What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 50 standard numbers and the 29 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI17
ETSI EN 300 220-2
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrumExclusion
Limits written next to it
ETSI EN 300 328 (excluding Adaptivity)
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 386
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-7
ETSI EN 301 489-17
ETSI EN 301 489-24
ETSI EN 301 489-52
ETSI EN 301 893Exclusion
Limits written next to it
ETSI EN 301 893 (excluding Adaptivity and DFS)
ETSI EN 301 908-1
Show all 17
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI TS 134 124
ETSI TS 136 124
ETSI TS 138 124
ETSI TS 151 010-1
IEC 61000 series16
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
KS C 9610-3-2national version with changes
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
KS C 9610-3-3national version with changes
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national
National versions in the same scope
KS C 9610-4-2national version with changes
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national
National versions in the same scope
KS C 9610-4-3national version with changes
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national
National versions in the same scope
KS C 9610-4-4national version with changes
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+1 national
National versions in the same scope
KS C 9610-4-5national version with changes
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+1 national
National versions in the same scope
KS C 9610-4-6national version with changes
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test+1 national
National versions in the same scope
KS C 9610-4-8national version with changes
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+1 national
National versions in the same scope
KS C 9610-4-11probably the same standard; matched by number only
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments+1 national
National versions in the same scope
KS C 9610-6-1national version with changes
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national
National versions in the same scope
KS C 9610-6-2national version with changes
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
KS C 9610-6-3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national
National versions in the same scope
KS C 9610-6-4national version with changes
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS/NZS CISPR 11national version with changes
KS C 9811national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national
National versions in the same scope
AS/NZS CISPR 14-1national version with changes
KS C 9814-1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard+2 national
National versions in the same scope
AS/NZS CISPR 14-2probably the same standard; matched by number only
KS C 9814-2national version with changes
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national
National versions in the same scope
CNS 15936identical to it
KS C 9832national version with changes
VCCI-CISPR 32probably the same standard; matched by number only
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements+1 national
National versions in the same scope
KS C 9835national version with changes
IEC6
IEC 50270
IEC 55103-1
IEC 55103-2
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
IEC 61850-3
EN3
EN 50270
EN 55103-1
EN 55103-2
Other standards2
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
