Radian Research

3852 Fortune Drive, 47905, Lafayette, IN, United States

Visit website
A2LA 3784.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 3784.01 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2RS-703-A; RS-933-16.7 to 33.3 kVAh
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3784.01) 08/19/2025 Page 3 of 4 Parameter/Equipment Range CMC2, 3, 4 (±) Comments AC Power – Generate, Watts 12 W to 120 kW Over: (120 to 600) V @ 60 Hz (120 to 480) V @ 50 Hz (0.2 to 200) A (-60 to 60)° Phase Angle (5 to 1000) s Test Time (50 to 60) Hz 10 μW/VA Alternately: 0.001 % IV @ 0° Phase Angle 0.0016 % IV @ ± 60° Phase Angle RS-703A and RS- 933 calibration systems AC Power – Generate, VAR 12 W to 120 kW Over: (120 to 600) V @ 60 Hz (120 to 480) V @ 50 Hz (0.2 to 200) A (-90 to 60)° Phase Angle (5 to 1000) s Test Time (50 to 60) Hz 19 μVAR/VA RS-703A and RS- 933 calibration systems AC Power – Generate, VA 12 W to 120 kW Over: (120 to 600) V @ 60 Hz (120 to 480) V @ 50 Hz (0.2 to 200) A (5 to 1000) s Test Time (50 to 60) Hz 10 μVA/VA Alternately: 0.001 % IV @ 0° Phase Angle 0.0016 % IV @ ± 60° Phase Angle RS-703A and RS- 933 calibration systems AC Power – Measure, Watts 12 W to 120 kW Over: (120 to 600) V @ 60 Hz (120 to 480) V @ 50 Hz (0.2 to 200) A (-60 to 60)° Phase Angle (5 to 1000) s Test Time (50 to 60) Hz 9 μW/VA Alternately: 0.0009 % IV @ 0° Phase Angle 0.0016 % IV @ ± 60° Phase Angle RD-22 bank
12 to 120000 W
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3784.01) 08/19/2025 Page 4 of 4 Parameter/Equipment Range CMC2, 3, 4 (±) Comments AC Power – Measure, VAR (12 to 120) VAR Over: (120 to 600) V @ 60 Hz (120 to 480) V @ 50 Hz (0.2 to 200) A (-90 to 60)° Phase Angle (5 to 1000) s Test Time (50 to 60) Hz 19 μVAR/VA RD-22 bank AC Power – Measure, VA 12 VA to 120 kVA Over: (120 to 600) V @ 60 Hz (120 to 480) V @ 50 Hz (0.2 to 200) A (5 to 1000) s Test Time (50 to 60) Hz 9 μVA/VA Alternately: 0.0009 % IV @ 0° Phase Angle 0.0016 % IV @ ± 60° Phase Angle RD-22 bank ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification. 4 In the statement of the CMC, IV represents Indicated Value. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
12 to 120000 VA
5ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

3852 Fortune Drive, Lafayette, IN, 47905, US

40.41912, -86.89190

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.