PCB Piezotronics of North Carolina, Inc. d.b.a. Endevco
10869 Highway 903, 27839, Halifax, NC, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 1862.02 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1862.02) Revised 02/25/2026 Page 2 of 4
II. Mechanical
Parameter/Equipment
Range
CMC2, 3, 4, 5 (±)
Comments
Dynamic Force
(Compression/Tension) –
Measure
(0 to 10 000) lbf
1 % full scale
(FS)
Reference load cell
Static Pressure
Up to 500 psia or psig
Up to 1000 psia or psig
Up to 2000 psia or psig
Up to 20 000 psia or psig
0.018 % FS
0.025 % FS
0.018 % FS
0.018 % FS
Pressure
controller/calibrator
w/built in reference
Vibration General
Purpose – Sensitivity
Magnitude
Accelerometers
Low Frequency –
Sensors
(5 to 9) Hz
(10 to 99) Hz
(100 to 1999) Hz
(2000 to 10 000) Hz
(10 001 to 15 000) Hz
(15 001 to 20 000) Hz
(0.5 to 0.99) Hz
(1 to 30) Hz
(30.01 to 199) Hz
(200 to 1000) Hz
2 %
1.5 %
1 %
2.5 %
5 %
9 %
1.8 %
1 %
1.5 %
3 %
Reference accelerometer,
back-to-back comparison
method
Reference accelerometer
with long stroke shaker,
back-to-back comparison
method
Vibration General
Purpose – Acceleration
Level
Portable Shakers
(79.6 to 159.2) Hz
1.5 % rdg
Accelerometer, back-to-
back comparison method | 0 to 10000 lbf |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1862.02) Revised 02/25/2026 Page 3 of 4
Parameter/Equipment
Range
CMC2, 3, 5 (±)
Comments
Vibration General
Purpose – Sensitivity
Phase – Measure
Accelerometers
Low Frequency –
Sensors
(≥5 to <10) Hz
≥10 Hz to <5 kHz
(≥5 to <11) kHz
(≥11 to <16) kHz
(≥16 to ≤20) kHz
(≥0.5 to <10) Hz
(≥10 to <200) Hz
≥200 Hz to ≤1 kHz
1°
0.75°
1.5°
2°
3°
2.5°
0.75°
1.5°
Reference accelerometer,
back-to-back comparison
method
Reference accelerometer
with long stroke shaker,
back-to-back comparison
method
Impulse Force Sensitivity
(Voltage/Force) –
Measure
Up to 5000 lb
Up to 1000 Hz
3.8 %
3.8 %
Quartz reference
accelerometer
III. Time & Frequency
Parameter/Equipment
Range
CMC2, 3, 5 (±)
Comments
Angular Rate –
Measuring Equipment
Up to 3000 °/s
0.3 %
Acutronic AC1120S
__________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, percentage (%) refers to percent of reading, unless otherwise noted.
4 CMCs for Vibration parameters are for Sensitivity (accelerometer/sensor) or Acceleration level (shakers). | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1862.02) Revised 02/25/2026 Page 4 of 4
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 5 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Technical Maintenance, Inc. - MORRISVILLEMorrisville, NC · ~115 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Troxler Electronic Laboratories, Inc.Research Triangle Park, NC · ~115 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- C & C TechnologiesApex, NC · ~121 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hoffer Calibration Services, LLC (a Subsidiary of Hoffer Flow Controls, Inc.)Elizabeth City, NC · ~130 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Norfolk, NCELIZABETH CITY, NC · ~130 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.