Global Calibration Services
12870 Interurban Avenue South, 98168, Tukwila, WA, United States
Visit website- Scope lines
- 16
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 16 scope lines.
A2LA certificate 2367.01 · 16 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2367.01) 10/23/2025 Page 2 of 15
Parameter/Equipment
Range
CMC2, 4, 9 (±)
Comments
Diameter – Measure (cont)
Internal
Up to 1 in
(> 1 to 8) in
(12L + 7) µin
7L µin
Labmaster 175 & gage
blocks
Flatness – Optical Quality
Up to 2.5855 in
Diameter
6.3 µin
Optical flats
Height Gages
Up to 24 in
(0.2L + 700) µin
Gage blocks, surface
plate
Calipers –
Outer Measurement
Internal Measurement
Depth, Step
Up to 24 in
Up to 2.5 in
Up to 4 in
(20L + 200) µin
0.000 32 in
0.000 29 in
Gage blocks
Micrometers
Up to 1 in
(1 to 6) in
(6 to 20) in
(-1L + 36) µin
(7L + 120) µin
(60L + 80) µin
Gage blocks
Length Indicators –
Dial, Digital
Dial Test
Up to 1 in
(> 1 to 4) in
Up to 1 in
(> 1 to 2) in
Up to 0.060 in
Up to 0.060 in
33 μin
(9L + 80) µin
0.000 16 in
0.000 18 in
60 µin
0.000 15 in
Gage blocks
Dial indicator calibrator
Dial indicator calibrator
& gage blocks
Gage blocks
Dial indicator calibrator
Dial Indicator Calibrators
Flatness
Up to 1 in
Up to 0.3125 in
51 µin
6.3 µin
Gage blocks
Optical flats | to 1 in |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2367.01) 10/23/2025 Page 3 of 15
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Gage Head/Amplifier
(0.0001 to 0.01) in
17 µin
Gage blocks
Optical Comparators –
X Axis
Y Axis
Protractor
Screen to Table
Alignment
2 in, 4 in, 6 in
1 in, 2 in, 3 in
90°, 180°, 270°, 360°
X & Y
0.000 13 in
0.000 13 in
0.02°
0.01°
Magnification checker
0.1875 in sphere
Thread Plug –
Pitch Diameter
Major Diameter
(0.06 to 1.625) in
(0.06 to 1.625) in
(2.4L + 97) µin
(11L + 47) µin
Thread wires, gage
blocks, &
Supermicrometer
TM
(UMM)
Gage blocks &
SupermicrometerTM
(UMM)
V Blocks –
V Central
V Parallel
Up to (2 ¼ x 2 ¼ x 3) in
58 µin
86 µin
Plain plug gage,
electronic gaging amp
granite surface plate,
gaging amp, plain plug
gage
Precision Levels –
Concavity
Left-Right Reading
0.0005 in/ft
17L µin
6.1L µin
Electronic gaging amp,
granite surface plate,
gage blocks
Supermicrometers
Linearity to 1 in
(0.08L + 25) µin
Gage blocks
Gage Block Comparator –
Measuring Range
Calibration Constant
(0.1001 to 0.1005) in
1 in
4.2 µin
0.000 58 in
Grade 00 gage blocks
Grade 00 gage blocks | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2367.01) 10/23/2025 Page 4 of 15
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Federal Leveling
System
(-900 to 990) arc sec
9.8 arc sec
Gage blocks, sine
plate, surface plate
Surface Plates –
Flatness
Up to (48 x 72) in
(1.1D + 8.6) μin
Federal leveling
system
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 5, 6, 7 (±)
Comments
DC Voltage3 –
Generate
(0 to 330) mV
(0 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1000) V
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 22) V
(22 to 220) V
1000 V
55 µV/V + 1.2 µV
20 µV/V + 2.4 µV
