Registers refreshed 2026-11-20.See refresh dates
Poland

Centrum Badań i Dozoru

ul. Fabryczna 20, 41-404, Mysłowice, Poland

Visit website
PCA AB 1348ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
24
PCA certificate
1
Sites in our directory
2
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 24 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO10
ISO 3154Stranded wire ropes for mine hoisting - Technical delivery requirements
ISO 3452-1Non-destructive testing - Penetrant testing - Part 1: General principles
ISO 6892-1Metallic materials - Tensile testing - Part 1: Method of test at room temperature
ISO 7800Metallic materials - Wire - Simple torsion test
ISO 7801Metallic materials - Wire - Reverse bend test
ISO 9934-1Non-destructive testing - Magnetic particle testing - Part 1: General principles
ISO 16809Non-destructive testing - Ultrasonic thickness determination
ISO 16810Non-destructive testing - Ultrasonic testing - General principles
ISO 17637Non-destructive testing of welds - Visual testing of fusion-welded joints
ISO 17640Non-destructive testing of welds - Ultrasonic testing - Techniques, testing levels, and assessment
EN8
EN 10160Ultrasonic testing of steel flat product of thickness equal to or greater than 6 mm (reflection method)
EN 10228-3Non-destructive testing of steel forgings - Part 3: Ultrasonic testing of ferritic or martensitic steel forgings
EN 12385-1
EN 12927-8
EN 13018Non-destructive testing - Visual testing - General principles
EN 14127
EN 17640
EN 50321-1
IEC4
IEC 60832-1
IEC 60903
IEC 61111
IEC 61243-1
Other standards2
PN-G-46603
PN-G-46604

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.

Scope as published by PCA

3 lines
PCA

ISO/IEC 17025

Active

AB 1348

The scope document we hold says it is valid until 2028-07-31.

View on PCA

Accredited scope, certificate AB 1348

LineMethodMatrixRange
1-środki ochrony osobistej; wyroby i materiały konstrukcyjne
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1348 Scope of accreditation No. AB 1348 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No. AB 1348 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 14 z/of 01.07.2024 KIEROWNIK DZIAŁU AKREDYTACJI BADAŃ MECHANICZNYCH I FIZYCZNYCH MARIA SZAFRAN Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1348 z dnia 18.05.2022 r. Cykl akredytacji od 01.07.2024 r. do 31.07.2028 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No. AB 1348 of 18.05.2022 Accreditation cycle from 01.07.2024 to 31.07.2028 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No. 14, 01.07.2024 1/4 Nazwa i adres / Name and address CENTRUM BADAŃ I DOZORU Sp. z o.o. ul. Lędzińska 8 43-143 Lędziny LABORATORIUM OŚRODKA RZECZOZNAWSTWA I DOZORU URZĄDZEŃ GÓRNICZYCH ul. Fabryczna 20 41-404 Mysłowice Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - E/19 - Badania elektryczne i elektroniczne: środki ochrony osobistej / Electric and electronic tests: perso nal protection equipment - J/8 - L/8 - Badania mechaniczne, badania metalograficzne: wyroby i materiały konstrukcyjne / Mechanical tests, metallographic tests: construction products and materials - Badania nieniszczące: wyroby i materiały konstrukcyjne / Non -destructive tests: construction products and materials Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl AB 1348
-
2PN-EN 17640:2011; PN-EN ISO 17640:2019-01; PN-EN ISO 16810:2014-06; PN-EN 10160:2001; PN-EN ISO 16810:2014-06; PN-EN 10228-3:2000; PN-EN ISO 16810:2014-06; PN-EN 10228-3:2016-07; PN-EN 14127:2011; PN-EN ISO 16809:2019-08; PN-EN ISO 9934-1:2017-02; PN-EN ISO 3452-1:2021-12; PN-EN 13018:2004; PN-EN 13018:2016-04; PN-EN ISO 17637:2017-02; PN-EN 12927-8:2006; PN-EN 12927:2019-07; PN-G-46603:1992; PN-G-46604:1992; PN-ISO 3154:1997 pkt. 5.2.2; PN-EN ISO 6892-1:2016-09; PN-EN ISO 6892-1:2020-05; PN-ISO 7800:1996; PN-ISO 7801:1996; PN-ISO 3154:1997 pkt. 5.1.1; PN-EN 12385-1:2009 Metoda 1; PN-ISO 3154:1997 Metoda BZłącza spawane materiałów metalowych; Wyroby stalowe płaskie; Odkuwki stalowe; Wyroby metalowe; Wyroby i materiały metalowe ferromagnetyczne w tym: odlewy, odkuwki, złącza spawane, blachy; Wyroby i materiały metalowe w tym: odlewy, odkuwki, złącza spawane, blachy; Wyroby i materiały metalowe w tym: odlewy, odkuwki, blachy; Złącza spawane materiałów metalowych; Liny stalowe i stalowo-gumowe; Druty; Liny stalowe0.5 to 300 mm
3PN-EN 50321-1:2018-05; PN-EN 60903:2006; PN-EN 61111:2009; PN-EN 60832-1:2010; PN-EN IEC 61243-1:2022-01-1 to 100 kV

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Fabryczna 20, Mysłowice, 41-404, PL

50.24147, 19.14145

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the PCA register on .