Fluke Corporation - Everett Service Center
1420 75th Street SW, 98203, Everett, WA, United States
Visit website- Scope lines
- 80
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 80 scope lines.
A2LA certificate 2166.01 · 80 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 2 of 79
(Table 2 of 3)
DC Voltage
Parameter/Equipment
Range
(±) CMC2, 4, 5, 13
Comments
DC Voltage
Measure
0.00 V 0.15 µV Copper short
± (0 to 10) mV
± (10 to 120) mV
9.0 µV/V + 0.21 µV
3.0 µV/V + 0.10 µV HP 3458A characterized
DMM
Utilized in 57XX &
55XX calibrations
± 120 mV to ± 1.2 V 0.70 µV/V + 0.20 µV
± (1.2 to 12) V 0.50 µV/V + 0.50 µV
± (12 to 120) V 0.8 µV/V + 20 µV
± 120 V to ± 1.05 kV 1.9 µV/V + 0.15 mV
(1.0 to 40) kV 0.10 %
Direct measurements
using Ross VD120
voltage divider/Fluke
8846A
For calibration of
5320A & 80K high
voltage probes
DC Voltage
Generate
± (0 to 10) mV
± (10 to 220) mV
9.0 µV/V + 0.21 µV
3.0 µV/V + 0.30 µV
Characterization of
Fluke 5720/5725A w/
732, 752, & 845
for DC voltage sourcing
applications
± 220 mV to ± 2.2 V 1.0 µV/V + 1.0 µV
± (2.2 to 11) V 0.60 µV/V + 2.5 µV
± (11 to 22) V 0.60 µV/V + 5.0 µV
± (22 to 220) V 1.0 µV/V + 50 µV
± 220 V to ± 1.1 kV 1.2 µV/V + 0.20 mV
± (1.1 to 1.5) kV 16 µV/V + 1.8 mV
Two 5520A/5522As
with one sourcing
positive voltage, one
sourcing negative, &
OUT LO terminals
connected. | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 3 of 79
(Table 3 of 3)
DC Voltage
Parameter/Equipment
Range
(±) CMC2, 4, 13
Comments
DC Voltage
Generate
(Fixed Points)
± 10 mV 280 µV/V
Calibration of 8588A
characterized station
using 5720A/5725A
± 100 mV 4.4 µV/V
± 200 mV 4.6 µV/V
± 1 V 0.97 µV/V
± 1.5 V 4.8 µV/V
± 2 V 0.97 µV/V
± 5 V 1.4 µV/V
± 10 V 0.73 µV/V
± 15 V 1.1 µV/V
± 20 V 1.3 µV/V
± 100 V 1.7 µV/V
± 200 V 1.7 µV/V
± 500 V 2.0 µV/V
± 1 kV 2.0 µV/V
DC Reference
Measure & Generate
(Fixed Points)
± 0.200 V reference 0.40 µV/V Direct transfer
techniques performed
utilizing two Fluke
732C in series
For 8588A station
transfer calibrations
± 2.00 V reference 0.30 µV/V
± 20.0 V reference 0.30 µV/V | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 4 of 79
(Table 1 of 3)
DC Current
Parameter/Equipment
Range
(±) CMC2, 4, 13
Comments
DC Current
Measure
± 100 µA 3.0 µA/A Characterization of
Fluke 5720/5725A w/
comparison to DC
reference shunts &
characterized
voltmeter, for
calibration of long
scale DMMS
