Registers refreshed 2026-11-08.See refresh dates
United States

Northrop Grumman Systems Corporation, Strategic Space Systems Division

One Space Park, GSEP13BA, Building S room 2049, 90278, Redondo Beach, CA, United States

Visit website
A2LA 3005.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
12
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 12 scope lines.

A2LA certificate 3005.01 · 12 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSLI Z540-1-1994; ANSI/NCSLI Z540.3-2006-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3005.01) 8/21/2024 Page 2 of 11 Parameter/Range Frequency CMC2, 3, 6 (±) Comments AC Voltage – Measure & Generate 10 mV 100 mV 1 V 10 V 100 V 1000 V 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 40 Hz 100 Hz 1 kHz 10 kHz 20 kHz 97 µV/V 89 µV/V 88 µV/V 88 µV/V 0.017 % 0.037 % 44 µV/V 30 µV/V 22 µV/V 22 µV/V 43 µV/V 0.019 % 26 µV/V 9.5 µV/V 7.0 µV/V 7.5 µV/V 12 µV/V 47 µV/V 26 µV/V 7.7 µV/V 6.8 µV/V 6.1 µV/V 8.7 µV/V 41 µV/V 26 µV/V 8.5 µV/V 7.6 µV/V 8.1 µV/V 11 µV/V 22 µV/V 20 µV/V 18 µV/V 18 µV/V 19 µV/V Fluke 792 AC standard & Fluke 8588A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3005.01) 8/21/2024 Page 3 of 11 II. Electrical – RF/Microwave Parameter/Range Frequency CMC2 (±) Comments RF Attenuation (Transmission S 21/S12) – (0 to 20) dB Fixed/Variable Coaxial 2.4 mm 3.5 mm WR-22 WR-15 WR-10 (20 to 40) dB Fixed/Variable Coaxial 2.4 mm 3.5 mm WR-22 WR-15 WR-10 (0.05 to 0.5) GHz (0.5 to 2) GHz (2 to 26.5) GHz (26.5 to 50) GHz (0.05 to 0.5) GHz (0.5 to 2) GHz (2 to 26.5) GHz (33 to 50) GHz (50 to 75) GHz (75 to 110) GHz (0.05 to 0.5) GHz (0.5 to 2) GHz (2 to 26.5) GHz (26.5 to 50) GHz (0.05 to 0.5) GHz (0.5 to 2) GHz (2 to 26.5) GHz (33 to 50) GHz (50 to 75) GHz (75 to 110) GHz 0.040 dB 0.040 dB 0.18 dB 0.31 dB 0.050 dB 0.050 dB 0.13 dB 0.10 dB 0.10 dB 0.11 dB 0.030 dB 0.040 dB 0.47 dB 1.9 dB 0.29 dB 0.29 dB 0.14 dB 0.070 dB 0.080 dB 0.12 dB Keysight PNA-X system network analyzer HP 8510C system network analyzer Keysight PNA-X system network analyzer HP 8510C system network analyzer
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3005.01) 8/21/2024 Page 4 of 11 Parameter/Range Frequency CMC2, 3 (±) Comments RF Attenuation (Transmission S21/S12) – (cont) (40 to 50) dB Fixed/Variable Coaxial 2.4 mm 3.5mm WR-22 WR-15 WR-10 (0.05 to 0.5) GHz (0.5 to 2) GHz (2 to 26.5) GHz (26.5 to 50) GHz (0.05 to 0.5) GHz (0.5 to 2) GHz (2 to 26.5) GHz (33 to 50) GHz (50 to 75) GHz (75 to 110) GHz 0.30 dB 0.050 dB 0.47 dB 1.9 dB 0.10 dB 0.060 dB 0.14 dB 0.18 dB 0.73 dB 0.68 dB Keysight PNA-X system network analyzer HP 8510C system network analyzer RF Power – Coaxial Power Sensor 1 mW Waveguide Power Sensor Q-Band System @ 50 GHz V-Band System @ 75 GHz W-Band System @ 95 GHz (40 