PCB Piezotronics of North Carolina, Inc. d.b.a. Endevco

10869 Highway 903, 27839, Halifax, NC, United States

Visit website
A2LA 1862.02ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 1862.02 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006-See scope document
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1862.02) Revised 02/25/2026 Page 2 of 4 II. Mechanical Parameter/Equipment Range CMC2, 3, 4, 5 (±) Comments Dynamic Force (Compression/Tension) – Measure (0 to 10 000) lbf 1 % full scale (FS) Reference load cell Static Pressure Up to 500 psia or psig Up to 1000 psia or psig Up to 2000 psia or psig Up to 20 000 psia or psig 0.018 % FS 0.025 % FS 0.018 % FS 0.018 % FS Pressure controller/calibrator w/built in reference Vibration General Purpose – Sensitivity Magnitude Accelerometers Low Frequency – Sensors (5 to 9) Hz (10 to 99) Hz (100 to 1999) Hz (2000 to 10 000) Hz (10 001 to 15 000) Hz (15 001 to 20 000) Hz (0.5 to 0.99) Hz (1 to 30) Hz (30.01 to 199) Hz (200 to 1000) Hz 2 % 1.5 % 1 % 2.5 % 5 % 9 % 1.8 % 1 % 1.5 % 3 % Reference accelerometer, back-to-back comparison method Reference accelerometer with long stroke shaker, back-to-back comparison method Vibration General Purpose – Acceleration Level Portable Shakers (79.6 to 159.2) Hz 1.5 % rdg Accelerometer, back-to- back comparison method
0 to 10000 lbf
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1862.02) Revised 02/25/2026 Page 3 of 4 Parameter/Equipment Range CMC2, 3, 5 (±) Comments Vibration General Purpose – Sensitivity Phase – Measure Accelerometers Low Frequency – Sensors (≥5 to <10) Hz ≥10 Hz to <5 kHz (≥5 to <11) kHz (≥11 to <16) kHz (≥16 to ≤20) kHz (≥0.5 to <10) Hz (≥10 to <200) Hz ≥200 Hz to ≤1 kHz 1° 0.75° 1.5° 2° 3° 2.5° 0.75° 1.5° Reference accelerometer, back-to-back comparison method Reference accelerometer with long stroke shaker, back-to-back comparison method Impulse Force Sensitivity (Voltage/Force) – Measure Up to 5000 lb Up to 1000 Hz 3.8 % 3.8 % Quartz reference accelerometer III. Time & Frequency Parameter/Equipment Range CMC2, 3, 5 (±) Comments Angular Rate – Measuring Equipment Up to 3000 °/s 0.3 % Acutronic AC1120S __________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentage (%) refers to percent of reading, unless otherwise noted. 4 CMCs for Vibration parameters are for Sensitivity (accelerometer/sensor) or Acceleration level (shakers).
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1862.02) Revised 02/25/2026 Page 4 of 4 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
5ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.