21 µV/V + 24 µV
24 µV/V + 180 µV
29 µV/V + 1.8 mV
14 µV/V + 0.4 µV
7 µV/V + 0.7 µV
5 µV/V + 2.5 µV
7 µV/V + 40 µV
8 µV/V + 400 µV
Fluke 5520A/SC1100
Fluke 5720A
DC Voltage3 –
Measure
(0 to 100) mV
100.1 mV to 1 V
(1.1 to 10) V
(10.1 to 100) V
(100.1 to 1000) V
(1 to 5) kV
26 µV/V + 0.3 µV
12 µV/V + 0.3 µV
9.3 µV/V + 0.5 µV
12 µV/V + 30 µV
15 µV/V + 0.1 mV
3.6 VDC
HP 3458A
Fluke 80E-10
DC Current3 –
Generate
330 µA to 3.3 mA
(3.3 to 33) mA
(33 to 330) mA
330 mA to 1.1 A
(1.1 to 3) A
(3 to 11) A
Up to 220 µA
(0.22 to 2) mA
(2 to 20) mA
0.02 % + 0.024 µA
0.02 % + 0.024 µA
0.02 % + 0.024 µA
0.04 % + 47 µA
0.06 % + 47 µA
0.14 % + 580 µA
84 µA/A + 6 nA
80 µA/A + 7 nA
65 µA/A + 40 nA
Fluke 5520A/SC1100
multifunction
calibrator
Fluke 5720A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2367.01) 10/23/2025 Page 5 of 15
Parameter/Equipment
Range
CMC2, 5, 6, 7 (±)
Comments
DC Current3 – Generate
(cont)
(20 to 200) mA
(0.2 to 1) A
73 µA/A + 0.7 nA
0.012 % + 12 µA
Fluke 5720A
DC Current3 – Measure
Up to 100 µA
100.1 µA to 1 mA
(1.1 to 10) mA
(10.1 to 100) mA
100.1 mA to 1 A
0.04 mA/A + 0.8 nA
0.07 mA/A + 5 nA
0.03 mA/A + 50 nA
0.05 mA/A + 0.5 µA
0.14 mA/A + 10 µA
HP 3458A multimeter
DC Current Shunt3
1 A Applied
5 A Applied
10 A Applied
15 A Applied
1.0 mΩ
9.3 mΩ
16 mΩ
23 mΩ
HP 3458A multimeter
Fluke 5520A
Resistance3 – Generate
Fixed Points
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
330 Ω to 1.1 kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
330 kΩ to 1.1 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
0.02 % + 0.0012 Ω
0.01 % + 0.0017 Ω
0.01 % + 0.0016 Ω
34 µΩ/Ω + 0.0023 Ω
40 µΩ/Ω + 0.0023 Ω
0.01 % + 0.024 Ω
41 µΩ/Ω + 0.024 Ω
0.01 % + 0.24 Ω
41 µΩ/Ω + 0.24 Ω
0.01 % + 2.6 Ω
47 µΩ/Ω + 3 Ω
0.01 % + 37 Ω
0.02 % + 64 Ω
0.05 % + 3 kΩ
0.07 % + 3.6 kΩ
0.012 %
0.012 %
29 µΩ/Ω
31 µΩ/Ω
13 µΩ/Ω
14 µΩ/Ω
12 µΩ/Ω
10 µΩ/Ω
11 µΩ/Ω
10 µΩ/Ω
13 µΩ/Ω
13 µΩ/Ω
24 µΩ/Ω
25 µΩ/Ω
Fluke 5520A/SC1100
Fluke 5720A | ||
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2367.01) 10/23/2025 Page 6 of 15
Parameter/Equipment
Range
CMC2, 5, 6, 7 (±)
Comments
Resistance3 – Generate
(cont)
Fixed Points
10 MΩ
19 MΩ
100 MΩ
47 µΩ/Ω
56 µΩ/Ω
0.013 %
Fluke 5720A
Resistance3 – Measure
Up to 10 Ω
(10.1 to 100) Ω
100.1 Ω to 1 kΩ
(1.1 to 10) kΩ
(10.1 to 100) kΩ
100.1 kΩ to 1 MΩ
(1.1 to 10) MΩ
(10.1 to 100) MΩ
31 µΩ/Ω + 50 µΩ
22 µΩ/Ω + 0.05 mΩ
14 µΩ /Ω + 0.5 mΩ
14 µΩ /Ω + 5 mΩ
16 µΩ /Ω + 50 mΩ
27 µΩ /Ω + 20 Ω
78 µΩ /Ω + 0.1 kΩ
600 µΩ /Ω + 1 kΩ
HP 3458A
Parameter/Range
Frequency
CMC2, 5, 7 (±)
Comments
Capacitance3 – Generate
(0.19 to 0.4) nF
(0.4 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
330 nF to 1.1 µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
Up to 50 Hz
4.5 % + 0.012 nF
3.4 % + 0.012 nF
1.4 % + 0.012 nF
0.57 % + 0.012 nF
1 % + 0.12 nF
0.47 % + 0.12 nF
0.54 % + 0.35 nF
0.47 % + 1.2 nF
0.54 % + 3.5 nF
0.6 % + 12 nF
0.74 % + 35 nF
0.87 % + 120 nF
0.82 % + 350 nF
Fluke 5520A/SC1100
multifunction
calibrator
Frequencies identified
in the Frequency
column refer to the
allowable frequency or
