20) dB
(20 to < 30) dB
(30 to < 40) dB
(40 to < 50) dB
(50 to < 60) dB
(60 to < 70) dB
(70 to < 80) dB
(80 to < 89) dB
(89 to < 90) dB
(90 to < 100) dB
(100 to < 110) dB
(110 to < 120) dB
(120 to 127) dB
0.066 dB
0.076 dB
0.086 dB
0.096 dB
0.11 dB
0.29 dB
0.70 dB
0.75 dB
0.80 dB
0.016 dB
0.026 dB
0.036 dB
0.046 dB
0.056 dB
0.066 dB
0.076 dB
0.086 dB
0.096 dB
0.11 dB
0.29 dB
0.70 dB
0.75 dB
0.80 dB
0.016 dB
0.026 dB
0.036 dB
0.046 dB
0.056 dB
0.066 dB
0.076 dB
0.086 dB
0.096 dB
0.28 dB
0.29 dB
0.70 dB
0.75 dB
0.80 dB
Agilent/HP 8902A
measuring receiver
(option 050 verified),
& 11793A microwave
converter (> 1.3 GHz) | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 17 of 21
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
Amplitude Modulation –
Measure3
Rate: 50 Hz to 10 kHz
Depths: (5 to 99) %
Rate: 20 Hz to 10 kHz
Depths: Up to 99 %
Rate: 50 Hz to 50 kHz
Depths: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depths: Up to 99 %
Rate: 50 Hz to 50 kHz
Depths: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depths: Up to 99 %
150 kHz to 10 MHz
> 10 MHz to 1.3GHz
(> 1.3 to 26.5) GHz
2.1 % + 1 digit
3.0 % + 1 digit
1.1 % + 1 digit
3.0 % + 1 digit
1.6 % + 1 digit
3.0 % + 1 digit
Agilent/HP 8902A
measuring receiver
w/ 11722A sensor
Amplitude Modulation –
Generate
3
50 Hz to 50 kHz < 95 %
50 Hz to 50 kHz < 99 %
20 Hz to 100 kHz < 95 %
20 Hz to 100 kHz < 99 %
20 Hz to 10 MHz < 95 %
20 Hz to 10 MHz < 99 %
(11 to 13.5) MHz
0.27 %
0.31 %
0.36 %
0.42 %
2.9 %
2.9 %
HP 11715A
Frequency Modulation –
Generate
3
DC to 100 kHz Rates
DC to 200 kHz Rates
DC to 10 MHz Rates
(11 to 432) MHz
0.21 %
0.32 %
2.9 %
HP 11715A | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 18 of 21
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
Frequency Modulation –
Measure3
Rate: 20 Hz to 10 kHz
Dev.: ≤ 40 kHz peak
Rate: 50 Hz to 100 kHz
Dev.: ≤ 400 kHz peak
Rate: 20 Hz to 200 kHz
Dev.: ≤ 400 kHz peak
Rate: 50 Hz to 100 kHz
Dev.: ≤ 400 kHz peak
Rate: 20 Hz to 200 kHz
Dev.: ≤ 400 kHz peak
(0.25 to 10) MHz
(10 to 1300) MHz
(10 to 1300) MHz
(10 to 26 500) MHz
(10 to 26 500) MHz
2.0 % + 1 digit
1.1 % + 1 digit
5.0 % + 1 digit
2.7 % + 1 digit
6.3 % + 1 digit
Agilent/HP 8902A
w/ 11722A &
11792A sensors
Plus Agilent/HP
11793A mixer
Phase Modulation – Measure
Rate: 200 Hz to 10 kHz
Rate: 20 Hz to 200 kHz
150 kHz to 10 MHz
10 MHz to 26.5 GHz
4 % + 0.015 rad
5 % + 0.019 rad
HP 8902A
measuring receiver
w/ HP 11792A
sensor
Harmonic Distortion –
Measure
(-99 to 0) dB
20 Hz to 20 kHz
(> 20 to 100) kHz
> 100 kHz to 2.9 GHz
(> 2.9 to 22) GHz
(> 22 to 26.5) GHz
1.2 dB
2.1 dB
3.5 dB
6.1 dB
7.9 dB
HP 8903B audio
analyzer
Spectrum analyzer
AC Voltage Flatness –
Measure3
Relative to 1 kHz
Reference:
(0 to 3) V
100 Hz to 1 MHz
(> 1 to 20) MHz
0.18 % + 0.58R
0.25 % + 0.58R
Thermal converters
& HP 3458A | ||
| 19 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 19 of 21
V. Mechanical
Parameter/Equipment
