DENSO EMC Engineering Service Corporation
1-1 Showa-cho, Kariya-Shi, Aichi-ken, 448-8661, Japan, Aichi-ken, Japan
Visit website- Accredited standards
- 8
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 8 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 10605; ISO 10605 (2001, 2008, 2023); CISPR 25; CISPR 25 (2002, 2008, 2016, 2021); ISO 11452-4; ISO 11452-4 (2005, 2011, 2020); ISO 11452-2; ISO 11452-2 (2004, 2019); ISO 7637-2; ISO 7637-2 (2004, 2011); ISO 16750-2 Sections 4.6.3 and 4.6.4; ISO 16750-2 (2012) Sections 4.2, 4.3, 4.4, 4.5, 4.6.2, 4.6.3, 4.6.4, 4.7, 4.8, 4.9, 4.11, 4.12; ISO 16750-2 (2023) Sections 4.4, 4.6.3, and 4.6.4; ISO 7637-3; ISO 7637-3 (2007, 2016)
ISO 11452-4; ISO 11452-4 (2011, 2020); ISO 11452-8; ISO 11452-8 (2007, 2015); ISO 11452-9; ISO 11452-9 (2012, 2021)
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active1954.01
The scope document we hold says it was valid until 2026-09-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 1954.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 10605; ISO 10605 (2001, 2008, 2023); CISPR 25; CISPR 25 (2002, 2008, 2016, 2021); ISO 11452-4; ISO 11452-4 (2005, 2011, 2020); ISO 11452-2; ISO 11452-2 (2004, 2019); ISO 7637-2; ISO 7637-2 (2004, 2011); ISO 16750-2 Sections 4.6.3 and 4.6.4; ISO 16750-2 (2012) Sections 4.2, 4.3, 4.4, 4.5, 4.6.2, 4.6.3, 4.6.4, 4.7, 4.8, 4.9, 4.11, 4.12; ISO 16750-2 (2023) Sections 4.4, 4.6.3, and 4.6.4; ISO 7637-3; ISO 7637-3 (2007, 2016) | - | - |
| 2 | ISO 11452-4; ISO 11452-4 (2011, 2020); ISO 11452-8; ISO 11452-8 (2007, 2015); ISO 11452-9; ISO 11452-9 (2012, 2021) | Magnetic Fields | - |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
DENSO EMC ENGINEERING SERVICE CORPORATION
Aichi-ken, Japan
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 26th day of August 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 1954.01
Valid to September 30, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Japan
- UL Japan, Inc. Automotive Technology CenterMiyoshi-shi, Aichi · ~18 kmA2LAShares 1 accredited test methodISO 10605
- Denken Co., Ltd. EMC Test Lab.Kariya-shi, Aichi-ken, · ~23 kmA2LAShares 1 accredited test methodISO 10605
- LAB SupportAzumino-shi, Nagano-ken · ~157 kmA2LAShares 1 accredited test methodISO 10605
- OHTAMA CALIBRATION SERVICE Co.,Kanagawa · ~199 kmA2LAShares 1 accredited test methodISO 10605
- OKI ENGINEERING CO.,Honjo-shi, Saitama-ken · ~223 kmA2LAShares 1 accredited test methodISO 10605
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.