IEC 61000-4-11; EN 61000-4-11; KS C 9610-4-11; IEC 61000-4-39; EN 61000-4-39; IEEE/ANSI C63.27 2021; 47 CFR, FCC Part 15, Subpart C; ANSI C63.10:2020; ANSI C63.10; 47 CFR, FCC Part 15, Subpart E; 47 CFR, FCC Part 22; 47 CFR, FCC Part 24; 47 CFR, FCC Part 25; 47 CFR, FCC Part 27; ANSI C63.26:2015; 47 CFR, FCC Parts 22; 47 CFR, FCC Parts 90; 47 CFR, FCC Parts 95; 47 CFR, FCC Parts 97; 47 CFR, FCC Parts 101; Canada RSS-GEN; RSS-111; RSS-112; RSS-119; RSS-130; RSS-132; RSS-133; RSS-139; RSS-140; RSS-192; RSS-197; RSS-199; RSS-210; RSS-247; RSS-310; ICES-003; BETS-6; IEEE Std. 1613-2009; IEEE Std. 1613a-2011; IEEE Std. 1613.1-2013; IEC EN 61850-3:2013; ETSI EN 301 489-1; KS X 3124; ETSI EN 301 489-3; KS X 3125; ETSI EN 301 489-7; KS X 3127; ETSI EN 301 489-17; KS X 3126; ETSI EN 301 489-24; ETSI EN 301 489-52; ETSI EN 300 220-2; ETSI EN 300 330; ETSI EN 300 328; ETSI EN 301 908-1; ETSI EN 303 413; ETSI EN 301 893
GR-487-CORE; GR-950-CORE; GR-3178-CORE; GR-3108-CORE; CISPR 14-1; CISPR 14-2; IEC 55014-1; EN 55014-1; AS/NZS CISPR 14-1; KS C 9814-1; AS/NZS CISPR 14-2; EN 55014-2; KS C 9814-2; IEC 61326; EN 61326; IEC 60601-1-2 Edition 4.0 2014-02; IEC 60601-1-2 Edition 4.1 2020-09; EN 60601-1-2; AS/NZS/CISPR 24; EN 55024; KN 24; IEC 61000-6-1; EN 61000-6-1; KS C 9610-6-1; IEC 61000-6-3; EN 61000-6-3; KS C 9610-6-3; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; KS C 9835; ETSI EN 300 386; IEC 50270; EN 50270; IEC 55103-1; EN 55103-1; IEC 55103-2; EN 55103-2; CISPR 35; EN 55035
ETSI TS 134 124; 3GPP TS 34.124; ETSI TS 136 124; 3GPP TS 36.124; ETSI TS 138 124; 3GPP TS 38.124; ETSI TS 151 010-1, Section 12.2.2; 3GPP TS 51.010-1, Section 12.2.2; GR-1089-CORE, Section 2; GR-1089-CORE, Section 3; GR-1089-CORE, Section 4; GR-1089-CORE, Section 7; GR-1089-CORE, Section 8; GR-1089-CORE, Section 9; GR-1089-CORE, Section 10; GR-63-CORE, Section 2.0; GR-63-CORE, Section 4.1; GR-63-CORE, Section 4.2; GR-63-CORE, Section 4.3; GR-63-CORE, Section 4.4; GR-63-CORE, Section 4.5; GR-63-CORE, Section 4.6; GR-63-CORE, Section 4.7; GR-13-CORE (excluding Sections 3.5 Fungus Resistance and 3.5 Ozone Resistance)
47 CFR, FCC Part 15, Subpart B; ANSI C63.4:2014; 47 CFR, FCC Part 18; MP-5:1986; AS/NZS CISPR 11; EN 55011; KS C 9811; CISPR 32; CISPR 32:2015; EN 55032; EN 55032:2015; KS C 9832; AS/NZS 2297.1; VCCI V-3; CNS 15936 (2016); VCCI-CISPR 32:2016; IEC 61000-3-2; EN 61000-3-2; KS C 9610-3-2; IEC 61000-3-11; EN 61000-3-11; IEC 61000-3-3; EN 61000-3-3; KS C 9610-3-3; IEC 61000-3-12; EN 61000-3-12; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-3; EN 61000-4-3; KS C 9610-4-3; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6; IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8; ISO/IEC 17025:2017
ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2020; ANSI C63.26:2015; IEEE 1528:2013
Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-20.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active1926.01
The scope document we hold says it is valid until 2028-04-30.
Accredited scope, certificate 1926.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | 47 CFR, FCC Part 15, Subpart B; ANSI C63.4:2014; 47 CFR, FCC Part 18; MP-5:1986; AS/NZS CISPR 11; EN 55011; KS C 9811; CISPR 32; CISPR 32:2015; EN 55032; EN 55032:2015; KS C 9832; AS/NZS 2297.1; VCCI V-3; CNS 15936 (2016); VCCI-CISPR 32:2016; IEC 61000-3-2; EN 61000-3-2; KS C 9610-3-2; IEC 61000-3-11; EN 61000-3-11; IEC 61000-3-3; EN 61000-3-3; KS C 9610-3-3; IEC 61000-3-12; EN 61000-3-12; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-3; EN 61000-4-3; KS C 9610-4-3; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6; IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8; ISO/IEC 17025:2017 | - | - |