Char A40B shunt
± 1 mA 3.0 µA/A
± 10 mA 3.0 µA/A
± 100 mA 5.0 µA/A
± 1 A 10 µA/A
± 10 A
± 30 A
30 µA/A
29 µA/A
DC Current
Generate6
± 100 µA 5.0 µA/A Calibration of
reference multimeter
w/ Fluke 5720/5725A
characterized
calibrator
Char Fluke 52120
± 1 mA 4.7 µA/A
± 10 mA 3.0 µA/A
± 100 mA 8.0 µA/A
± 1 A 10 µA/A
± 10 A
± 30 A
100 µA/A
65 µA/A
DC Current
Generate Using a
Transconductance
Amplifier
± (3.3 to 20) A 78 µA/A + 37 mA
Calibration of clamp
meters using a 5522A
driving a 52120A
into a single wire
± (20.000 01 to 32.999 99) A 79 µA/A + 38 mA
± (33 to 40) A 78 µA/A + 38 mA
± (40.0001 to 120) A 78 µA/A + 110 mA | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 5 of 79
(Table 2 of 3)
DC Current
Parameter/Equi
pment
Range
(±) CMC2, 4, 13
Comments
DC Current
Generate Using a
Coil
± (10 to 16.499 95) A 0.39 % + 40 mA Calibration of
Fluke 39X-series
clamps using
Fluke 5522A &
Fluke
5500A/COIL
± (16.5 to 80) A 0.39 % + 110 mA
± (80.0005 to 149.9995) A 0.39 % + 180 mA
± (150 to 549.995) A 0.39 % + 410 mA
± (550 to 1025) A 0.40 % + 530 mA
DC Current
Generate Using a
Coil &
Transconductanc
e Amplifier
± (10 to 40) A 0.54 % + 130 mA
Calibration of
Fluke 35X-series
clamps
using Fluke
5522A with
52120A &
52120A/COIL3K
A
± (40.00025 to 50) A 0.54 % + 140 mA
± (50.000 25 to 500) A 0.54 % + 180 mA
± (500.0025 to 999.9975) A 0.54 % + 670 mA
± (1000 to 2000) A 0.54 % + 880 mA
DC Current
Measure &
Generate
0.00 A 0.000 060 µA Open input
± (1 to 10) µA 6.0 µA/A + 10 pA
Standard reference
resistors, shunts &
an 8.5-digit DMM
calibration of
52120A, 55XX &
57XX
± (10 to 100) µA 6.0 µA/A + 60 pA
± 100 µA to 1 mA 6.0 µA/A + 1.0 nA
± (1 to 10) mA 6.0 µA/A + 10 nA
± (10 to 100) mA 6.0 µA/A + 0.10 µA
± 100 mA to ± 1 A 6.0 µA/A + 1.8 µA
± (1 to 10) A 5.0 µA/A + 5.0 µA
± (10 to 20) A 55 µA/A + 20 µA
DC Current
Measure ± (80 to 120) A 35 µA/A
Fluke 52120A
transconductance
amplifier
calibration | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 6 of 79
(Table 3 of 3)
DC Current
Parameter/Equipment
Range
(±) CMC2, 4, 13
Comments
DC Current
Generate
± 10.0 µA 29 µA/A
Calibration of 8588A
characterized station
using 5720A/5725A
± 10.0 µA 25 µA/A
± 100.0 µA 7.7 µA/A
± 200.0 µA 7.0 µA/A
± 1 mA 5.8 µA/A
± 2 mA
± 10 mA
5.8 µA/A
5.4 µA/A
± 20 mA 5.4 µA/A
± 100 mA 13 µA/A
± 200 mA 13 µA/A
± 1 A 25 µA/A
± 2 A 39 µA/A
± 10 A
± 30 A
45 µA/A
78
