Radian Research
3852 Fortune Drive, 47905, Lafayette, IN, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 3784.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | RS-703-A; RS-933 | - | 16.7 to 33.3 kVAh |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3784.01) 08/19/2025 Page 3 of 4
Parameter/Equipment
Range
CMC2, 3, 4 (±)
Comments
AC Power – Generate,
Watts
12 W to 120 kW
Over:
(120 to 600) V @ 60 Hz
(120 to 480) V @ 50 Hz
(0.2 to 200) A
(-60 to 60)° Phase Angle
(5 to 1000) s Test Time
(50 to 60) Hz
10 μW/VA
Alternately:
0.001 % IV @ 0° Phase
Angle
0.0016 % IV @ ± 60°
Phase Angle
RS-703A and RS-
933 calibration
systems
AC Power – Generate,
VAR
12 W to 120 kW
Over:
(120 to 600) V @ 60 Hz
(120 to 480) V @ 50 Hz
(0.2 to 200) A
(-90 to 60)° Phase Angle
(5 to 1000) s Test Time
(50 to 60) Hz
19 μVAR/VA
RS-703A and RS-
933 calibration
systems
AC Power – Generate,
VA
12 W to 120 kW
Over:
(120 to 600) V @ 60 Hz
(120 to 480) V @ 50 Hz
(0.2 to 200) A
(5 to 1000) s Test Time
(50 to 60) Hz
10 μVA/VA
Alternately:
0.001 % IV @ 0° Phase
Angle
0.0016 % IV @ ± 60°
Phase Angle
RS-703A and RS-
933 calibration
systems
AC Power – Measure,
Watts
12 W to 120 kW
Over:
(120 to 600) V @ 60 Hz
(120 to 480) V @ 50 Hz
(0.2 to 200) A
(-60 to 60)° Phase Angle
(5 to 1000) s Test Time
(50 to 60) Hz
9 μW/VA
Alternately:
0.0009 % IV @ 0° Phase
Angle
0.0016 % IV @ ± 60°
Phase Angle
RD-22 bank | 12 to 120000 W |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3784.01) 08/19/2025 Page 4 of 4
Parameter/Equipment
Range
CMC2, 3, 4 (±)
Comments
AC Power – Measure,
VAR
(12 to 120) VAR
Over:
(120 to 600) V @ 60 Hz
(120 to 480) V @ 50 Hz
(0.2 to 200) A
(-90 to 60)° Phase Angle
(5 to 1000) s Test Time
(50 to 60) Hz
19 μVAR/VA
RD-22 bank
AC Power – Measure,
VA
12 VA to 120 kVA
Over:
(120 to 600) V @ 60 Hz
(120 to 480) V @ 50 Hz
(0.2 to 200) A
(5 to 1000) s Test Time
(50 to 60) Hz
9 μVA/VA
Alternately:
0.0009 % IV @ 0° Phase
Angle
0.0016 % IV @ ± 60°
Phase Angle
RD-22 bank
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
4 In the statement of the CMC, IV represents Indicated Value.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | 12 to 120000 VA |
| 5 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Magnetic InstrumentationIndianapolis, IN · ~96 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Quality Control Sales and ServicesIndianapolis, IN · ~96 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Endress+HauserGreenwood, IN · ~112 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Illiana Instrumentation ServiceSchererville, IN · ~127 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Richard J. Bagan, Inc. D.B.A. Montech USAColumbia City, IN · ~144 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.