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 30) MHz (30 to 300) MHz 300 MHz to 1 GHz (1 to 8) GHz (8 to 15) GHz (15 to 18) GHz (18 to 22) GHz (22 to 26.5) GHz (26.5 to 40) GHz (40 to 45) GHz (45 to 50) GHz (33 to 50) GHz (50 to 75) GHz (92 to 98) GHz 2.0 % 1.3 % 1.3 % 1.3 % 1.3 % 1.2 % 1.0 % 1.0 % 1.2 % 1.9 % 2.5 % 5.1 % 4.8 % 5.0 % 2.6 % 2.2 % 3.9 % NGC universal auto power system with power sensors & thermistor mounts NGC bench power system with waveguide power sensors
40 to 50 dB
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3005.01) 8/21/2024 Page 5 of 11 Parameter/Range Frequency CMC2, 3 (±) Comments VSWR Gamma (Reflection S11/S22) – (0 to 0.5) Reflection Coefficient Fixed/Variable Coaxial 2.4 mm 3.5 mm WR-22 WR-15 WR-10 (0.5 to 0.8) Reflection Coefficient Fixed/Variable Coaxial 2.4 mm 3.5 mm WR-22 WR-15 WR-10 (0.05 to 0.5) GHz (0.5 to 2.0) GHz (2.0 to 26.5) GHz (26.5 to 50.0) GHz (0.05 to 0.5) GHz (0.5 to 2.0) GHz (2.0 to 26.5) GHz (33 to 50) GHz (50 to 75) GHz (75 to 110) GHz (0.05 to 0.5) GHz (0.5 to 2.0) GHz (2.0 to 26.5) GHz (26.5 to 50.0) GHz (0.05 to 0.5) GHz (0.5 to 2.0) GHz (2.0 to 26.5) GHz (33 to 50) GHz (50 to 75) GHz (75 to 110) GHz 0.97 % 0.97 % 1.6 % 2.0 % 0.49 % 0.49 % 0.75 % 0.60 % 0.80 % 1.0 % 1.0 % 1.0 % 1.7 % 2.1 % 0.60 % 0.60 % 1.2 % 0.90 % 1.5 % 1.7 % Keysight PNA-X system network analyzer HP 8510C system network analyzer Keysight PNA-X system network analyzer HP 8510C system network analyzer
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3005.01) 8/21/2024 Page 6 of 11 Parameter/Range Frequency CMC2, 3 (±) Comments VSWR Gamma (Reflection S11/S22) – (cont) (0.8 to 1.0) Reflection Coefficient Fixed/Variable Coaxial 2.4 mm 3.5 mm WR-22 WR-15 WR-10 (0.05 to 0.5) GHz (0.5 to 2.0) GHz (2.0 to 26.5) GHz (26.5 to 50.0) GHz (0.05 to 0.5) GHz (0.5 to 2.0) GHz (2.0 to 26.5) GHz (33 to 50) GHz (50 to 75) GHz (75 to 110) GHz 1.2 % 1.2 % 2.3 % 2.9 % 0.90 % 0.90 % 2.3 % 1.1 % 2.0 % 2.3 % Keysight PNA-X system network analyzer HP 8510C system network analyzer
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3005.01) 8/21/2024 Page 7 of 11 Parameter/Range Frequency CMC2 (±) Comments Noise Figure & Excess Noise Ratio – Coaxial APC-7 3.5 mm 2.4 mm Waveguide WR-42 WR-28 WR-22 10 MHz to 1 GHz (1 to 3) GHz (3 to 5) GHz (5 to 9) GHz (9 to 11) GHz (11 to 13) GHz (13 to 18) GHz 10 MHz to 6 GHz (6 to 10) GHz (10 to 20) GHz (20 to 26.5) GHz (1 to 6) GHz (6 to 10) GHz (10 to 20) GHz (20 to 26) GHz (26 to 33) GHz (33 to 40) GHz (40 to 44) GHz (44 to 50) GHz (18 to 20) GHz (20 to 22) GHz (22 to 24) GHz (24 to 26) GHz (26.5 to 28) GHz (28 to 30) GHz (30 to 35) GHz (35 to 40) GHz (35 to 40) GHz (40 to 44) GHz (44 to 48) GHz 0.16 dB 0.16 dB 0.17 dB 0.22 dB 0.21 dB 0.21 dB 0.20 dB 0.16 dB 0.20 dB 0.20 dB 0.21 dB 0.19 dB 0.26 dB 0.25 dB 0.34 dB 0.26 dB 0.28 dB 0.44 dB 0.39 dB 0.23 dB 0.22 dB 0.24 dB 0.21 dB 0.22 dB 0.28 dB 0.27 dB 0.25 dB 0.24 dB 0.20 dB 0.25 dB Agilent N8975A Noise Figure Analyzer (NFA)