µA/A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 7 of 79
(Table 1 of 3)
Resistance
Parameter/Equipment
Range
(±) CMC2, 4, 5, 13
Comments
Resistance
Measure
0.00 Ω 2.5 µ Ω Copper short
100 GΩ 0.040 % Ohms lab reference
resistors
5320 calibration station
characterization
1 TΩ 0.040 %
10 TΩ 0.090 %
(Table 2 of 3)
Resistance
Parameter/Equipment
Range
(±) CMC2, 4, 5, 13
Comments
Resistance
Measure & Generate
(0.0001 to 0.01) Ω 6.0 µΩ Calibration of standard
resistors with
Measurements
International 6010
bridge
For Fluke 742 standard
resistance calibrations
& long scale meter
calibration station
characterization
(0.01 to 0.1) Ω 5.0 μΩ/Ω
(0.1 to 1) Ω 1.0 μΩ/Ω
(1 to 10) Ω 0.50 μΩ/Ω
(10 to 100) Ω 0.50 μΩ/Ω
100 Ω to 1 kΩ 0.50 μΩ/Ω
(1 to 10) kΩ 0.70 μΩ/Ω
(10 to 100) kΩ 0.70 μΩ/Ω
100 kΩ to 1 MΩ 1.6 μΩ/Ω
(1 to 10) MΩ 2.2 μΩ/Ω
(10 to 100) MΩ 5.1 μΩ/Ω
100 MΩ to 1.1 GΩ 26 μΩ/Ω
10 GΩ 0.028 % Fluke 8508A calibration
Resistance
Generate
2 GΩ 0.15 %
Calibration of Fluke
5320A using QuadTech
1865 megohmmeter &
reference resistors
4 GΩ 0.15 %
8 GΩ 0.15 %
10 GΩ 0.15 %
100 GΩ 0.20 %
1 TΩ 0.50 %
9 TΩ 0.90 % | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 8 of 79
(Table 3 of 3)
Resistance
Parameter/Equipment
Range
(±) CMC2, 4, 13
Comments
Resistance
Measure & Generate
1 Ω 4.6 μΩ/Ω
Calibration of 8588A
characterized station
using 5720A/5725A
1.9 Ω 6.3 μΩ/Ω
10.0 Ω 3.1 μΩ/Ω
19.0 Ω 3.0 μΩ/Ω
100.0 Ω 2.0 μΩ/Ω
190.0 Ω 2.2 μΩ/Ω
1.0 kΩ 1.7 μΩ/Ω
1.9 kΩ 1.7 μΩ/Ω
10 kΩ 2.5 μΩ/Ω
19 kΩ 2.4 μΩ/Ω
100 kΩ 2.9 μΩ/Ω
190 kΩ 2.8 μΩ/Ω
1 MΩ 4.8 μΩ/Ω
1.9 MΩ 4.6 μΩ/Ω
10 MΩ 6.8 μΩ/Ω
19 MΩ 7.8 μΩ/Ω
100 MΩ 34 μΩ/Ω
1.0 GΩ 82 μΩ/Ω
10 GΩ 240 μΩ/Ω | ||
| 9 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 9 of 79
(Table 1 of 2)
AC Voltage Phase Measure (Ranges)
Frequency AC Voltage (±) CMC2, 4, 13
0.25 V 1.5 V 2.4 V 10 V 23 V 45 V
16 Hz 0.8 1.0 0.7 1.4 1.4 1.4
40 Hz 1.8 1.9 0.7 2.2 2.1 2.1
50 Hz 2.3 2.3 0.8 2.6 2.5 2.5
60 Hz 2.7 2.8 1.1 3.0 2.9 2.9
120 Hz 5.4 5.4 1.3 5.7 5.7 5.7
180 Hz 8.0 8.2 2.1 8.3 8.2 8.2
450 Hz 20 20 3.6 21 21 21
850 Hz 38 38 6.4 39 38 38
1.2 kHz 54 54 9.2 55 54 54
1.8 kHz 80 80 14 82 81 81
2.4 kHz 110 110 18 110 110 110
3 kHz 140 140 22 140 140 140
3.6 kHz 160 160 26 170 170 170
4.2 kHz 190 190 31 190 190 190
4.8 kHz 220 220 35 220 220 220
5.4 kHz 240 240 40 250 250 250
6 kHz 270 270 44 270 270 270
Comments
Uncertainty applies from (10 to 100) % of range & are in m˚.
