Yaskawa Electric Corporation Products Certification Center
2-1 Kurosakishiroishi, Yahatanishi-ku, Kitakyushu, 806-0004, Japan, Kitakyushu, Japan
Visit website- Accredited standards
- 19
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 19 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC7
IEC 60034-1
IEC 61131-2
IEC 61131-6
IEC 61784-3
IEC 61800-5-2
IEC 61800-5-3
IEC 62061
IEC 61000 series4
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 61000-6-7
IEC 61000-6-8
Other standards8
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements
EN 50370-1
EN 50370-2
FCC PART 15Radio Frequency Devices
ISO 16090-1Machine tools safety - Machining centres, milling machines, transfer machines - Part 1: Safety requirements
ISO 23125Machine tools - Safety - Turning machines
IEC 61000-6-4; EN 61000-6-4; IEC 61000-6-7; EN 61000-6-7; IEC 61000-6-8; EN 61000-6-8; IEC 61131-2; EN 61131-2; IEC 61131-6; EN 61131-6; IEC 61784-3; EN 61784-3; IEC 61800-5-2; EN 61800-5-2; IEC 61800-5-3; IEC 62061; EN IEC 62061; IEC 60034-1; EN 60034-1; EN 50370-1; EN 50370-2; ISO 16090-1; EN ISO 16090-1; ISO 23125; EN ISO 23125
IEC 62061(EMC part only); EN 62061 (EMC part only); IEC 62061:2005/A2:2015 (EMC part only); EN 62061:2005/A2:2015 (EMC part only); ANSI C63.4:2014
CFR 47, FCC Part 15B; ANSI C63.4:2014; ANSI C63.4a:2017; CISPR 11; EN 55011; CISPR 11:2009/A1:2010; EN 55011:2009/A1:2010; CISPR 11:2015; EN 55011:2016; CISPR 11:2015/A1:2016; EN 55011:2016/A1:2017; CISPR 11:2015/A2:2019; EN 55011:2016/A11:2020; EN 55011:2016/A2:2021; CISPR 11:2024; CISPR 32; EN 55032; CISPR 32:2012; EN 55032:2012; CISPR 32:2015; EN 55032:2015; CISPR 32:2015/A1:2019; EN 55032:2015/A11:2020; EN 55032:2015/A1:2020; IEC 61000-4-2; EN 61000-4-2; EN IEC 61000-4-2; IEC 61000-4-2:2008; EN 61000-4-2:2009
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active4256.01
The scope document we hold says it is valid until 2027-06-30.
Accredited scope, certificate 4256.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CFR 47, FCC Part 15B; ANSI C63.4:2014; ANSI C63.4a:2017; CISPR 11; EN 55011; CISPR 11:2009/A1:2010; EN 55011:2009/A1:2010; CISPR 11:2015; EN 55011:2016; CISPR 11:2015/A1:2016; EN 55011:2016/A1:2017; CISPR 11:2015/A2:2019; EN 55011:2016/A11:2020; EN 55011:2016/A2:2021; CISPR 11:2024; CISPR 32; EN 55032; CISPR 32:2012; EN 55032:2012; CISPR 32:2015; EN 55032:2015; CISPR 32:2015/A1:2019; EN 55032:2015/A11:2020; EN 55032:2015/A1:2020; IEC 61000-4-2; EN 61000-4-2; EN IEC 61000-4-2; IEC 61000-4-2:2008; EN 61000-4-2:2009 | - | to 18 GHz |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4256.01) 07/30/2025 Page 2 of 4
Test: Test Method(s) 1:
Radiated Immunity IEC 61000-4-3; EN 61000-4-3;
IEC 61000-4-3:2006/A2:2010;
EN 61000-4-3:2006/A2:2010; IEC 61000-4-3:2020;
EN IEC 61000-4-3:2020
Electrical Fast Transient/Burst IEC 61000-4-4; EN 61000-4-4; IEC 61000-4-4:2012;
EN 61000-4-4:2012
Surge Immunity IEC 61000-4-5; EN 61000-4-5; IEC 61000-4-5:2014;
EN 61000-4-5:2014; IEC 61000-4-5:2014/A1:2017;
EN 61000-4-5:2014/A1:2017
