OGP Services, a Division of Quality Vision Services
1175 North Street, 14621, Rochester, NY, United States
Visit website- Accredited standards
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO 10360-2Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring machines (CMM) - Part 2: CMMs used for measuring linear dimensions
ISO 10360-5Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring systems (CMS) - Part 5: Coordinate measuring machines (CMMs) using single and multiple stylus contacting probing systems using discrete point and/or scanning measuring mode
ISO 10360-7Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring machines (CMM) - Part 7: CMMs equipped with imaging probing systems
ISO 10360-2:2009; ISO 10360-5:2020; ISO 10360-7:2011
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active1864.01
The scope document we hold says it was valid until 2026-07-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 1864.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | 5 to 200 × |
| 2 | ISO 10360-2:2009; ISO 10360-5:2020; ISO 10360-7:2011 | - | See scope document |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1864.01) Revised 4/3/2025 Page 3 of 3
Parameter/Equipment
Range
CMC2 (±)
Comments
Precision Reticles
Up to 24 in
30 µin
Grid inspection
system/SIP measuring
instrument
Z-Axis Step Gages –
Video
Step Height
Perpendicularity
(0.125 to 6) in
28 µin
36 µin
Laseruler/indi-square/
indicator
Calibration Spheres
Diameter
(0.25 to 1.0) in
28 µin
Laseruler
Step Gages – Cobra
(0.125 to 1.0) in
12 µin
Laseruler
QVS Width Gage
Up to 60 mm
0.36 μm
QVI Quest 625
________________________________
1 This laboratory offers commercial and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 Q[a, b] = √(a2 + b2 )
5 For certain types of linescales with lengths over 314 mm, the CMC claim is smaller than that of the
expanded uncertainty claim for NIST as listed in the BIPM Key Comparison Database. A2LA has
evaluated the laboratory’s CMC claim and has verified this information to be correct and appropriate.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- West Caldwell CalibrationVictor, NY · ~26 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Empire Scale Corporation d.b.a Precision Scale & BalanceLancaster, NY · ~86 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hapeman ElectronicsStoneboro, PA · ~288 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- HJM PrecisionTroy, NY · ~323 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - AllentownAllentown, PA · ~335 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.