Technologie NDT
ul Pyskowicka 23, 41-807, Zabrze, Poland
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Technologie NDT?
Claim this profile to keep it accurate.
Register record
- PCARefreshed
- AB 1425Active
Certificates and scope
1ISO/IEC 17025
ActiveAB 1425
The scope document we hold says it is valid until 2029-04-01.
Accredited scope, certificate AB 1425
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | ndt | - | Metal | - |
| 2 | ndt | PN-EN ISO 5579:2014-02; PN-EN ISO 10893-6:2019-04; PN-EN ISO 17636-1:2023-02; PN-EN ISO 17636-2:2023-04; PN-EN 10160:2001; PN-EN ISO 16810:2014-06; PN-EN ISO 17640:2019-01; PN-EN ISO 10863:2020-12; PN EN ISO 13588:2019-04; PN-EN ISO 16828:2014-06; PN-EN 12680-1:2005; PN-EN 10228-3:2016-07; PN-EN ISO 10893-8:2011; PN-EN ISO 10893-9:2011; PN-EN ISO 16809:2019-08; PN-EN ISO 9934-1:2017-02; PN-EN ISO 17638:2017-01; PN-EN 10228-1:2016-07; PN-EN ISO 10893-5:2011; PN-EN ISO 3452-1:2021-12; PN-EN 10228-2:2016-07; PN-EN 1371-1:2012; PN-EN ISO 10893-4:2011; PN-EN 13018:2016-04; PN-EN ISO 17637:2017-02 | Wyroby i materiały metalowe; Rury stalowe; Złącza spawane materiałów metalowych; Wyroby stalowe płaskie; Odlewy staliwne; Odkuwki stalowe; Rury stalowe; Wyroby i materiały metalowe ferromagnetyczne; Złącza spawane materiałów i wyrobów ferromagnetycznych; Odkuwki stalowe; Rury stalowe ferromagnetyczne; Odlewy | 0.5 to 300 mm |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Echo-Test TEAMRuda Śląska · ~7 kmPCAShares 1 accredited test methodEN ISO 3452-1:2021-12
- Komplex90 Badanie MateriałówMikołów · ~18 kmPCAShares 1 accredited test methodEN ISO 3452-1:2021-12
- Centrum Badań i DozoruMysłowice · ~26 kmPCAShares 1 accredited test methodEN ISO 3452-1:2021-12
- Laboratorium Spawalnicze "GAMMA-MONTEX"Częstochowa · ~61 kmPCAShares 1 accredited test methodEN ISO 3452-1:2021-12
- Świętokrzyskie Centrum Badania JakościOstrowiec Świętokrzyski · ~198 kmPCAShares 1 accredited test methodEN ISO 3452-1:2021-12
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.