United Kingdom
Pathology Management Services
Rose Mill, Union Street, Middleton, M24 6DD, Manchester, United Kingdom
UKAS|1736ISO/IEC 17025Register collected 2026-09-11
Certificates
1
Scope items
4
Locations
1
Contact this laboratory
Work at Pathology Management Services?
Claim this profile to keep it accurate.
Register record
- UKASCollected
- 1736Active
Certificates and scope
1UKAS
ISO/IEC 17025
Active1736
Accredited scope, certificate 1736
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| Biological Testing | BS EN ISO 21528-2:2017 Enterococcus spp SOP-MB-010 using colony count technique on Slanetz and Bartley agar at 37; BS EN ISO 11290-2:2017; BS EN ISO 13720:2010 Coagulase positive Staphylococci including Staphylococcus aureus SOP-MB-006 using colony count technique at 37; BS EN ISO 6888-1:2021; BS EN ISO 7251:2005 | Food products | - |
| Biological Testing | BS EN ISO 11731:2017 using filtration of 500; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 11731:2017 using filtration of 500; IEC 17025; in-house method by | Water | - |
| Biological Testing | BS EN ISO 11290-1:2017 with confirmation using API Listeria Salmonella spp SOP-MB-016 using an enrichment technique and confirmation with API 20E based on BS EN ISO 6579- 1:2017; BS EN ISO 15213-2:2023; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 11290-1:2017 with confirmation using API Listeria Salmonella spp SOP-MB-016 using an enrichment technique and confirmation with API 20E based on BS EN ISO 6579- 1:2017; ISO 4832:2006 Clostridium perfringens SOP-MB-009 using an anaerobic colony count technique at 37 | Food products | - |
| Biological Testing | BS EN ISO 21528-2:2017 ß-glucuronidase positive Escherichia coli SOP-MB-015 based on BS ISO 16649-2:2001; BS EN ISO 11290-2:2017; BS EN ISO 6888-1:2021; ISO/IEC 17025:2017 Pathology Management Services Issue No: 039 Issue date: 31 March 2025 Rose Mill Union Street Middleton Manchester M24 6; ISO 4832:2006 | Blood | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Location
Labs with overlapping accredited scope in United Kingdom
- ALS Laboratories (UK)Rotherham · ~59 kmUKASShares 4 accredited methods and materialsISO 11290-2:2017ISO 15213-2:2023Food products
- Microsearch Laboratories LtdWest Yorkshire · ~45 kmUKASShares 3 accredited methods and materialsISO 11290-2:2017Food productsWater
- AS International Corporation Ltd trading as Alex Stewart AgricultureMerseyside · ~48 kmUKASShares 3 accredited methods and materialsISO 11290-2:2017ISO 15213-2:2023Food products
- Campden BRI (Chipping Campden)Gloucestershire · ~162 kmUKASShares 3 accredited methods and materialsISO 11290-2:2017Food productsWater
- SGS United KingdomCramlington · ~184 kmUKASShares 3 accredited methods and materialsISO 11290-2:2017ISO 15213-2:2023Food products
Accreditation data refreshed from the UKAS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.