discharge rate. | to 100000000 Ω |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2367.01) 10/23/2025 Page 7 of 15
Parameter/Range
Frequency
CMC2, 5, 7 (±)
Comments
AC Voltage3 – Generate
(1 to 33) mV
(33 to 330) mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
2.2 mV
22 mV
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
0.13 % + 7 µV
0.05 % + 7 µV
0.05 % + 7 µV
0.16 % + 7 µV
0.52 % + 14 µV
1.3 % + 58 µV
0.05 % + 9.3 µV
0.03 % + 9.3 µV
0.03 % + 9.3 µV
0.06 % + 9.3 µV
0.14 % + 37 µV
0.33 % + 81 µV
0.04 % + 9.3 µV
0.03 % + 9.3 µV
0.03 % + 9.3 µV
0.05 % + 9.3 µV
0.11 % + 37 µV
0.37 % + 81 µV
0.04 % + 760 µV
0.02 % + 700 µV
0.04 % + 700 µV
0.05 % + 700 µV
0.13 % + 2.4 mV
0.03 % + 2.4 mV
0.04 % + 7 mV
0.04 % + 7 mV
0.05 % + 7 mV
0.32 % + 59 mV
0.04 % + 12 mV
0.04 % + 12 mV
0.04 % + 12 mV
1.3 % + 4 µV
3.9 % + 4 µV
1.1 % + 5 µV
0.05 % + 4 µV
0.09 % + 4 µV
0.15 % + 5 µV
0.19 % + 10 µV
0.3 % + 20 µV
Fluke 5520A/SC1100
Fluke 5720A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2367.01) 10/23/2025 Page 8 of 15
Parameter/Range
Frequency
CMC2, 5, 6, 7 (±)
Comments
AC Voltage3 – Generate
(cont)
200 mV
2.2 V
22 V
220 V
1100 V
(10 to 20) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(15 to 50) Hz
50 Hz to 1 kHz
0.042 % + 12 µV
0.018 % + 7 µV
0.032 % + 7 µV
0.1 % + 17 µV
0.13 % + 20 µV
0.2 % + 25 µV
31 µV/V + 40 µV
0.013 % + 15 µV
74 µV/V + 8 µV
0.012 % + 10 µV
0.019 % + 30 µV
0.07 % + 80 µV
0.15 % + 200 µV
0.034 % + 400 µV
0.013 % + 150 µV
0.007 % + 50 µV
0.012 % + 100 µV
0.017 % + 200 µV
0.05 % + 600 µV
0.15 % + 2 V
0.034 % + 4 mV
0.013 % + 1.5 mV
78 µV/V + 0.6 mV
0.014 % + 1 mV
0.023 % + 2.5 mV
0.04 % + 16 mV
95 µV/V + 3.5 mV
Fluke 5720A
AC Voltage3 – Measure
Up to 10 mV
(1 to 40) Hz
40.1 Hz to 1 kHz
(1.1 to 20) kHz
(20.1 to 50) kHz
(50.1 to 100) kHz
(100.1 to 300) kHz
0.048 % + 3 µV
0.046 % + 1.1 µV
0.055 % + 1.1 µV
0.59 % + 1.1 µV
0.59 % + 1.1 µV
4.6 % + 2 µV
HP 3458A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2367.01) 10/23/2025 Page 9 of 15
Parameter/Range
Frequency
CMC2, 5, 6, 7 (±)
Comments
AC Voltage3 – Measure
(cont)
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 700) V
(1 to 40) Hz
40.1 Hz to 1 kHz
(1.1 to 20) kHz
(20.1 to 50) kHz
(50.1 to 100) kHz
(100.1 to 300) kHz
(1 to 40) Hz
40.1 Hz to 1 kHz
(1.1 to 20) kHz
(20.1 to 50) kHz
(50.1 to 100) kHz
(100.1 to 300) kHz
(300 to 500) kHz
(1 to 40) Hz
40.1 Hz to 1 kHz
(1.1 to 20) kHz
(20.1 to 50) kHz
(50.1 to 100) kHz
(100.1 to 300) kHz
(300 to 500) kHz
(1 to 40) Hz
40.1 Hz to 1 kHz
(1.1 to 20) kHz
(20.1 to 50) kHz
(50.1 to 100) kHz
1 Hz to 1 kHz
0.011 % + 4 µV
0.011 % + 2 µV
0.019 % + 2 µV
0.095 % + 2 µV
0.095 % + 2 µV
0.36 % + 10 µV
0.026 % + 40 µV
0.011 % + 20 µV
0.019 % + 20 µV
0.037 % + 20 µV
0.097 % + 20 µV
0.36 % + 0.1 mV
1.2 % + 0.1 mV
0.011 % + 0.4 mV
0.011 % + 0.2 mV
0.019 % + 0.2 mV
0.037 % + 0.2 mV
0.095 % + 0.2 mV
0.36 % + 1 mV
1.2 % + 1 mV
0.026 % + 4 mV
0.026 % + 2 mV
0.026 % + 2 mV
0.043 % + 2 mV
0.14 % + 2 mV
0.05 % + 0.02 V
HP 3458A
AC Current3 – Generate
(29 to 330) µA
