ALPS ALPINE CO., LTD. EMC TEST LAB Furukawa
6-3-36 Furukawa Nakazato, Osaki-City, Miyagi-Prefecture , 989-6181, Japan, Osaki-City, Miyagi-Prefecture, Japan
- Accredited standards
- 7
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 7 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methodsSome clausesExclusion
Limits written next to it
ISO 11452-4 (2005, 2011, 2020 [excluding clause 6.2])
ISO 11452-4 (2005, 2011, 2020 [excluding clause 6.2])
ISO 11452-4 (excluding clause 6.2)
ISO 11452-4 (excluding clause 6.2)
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fieldsExclusion
Limits written next to it
ISO 11452-8 (2015) (excluding section 8.3.2)
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 7637-2; ISO 7637-3; ISO 16750-2; SAE J1113-25; ANSI C63
ISO/IEC 17025:2017; ISO 10605; ISO 11452-4; ISO 11452-2; ISO 11452-8
Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-06.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active2015.01
The scope document we hold says it is valid until 2027-02-28.
Accredited scope, certificate 2015.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ISO 10605; ISO 11452-4; ISO 11452-2; ISO 11452-8 | - | - |
| 2 | ISO 7637-2; ISO 7637-3; ISO 16750-2; SAE J1113-25; ANSI C63 | - | to 40000 MHz |
| 3 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
6-3-36 Furukawa Nakazato, Osaki-City, Miyagi-Prefecture , 989-6181, Japan, Osaki-City, Miyagi-Prefecture, JP
38.57760, 140.95597
Open in MapsLabs with overlapping accredited scope in Japan
- OKI ENGINEERING CO.,Honjo-shi, Saitama-ken · ~303 kmA2LAShares 2 accredited test methodsISO 10605ISO 7637-2
- UL Japan, Inc. - Kashima EMCChiba-ken, 289-0341 · ~335 kmA2LAShares 2 accredited test methodsISO 10605ISO 7637-2
- TOYO Corporation Calibration LaboratoryTokyo 135-0042 · ~339 kmA2LAShares 2 accredited test methodsISO 10605ISO 7637-2
- UL Japan, Inc. Automotive Technology CenterMiyoshi-shi, Aichi · ~517 kmA2LAShares 2 accredited test methodsISO 10605ISO 7637-2
- OHTAMA CALIBRATION SERVICE Co.,Kanagawa · ~377 kmA2LAShares 1 accredited test methodISO 10605
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.