Conducted Immunity IEC 61000-4-6; EN 61000-4-6; IEC 61000-4-6:2013;
EN 61000-4-6:2014; IEC 61000-4-6:2023;
EN IEC 61000-4-6:2023
Power Frequency Magnetic Field IEC 61000-4-8 (excluding short duration mode);
EN 61000-4-8 (excluding short duration mode);
IEC 61000-4-8:2009; EN 61000-4-8:2010
Voltage Dips and Interruptions IEC 61000-4-11; EN 61000-4-11;
IEC 61000-4-11:2004; EN 61000-4-11:2004;
IEC 61000-4-11:2020; EN IEC 61000-4-11:2020
Low Frequency Conducted Immunity IEC 61000-4-16; EN 61000-4-16;
IEC 61000-4-16:2015; EN 61000-4-16:2016
Generic and Product Family Standards
CISPR 35; EN 55035 (excluding clause 4.2.7);
CISPR 35:2016; EN 55035:2017;
EN 55035:2017/A11:2020; IEC 61800-3;
EN 61800-3 (Current ≤ 16A);
IEC 61800-3:2004/A1:2011;
EN 61800-3:2004/A1:2012;
IEC 61800-3:2017; EN IEC 61800-3:2018;
IEC 61800-3:2022; EN IEC 61800-3:2023;
IEC 61326-3-1; EN 61326-3-1; IEC 61326-3-1:2008;
EN 61326-3-1:2008; IEC 61326-3-1:2017;
EN 61326-3-1:2017;
IEC 61000-6-1; EN 61000-6-1; IEC 61000-6-1:2005;
EN 61000-6-1:2007; IEC 61000-6-1:2016,
EN IEC 61000-6-1:2019; IEC 61000-6-2;
EN 61000-6-2; IEC 61000-6-2:2005;
EN 61000-6-2:2005; IEC 61000-6-2:2016;
EN IEC 61000-6-2:2019;
IEC 61000-6-3; EN 61000-6-3;
IEC 61000-6-3:2006/A1:2010;
EN 61000-6-3:2007/A1:2011; IEC 61000-6-3:2020;
EN IEC 61000-6-3:2021; | ||
| 3 | IEC 61000-6-4; EN 61000-6-4; IEC 61000-6-7; EN 61000-6-7; IEC 61000-6-8; EN 61000-6-8; IEC 61131-2; EN 61131-2; IEC 61131-6; EN 61131-6; IEC 61784-3; EN 61784-3; IEC 61800-5-2; EN 61800-5-2; IEC 61800-5-3; IEC 62061; EN IEC 62061; IEC 60034-1; EN 60034-1; EN 50370-1; EN 50370-2; ISO 16090-1; EN ISO 16090-1; ISO 23125; EN ISO 23125 | - | - |
| 4 | IEC 62061(EMC part only); EN 62061 (EMC part only); IEC 62061:2005/A2:2015 (EMC part only); EN 62061:2005/A2:2015 (EMC part only); ANSI C63.4:2014 | - | to 18000 MHz |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests or types of tests to which this accreditation applies, please refer to the laboratory’s «field» Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
YASKAWA ELECTRIC CORPORATION
PRODUCTS CERTIFICATION CENTER
Kitakyushu, Japan
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 30th day of July 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 4256.01
Valid to June 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
2-1 Kurosakishiroishi, Yahatanishi-ku, Kitakyushu, 806-0004, Japan, Kitakyushu, JP
33.88300, 130.87490
Open in MapsLabs with overlapping accredited scope in Japan
- Cosmos CorporationMatsusaka-shi, Mie · ~525 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- UL JapanIse-shi, Mie · ~543 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- UL Japan, Inc., Shonan EMCKanagawa · ~796 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- UL Japan, Inc. - Kashima EMCChiba-ken, 289-0341 · ~861 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- TOYO EMC EngineeringTsukuba · ~873 kmA2LAShares 1 accredited test methodIEC 61000-6-4
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.