330 µA to 3.3 mA
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.31 % + 0.12 µA
0.21 % + 0.12 µA
0.47 % + 0.17 µA
1.2 % + 0.23 µA
2.4 % + 0.46 µA
0.27 % + 0.17 µA
0.28 % + 0.23 µA
0.68 % + 21 µA
1.4 % + 0.69 µA
1.4 % + 0.69 µA
Fluke 5520A/SC110 | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2367.01) 10/23/2025 Page 10 of 15
Parameter/Range
Frequency
CMC2, 5, 7 (±)
Comments
AC Current3 – Generate
(cont)
(3.3 to 33) mA
(33 to 330) mA
330 mA to 1.1 A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(22 to 220) µA
(0.22 to 2.2) mA
(2.3 to 22) mA
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
40 Hz
1 kHz
5 kHz
40 Hz
1 kHz
5 kHz
40 Hz
1 kHz
5 kHz
0.25 % + 2.4 µA
0.12 % + 2.4 µA
0.28 % + 3.5 µA
0.55 % + 4.7 µA
0.55 % + 4.7 µA
0.25 % + 24 µA
0.19 % + 58 µA
0.31 % + 120 µA
0.62 % + 240 µA
0.62 % + 240 µA
0.25 % + 120 µA
0.21 % + 1200 µA
4 % + 5.8 mA
4 % + 5.8 mA
0.25 % + 120 µA
0.85 % + 1.2 mA
3.6 % + 5.8 mA
3.6 % + 5.8 mA
0.17 % + 2.4 mA
4.1 % + 2.4 mA
4.1 % + 2.4 mA
0.25 % + 5.8 mA
0.29 % + 5.8 mA
4.1 % + 5.8 mA
0.026 % + 8 nA
0.048 % + 12 nA
0.21 % + 65 nA
99 µA/A + 35 nA
0.037 % + 110 nA
0.21 % + 650 nA
0.017 % + 350 nA
0.017 % + 350 nA
0.03 % + 550 nA
Fluke 5520A/SC110
Fluke 5720A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2367.01) 10/23/2025 Page 11 of 15
Parameter/Range
Frequency
CMC2, 5, 6, 7 (±)
Comments
AC Current3 – Generate
(cont)
(22.1 to 220) mA
(0.22 to 1) A
(1 to 1.5) A
40 Hz
1 kHz
5 kHz
40 Hz
1 kHz
5 kHz
40 Hz
1 kHz
5 kHz
0.017 % + 3.5 nA
0.017 % + 2.5 nA
0.028 % + 3.5 nA
0.037 % + 35 µA
0.063 % + 80 µA
0.063 % + 80 µA
0.034 % + 35 µA
0.059 % + 80 µA
0.059 % + 80 µA
Fluke 5720A
AC Current3 – Measure
Up to 100 µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(10 to 20) Hz
(20.1 to 45) Hz
(45.1 to 100) Hz
100.1 Hz to 1 kHz
(10 to 20) Hz
(20.1 to 45) Hz
(45.1 to 100) Hz
100.1 Hz to 5 kHz
(5.1 to 20) kHz
(10 to 20) Hz
(20.1 to 45) Hz
(45.1 to 100) Hz
100.1 Hz to 5 kHz
(5.1 to 20) kHz
(10 to 20) Hz
(20.1 to 45) Hz
(45.1 to 100) Hz
100.1 Hz to 5 kHz
(10 to 20) Hz
(20.1 to 45) Hz
(45.1 to 100) Hz
100.1 Hz to 5 kHz
0.5 % + 0.03 µA
0.21 % + 0.03 µA
0.11 % + 0.03 µA
0.11 % + 0.03 µA
0.49 % + 0.2 µA
0.2 % + 0.2 µA
0.09 % + 0.2 µA
0.06 % + 0.2 µA
0.07 % + 0.2 µA
0.49 % + 2 µA
0.2 % + 2 µA
0.09 % + 2 µA
0.06 % + 2 µA
0.09 % + 2 µA
0.49 % + 20 µA
0.2 % + 20 µA
0.09 % + 20 µA
0.06 % + 20 µA
0.49 % + 0.2 mA
0.21 % + 0.2 mA
0.12 % + 0.2 mA
0.14 % + 0.2 mA
HP 3458A | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2367.01) 10/23/2025 Page 12 of 15
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouples Generate
& Measure3–
Type E
Type J
Type K
Type R
Type S
Type T
(-250 to -100) °C
(-99.9 to -25) °C
(-24.9 to 350) °C
(350.1 to 650) °C
(650.1 to 1000) °C
(-210 to -100) °C
(-99.9 to -30) °C
(-29.9 to 150) °C
(150.1 to 760) °C
(760.1 to 1200) °C
(-200 to -100) °C
(-99.9 to -25) °C
(-24.9 to 120) °C
(120.1 to 1000) °C
(1000.1 to 1372) °C
(0 to 250) °C
(250.1 to 400) °C
(400.1 to 1000) °C
(1000.1 to 1767) °C
(0 to 250) °C
(250.1 to 1000) °C