| 2 | IEC 61000-4-11; EN 61000-4-11; KS C 9610-4-11; IEC 61000-4-39; EN 61000-4-39; IEEE/ANSI C63.27 2021; 47 CFR, FCC Part 15, Subpart C; ANSI C63.10:2020; ANSI C63.10; 47 CFR, FCC Part 15, Subpart E; 47 CFR, FCC Part 22; 47 CFR, FCC Part 24; 47 CFR, FCC Part 25; 47 CFR, FCC Part 27; ANSI C63.26:2015; 47 CFR, FCC Parts 22; 47 CFR, FCC Parts 90; 47 CFR, FCC Parts 95; 47 CFR, FCC Parts 97; 47 CFR, FCC Parts 101; Canada RSS-GEN; RSS-111; RSS-112; RSS-119; RSS-130; RSS-132; RSS-133; RSS-139; RSS-140; RSS-192; RSS-197; RSS-199; RSS-210; RSS-247; RSS-310; ICES-003; BETS-6; IEEE Std. 1613-2009; IEEE Std. 1613a-2011; IEEE Std. 1613.1-2013; IEC EN 61850-3:2013; ETSI EN 301 489-1; KS X 3124; ETSI EN 301 489-3; KS X 3125; ETSI EN 301 489-7; KS X 3127; ETSI EN 301 489-17; KS X 3126; ETSI EN 301 489-24; ETSI EN 301 489-52; ETSI EN 300 220-2; ETSI EN 300 330; ETSI EN 300 328; ETSI EN 301 908-1; ETSI EN 303 413; ETSI EN 301 893 | - | to 40 GHz |
| 3 | ETSI TS 134 124; 3GPP TS 34.124; ETSI TS 136 124; 3GPP TS 36.124; ETSI TS 138 124; 3GPP TS 38.124; ETSI TS 151 010-1, Section 12.2.2; 3GPP TS 51.010-1, Section 12.2.2; GR-1089-CORE, Section 2; GR-1089-CORE, Section 3; GR-1089-CORE, Section 4; GR-1089-CORE, Section 7; GR-1089-CORE, Section 8; GR-1089-CORE, Section 9; GR-1089-CORE, Section 10; GR-63-CORE, Section 2.0; GR-63-CORE, Section 4.1; GR-63-CORE, Section 4.2; GR-63-CORE, Section 4.3; GR-63-CORE, Section 4.4; GR-63-CORE, Section 4.5; GR-63-CORE, Section 4.6; GR-63-CORE, Section 4.7; GR-13-CORE (excluding Sections 3.5 Fungus Resistance and 3.5 Ozone Resistance) | - | - |
| 4 | GR-487-CORE; GR-950-CORE; GR-3178-CORE; GR-3108-CORE; CISPR 14-1; CISPR 14-2; IEC 55014-1; EN 55014-1; AS/NZS CISPR 14-1; KS C 9814-1; AS/NZS CISPR 14-2; EN 55014-2; KS C 9814-2; IEC 61326; EN 61326; IEC 60601-1-2 Edition 4.0 2014-02; IEC 60601-1-2 Edition 4.1 2020-09; EN 60601-1-2; AS/NZS/CISPR 24; EN 55024; KN 24; IEC 61000-6-1; EN 61000-6-1; KS C 9610-6-1; IEC 61000-6-3; EN 61000-6-3; KS C 9610-6-3; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; KS C 9835; ETSI EN 300 386; IEC 50270; EN 50270; IEC 55103-1; EN 55103-1; IEC 55103-2; EN 55103-2; CISPR 35; EN 55035 | Electronic Equipment Cabinets; Optical Network Unit (ONU) Closures and ONU Systems; Wireless Transceiver Facilities; Network Equipment in the Outside Plant (OSP); Household Appliances; Laboratory Equipment; Medical Equipment; ITE/Telco Equipment; Light Industrial; Heavy Industrial; Multimedia Equipment; Telco Equipment; Gas Sensors; Professional A/V; Immunity | - |
| 5 | ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2020; ANSI C63.26:2015; IEEE 1528:2013 | - | to 40000 MHz |
| 6 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- TUV SUD AmericaAlpharetta, GA · ~442 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- Intertek Testing Services NADuluth, GA · ~451 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- Clark Dynamic Testing Laboratory, Inc.Jefferson Hills, PA · ~466 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- F2 LabsMiddlefield, OH · ~480 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- Radiometrics Midwest CorporationRomeoville, IL · ~504 kmA2LAShares 1 accredited test methodANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.