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3005.01) 8/21/2024 Page 8 of 11 Parameter/Range Frequency CMC2 (±) Comments Noise Figure & Excess Noise Ratio – (cont) Waveguide WR-15 WR-10 (55 to 60) GHz (60 to 64) GHz (64 to 65) GHz (75 to 80) GHz (80 to 85) GHz (85 to 90) GHz (90 to 94) GHz (94 to 100) GHz 0.44 dB 0.45 dB 0.59 dB 0.53 dB 0.82 dB 0.82 dB 0.67 dB 0.69 dB Agilent N8975A Noise Figure Analyzer (NFA) III. Mechanical Parameter/Equipment Range CMC2, 3, 5 (±) Comments Torque Wrench (20 to 200) ozf-in 1.5 % CDI torque system Pressure – Generate (0 to 15) psig (15 to 1000) psig 0.016 % of FS 0.010 % Fluke 6270A with PM500 modules IV. Thermodynamic Parameter/Equipment Range CMC2, 5 (±) Comments Temperature – Measure (-80 to 110) °C 0.010 °C Fluke SPRT, 7100 temperature bath, & super thermometer
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3005.01) 8/21/2024 Page 9 of 11 V. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Cesium Frequency Intrinsic Standard – Intrinsic Frequency Reference GPS Receiver Frequency (Frequency Offset) (5, 10) MHz 10 MHz 1.0 x 10-12 Hz/Hz (over 24 hours) 2.0 x 10 -12 Hz/Hz Agilent 5071A with high performance option 001 Symmetricom xli GPS receiver
10--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3005.01) 8/21/2024 Page 10 of 11 SATELLITE LOCATION NORTHROP GRUMMAN SYSTEMS CORPORATION, AEROSPACE SYSTEMS 3520 East Avenue M Palmdale, CA 93550 Rafael Ojeda Phone: 310 813 7404 I. Mechanical Parameter/Equipment Range CMC2, 3 (±) Comments Torque Wrench (20 to 200) ozf-in 1.5 % CDI torque system II. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Rubidium Frequency Standard – Frequency Reference 10 MHz 5.0 x 10-11 Hz/Hz Stanford research systems FS725
20 to 200 ozf-in
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3005.01) 8/21/2024 Page 11 of 11 SATELLITE LOCATION NORTHROP GRUMMAN SYSTEMS CORPORATION, AEROSPACE SYSTEMS 15333 Avenue of Science San Diego, CA 92128 Rafael Ojeda Phone: 310 813 7404 I. Mechanical Parameter/Equipment Range CMC2, 3 (±) Comments Torque Wrench (20 to 200) ozf-in 1.5 % CDI torque system II. Time & Frequency Parameter/Equipment Range CMC2, (±) Comments Rubidium Frequency Standard – Frequency Reference 10 MHz 6.0 x 10-11 Hz/Hz Stanford research systems FS725 ___________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavio r of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
12ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

One Space Park, GSEP13BA, Building S room 2049, Redondo Beach, CA, 90278, US

33.83983, -118.38459

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.