(1000.1 to 1400) °C
(1400.1 to 1767) °C
(-250 to -150) °C
(-149.9 to 0) °C
(0.1 to 120) °C
(120.1 to 400) °C
0.59 °C
0.21 °C
0.18 °C
0.20 °C
0.25 °C
0.32 °C
0.23 °C
0.21 °C
0.21 °C
0.28 °C
0.39 °C
0.22 °C
0.20 °C
0.22 °C
0.47 °C
0.67 °C
0.41 °C
0.41 °C
0.48 °C
0.57 °C
0.48 °C
0.45 °C
0.56 °C
0.74 °C
0.29 °C
0.20 °C
0.18 °C
Fluke 5520A/SC1100
III. Mechanical
Parameter/Equipment
Range
CMC2, 7, 9 (±)
Comments
Force – Measuring
Equipment
Up to 50 lbf
(50.1 to 200) lbf
(0.004 % + 0.043) lbf
(0.07 % + 0.064) lbf
Weights | ||
| 13 | OIML Class E2; NIST Class F | - | See scope document |
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2367.01) 10/23/2025 Page 14 of 15
IV. Thermodynamics
Parameter/Equipment
Range
CMC2, 4, 9 (±)
Comments
Temperature3 – Measure
(20 to 70) °C
(-40 to 0) °C
(1 to 150) °C
0.0036T + 0.19 °C
-0.020T + 0.90 °C
0.01T + 1.1 °C
Vaisala MI70/HMP76
Omega digital
temperature calibrator
Temperature3 –
Measuring Equipment
(0 to 100) °C
(-0.0002T + 0.70) °C
Omega digital
temperature calibrator,
monitoring Hart
Scientific 7102 micro-
bath
Micro-Bath
(0 to 100) °C
(0.008T + 0.40) °C
Omega digital
temperature calibrator
Relative Humidity3 –
Measuring Equipment
(22.2 to 90.1) % RH
(0.017H + 1.2) % RH
Vaisala MI70/HMP76
with sealed chamber
Relative Humidity3 –
Measure
(35 to 75) % RH
(0.015H + 2.1) % RH
Vaisala MI70/HMP76
_______________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the length of the unit under test in inches, D is the diagonal length of the
unit under test in inches, and T is the temperature in °C. | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2367.01) 10/23/2025 Page 15 of 15
5 The measurands stated are generated with the Fluke 5520A and 5720A series of instruments. This
capability is suitable for the calibration of the devices intended to measure the stated measurand in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction
of the reading plus a fixed floor specification.
6 The measurands stated are measured with the HP 3458A. This capability is suitable for the calibration of
the devices intended to generate the measurand in the ranges indicated. CMCs are expressed as either a
specific value that covers the full range or as a combination of the fraction of the reading/output plus a
range specification.
7 In the statement of CMC, the value is defined as the percentage of reading unless otherwise noted.
8 This scope meets A2LA’s P112 Flexible Scope Policy.
9 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 16 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- ThermetricsSeattle, WA · ~17 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - SeattleRedmond, WA · ~25 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Cascade Engineering ServicesRedmond, WA · ~26 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Eustis Co., Inc./Pyrocom CalibrationLynnwood, WA · ~41 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Robb Precision Tool ServicesLynnwood, WA · ~41 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994