Range
CMC2, 7, 10 (±)
Comments
Force – Measuring
Equipment3, Tension &
Compression
Up to 300 lbf
0.13 % + 0.58R
Class F weights
Pressure – Measuring
Equipment3
(0 to 100) psia
(> 100 to 500) psig
0.026 % + 0.049 psia
0.096 % + 0.14 psig
Fluke 750PA6
Fluke 750P07
Torque Measuring
Equipment (Wrenches &
Screwdrivers)3
(1 to 10) ozf∙in
(10 to 100) ozf∙in
(5 to 150) lbf∙in
(15 to 150) lbf∙ft
0.32 %
0.82 %
0.53 %
0.31 %
AWS Series IT
transducers &
display
Torque Transducers
(1 to 10) ozf∙in
(10 to 100) ozf∙in
(5 to 150) lbf∙in
(15 to 250) lbf∙ft
0.025 % + 0.58R
0.024 % + 0.58R
0.020 % + 0.58R
0.019 % + 0.58R
Weights, torque
arms, torque wheels
VI. Thermodynamics
Parameter/Equipment
Range
CMC2, 10 (±)
Comments
Temperature – Measure
(-196 to 420) °C
0.048 °C
Direct comparison
Fluke 5616 PRT
Temperature – Measuring
Equipment
(-50 to 160) °C
(0 to 100) °C
(Ambient to 350) °C
0.13 °C
0.062 °C
0.051 °C
Direct comparison
Fluke 5616 PRT
Humidity – Measure3
(10 to 90) % RH
(90 to 95) % RH
1.4 % RH
2.5 % RH
Vaisala
HMI41/HMP46
Humidity – Measuring
Equipment
(11 to 75) % RH
1.3 % RH
Vaisala
HMI41/HMP46 &
humidity salts | to 300 lbf |
| 20 | NIST RP 960-12 | - | See scope document |
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.12) Revised 04/16/2025 Page 21 of 21
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
5 Based on using the standard at the temperature the Fluke 5520A with SC1100 was calibrated (tcal ± 5 °C)
and assuming the instrument is zeroed at least every seven days or when the ambient temperature changes
more than 5 °C. For resistance, a zero calibration is performed at least every 12 hours within ± 1
oC of
use.
6 Based on using the standard at the temperature the HP 3458A was calibrated (tcal ± 5 °C) and an auto-
calibration (ACAL) was performed within the previous 24 hours (± 1 °C of ambient temperature).
7 In the statement of CMC; the value is defined as the percentage of reading unless otherwise noted. In the
statement of CMC, R is the numerical value of the resolution of the device. In the statement of CMC, L
is the numerical value of the nominal length of the device measured in inches.
8 CMC uncertainties are best case at 1 kHz.
9 This scope meets A2LA’s P112 Flexible Scope Policy.
10 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
11 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration. | ||
| 22 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Cascade Engineering ServicesRedmond, WA · ~2 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ThermetricsSeattle, WA · ~17 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Eustis Co., Inc./Pyrocom CalibrationLynnwood, WA · ~22 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Robb Precision Tool ServicesLynnwood, WA · ~22 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Global Calibration ServicesTukwila, WA · ~25 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994