Deibel Labs of Kansas
1500 Hayes Drive, suite 10, 66502, Manhattan, KS, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Deibel Labs of Kansas?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 2833.23Active
- 2833.17Active
Accredited standards
2Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
AOAC 966.23Name not checked yet
ISO/IEC 17025:2017; AOAC 966.23; FDA/BAM: Ch. 3; AOAC 990.12; AOAC 986.33; AOAC 989.10; FDA/BAM: Ch. 14; AOAC 966.24; FDA/BAM: Ch. 4; AOAC 991.14; FDA/BAM: Ch. 4; AOAC-RI 121805; AOAC 2003.01; CMMEF 9.62; CMMEF 10.51; AOAC 2019.10; APAC-RI-121803; AOAC 121402; AOAC 2004.02; FDA/BAM: Ch. 10 (Modified); AOAC 081401; AOAC RI 030502; AOAC 2004.06; AOAC-RI 981202; FDA/BAM: Ch. 5 (Modified); AOAC 2020.02; AOAC-RI 121802
AOAC 966.23; FDA/BAM: Ch. 3; AOAC 990.12; AOAC 986.33; AOAC 989.10; FDA/BAM: Ch. 14; AOAC 966.24; FDA/BAM: Ch. 4; AOAC 991.14; FDA/BAM: Ch. 4; AOAC-RI 121805; AOAC 2003.01; CMMEF 9.62; CMMEF 10.51; AOAC 2019.10; APAC-RI-121803; AOAC 121402; AOAC 2004.02; FDA/BAM: Ch. 10 (Modified); AOAC 081401; AOAC RI 030502; AOAC 2004.06; AOAC-RI 981202; FDA/BAM: Ch. 5 (Modified); AOAC 2020.02; AOAC-RI 121802
AOAC 2003.09Name not checked yet
AOAC 2003.09; AOAC 2013.02; AOAC-RI 081201; AOAC 2004.03; AOAC 975.55; FDA/BAM: Ch.12; AOAC 2003.07; AOAC 2003.08; AOAC 2003.11; AOAC 997.02; FDA/BAM 7th Ed., Ch. 18; AOAC 2014.05
AOAC 2003.09; AOAC 2013.02; AOAC-RI 081201; AOAC 2004.03; AOAC 975.55; FDA/BAM: Ch.12; AOAC 2003.07; AOAC 2003.08; AOAC 2003.11; AOAC 997.02; FDA/BAM 7th Ed., Ch. 18; AOAC 2014.05
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active2833.23
The scope document we hold says it is valid until 2027-02-28.
Accredited scope, certificate 2833.23
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | biological | AOAC 966.23; FDA/BAM: Ch. 3; AOAC 990.12; AOAC 986.33; AOAC 989.10; FDA/BAM: Ch. 14; AOAC 966.24; FDA/BAM: Ch. 4; AOAC 991.14; FDA/BAM: Ch. 4; AOAC-RI 121805; AOAC 2003.01; CMMEF 9.62; CMMEF 10.51; AOAC 2019.10; APAC-RI-121803; AOAC 121402; AOAC 2004.02; FDA/BAM: Ch. 10 (Modified); AOAC 081401; AOAC RI 030502; AOAC 2004.06; AOAC-RI 981202; FDA/BAM: Ch. 5 (Modified); AOAC 2020.02; AOAC-RI 121802 | food products, surface sponges, and swabs | - |
| 2 | food | AOAC 2003.09; AOAC 2013.02; AOAC-RI 081201; AOAC 2004.03; AOAC 975.55; FDA/BAM: Ch.12; AOAC 2003.07; AOAC 2003.08; AOAC 2003.11; AOAC 997.02; FDA/BAM 7th Ed., Ch. 18; AOAC 2014.05 | - | - |
| 3 | biological | ISO/IEC 17025:2017; A2LA R204 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active2833.17
The scope document we hold says it is valid until 2027-02-28.
Accredited scope, certificate 2833.17
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | biological | ISO/IEC 17025:2017; AOAC 966.23; FDA/BAM: Ch. 3; AOAC 990.12; AOAC 986.33; AOAC 989.10; FDA/BAM: Ch. 14; AOAC 966.24; FDA/BAM: Ch. 4; AOAC 991.14; FDA/BAM: Ch. 4; AOAC-RI 121805; AOAC 2003.01; CMMEF 9.62; CMMEF 10.51; AOAC 2019.10; APAC-RI-121803; AOAC 121402; AOAC 2004.02; FDA/BAM: Ch. 10 (Modified); AOAC 081401; AOAC RI 030502; AOAC 2004.06; AOAC-RI 981202; FDA/BAM: Ch. 5 (Modified); AOAC 2020.02; AOAC-RI 121802 | Food products | - |
| 2 | food | AOAC 2003.09; AOAC 2013.02; AOAC-RI 081201; AOAC 2004.03; AOAC 975.55; FDA/BAM: Ch.12; AOAC 2003.07; AOAC 2003.08; AOAC 2003.11; AOAC 997.02; FDA/BAM 7th Ed., Ch. 18; AOAC 2014.05 | - | - |
| 3 | biological | ISO/IEC 17025:2017; A2LA R204 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Silliker Inc. dba Merieux NutriSciences SpringfieldSpringfield, MO · ~361 kmA2LAShares 3 accredited methods and materialsAOAC 2003.09AOAC 966.23Food products
- Eurofins Microbiology Laboratories, Inc. - MilwaukeeNew Berlin, WI · ~825 kmA2LAShares 3 accredited methods and materialsAOAC 2003.09AOAC 966.23Food products
- Silliker, Inc. dba Merieux NutriSciences OhioColumbus, OH · ~1,165 kmA2LAShares 3 accredited methods and materialsAOAC 2003.09AOAC 966.23Food products
- Deibel Laboratories of PennsylvaniaAllentown, PA · ~1,803 kmA2LAShares 3 accredited methods and materialsAOAC 2003.09AOAC 966.23Food products
- Eurofins Microbiology Laboratories, Inc. - Los AngelesTustin, CA · ~1,989 kmA2LAShares 3 accredited methods and materialsAOAC 2003.09AOAC 966.23Food products
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.