What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 3559.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 480 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3559.01) 03/26/2024 Page 2 of 2
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Granite Accessories –
Straightness
Perpendicularity
Parallelism
Length
Up to 144 in
Up to 144 in
Up to 6 in
Up to 48 in
Up to 168 in
Up to 12 in
16 µin
30 µin
120 µin
31 µin
32 µin
(53 + 0.20L) µin
Autocollimator
Autocollimator with penta
prism on surface plate, L
in inches
Squarol & Master V block
Electronic amplifier
Autocollimator
Gage blocks
________________________________
1 This laboratory offers commercial and field calibration services and new manufactured products.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately a 95 % level of confidence, usually using a coverage
factor of k=2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of t he customer's device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the uncertainties achievable on a
customer's site can normally be expected to be larger than the CMC that the accredited laboratory has
been assigned on the A2LA Scope. Allowance must be made for aspects such as the environment at the
place of calibration and for other possible adverse effects such as those caused by transportation of the
calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated,
(e.g. resolution) must also be considered and this, on its own, could result in the calibration uncertainty
being larger than the CMC.
4 In the statement of CMC, the numerical value L is for the nominal length of the device measured in inches.
5 The CMC values listed do NOT include long- term stability of the UUT, e.g., for s urface plates the
tolerances are not included.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | to 144 in |
| 3 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- G.T. MICHELLI CO., LLC - SANTA FE SPRINGSSanta Fe Springs, CA · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Mitutoyo America CorporationCity of Industry, CA · ~13 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Element U.S. Space & DefenseFullerton, CA · ~15 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Anko ElectronicsAnaheim, CA · ~19 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- RSA Industries Inc dba American GagePlacentia, CA · ~21 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.