These uncertainties apply when measuring the phase of the Fluke 61XXA voltage
channel output with respect to the ''master phase reference” signal at the rear of the
instrument.
The 2.4 V range is only accessible to drive the Fluke 52120A transconductance
amplifier, the uncertainties for this range assume a combined Fluke 61XXA & Fluke
52120A calibration system using the same Hewlett Packard 3458A. | 10 to 100 % |
| 10 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 10 of 79
(Table 2 of 2)
AC Voltage Phase Measure (Ranges)
Frequency
AC Voltage (±) CMC2, 4, 13
90 V Range Linearity
7 V 90 V 180 V 360 V 1008 V
16 Hz 3.4 1.4 1.4 1.4 1.5
40 Hz 3.7 2.1 2.1 2.2 2.2
50 Hz 3.9 2.5 2.5 2.6 2.6
60 Hz 4.2 2.9 2.9 3.0 3.0
120 Hz 6.3 5.7 5.7 5.7 5.7
180 Hz 8.7 8.2 8.2 8.3 8.3
450 Hz 21 21 21 21 21
850 Hz 39 38 38 39 39
1.2 kHz 54 54 54 55 54
1.8 kHz 81 81 81 81 81
2.4 kHz 110 110 110 110 110
3 kHz 140 140 140 140 140
3.6 kHz 170 170 170 170 170
4.2 kHz 190 190 190 190 190
4.8 kHz 220 220 220 220 220
5.4 kHz 250 250 250 250 250
6 kHz 270 270 270 270 270
Comments
Uncertainty applies from (10 to 100) % of range & are in m˚
These uncertainties apply when measuring the phase of the Fluke 61XXA voltage
channel output with respect to the ''master phase reference” signal at the rear of the
instrument.
The 2.4 V range is only accessible to drive the Fluke 52120A Transconductance
Amplifier, the uncertainties for this range assume a combined Fluke 61XXA & Fluke
52120A calibration system using the same Hewlett Packard 3458A | 10 to 100 % |
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 11 of 79
(Table 1 of 2)
AC Current Phase Measure (Ranges)
Frequency AC Current (±) CMC2, 4, 13
0.1 A 0.5 A 1 A 2 A 5 A
16 Hz 1.0 1.0 1.0 1.0 1.0
40 Hz 1.9 1.9 1.9 1.9 1.9
50 Hz 2.4 2.4 2.4 2.4 2.4
60 Hz 2.8 2.8 2.8 2.8 2.8
120 Hz 5.4 5.4 5.4 5.4 5.4
180 Hz 8.1 8.1 8.0 8.0 8.1
450 Hz 20 20 20 20 20
850 Hz 38 38 38 38 38
1.2 kHz 54 54 54 54 54
1.8 kHz 80 80 80 80 80
2.4 kHz 110 110 110 110 110
3 kHz 140 140 140 140 140
3.6 kHz 160 160 160 160 160
4.2 kHz 190 190 190 190 190
4.8 kHz 220 220 220 220 220
5.4 kHz 240 240 240 240 240
6 kHz 270 270 270 270 270
Comments
Uncertainty applies from (10 to 100) % of range & are in m˚
These uncertainties apply when measuring the phase of the Fluke 61XXA voltage
channel output with respect to the ''master phase reference” signal at the rear of the
instrument | 10 to 100 % |
| 12 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 12 of 79
(Table 2 of 2)
AC Current Phase Measure (Ranges)
Frequency
AC Current (±) CMC2, 4, 13
10 A Range Linearity
0.5 A 10 A 20 A 50 A 100 A
16 Hz 3.6 1.0 1.0 1.0 1.0
40 Hz 3.9 1.9 1.9 1.9 1.9
50 Hz 4.1 2.4 2.4 2.4 2.4
60 Hz 4.3 2.8 2.8 2.8 2.8
120 Hz 6.9 5.4 5.4 5.4 5.4
180 Hz 9.2 8.1 8.1 8.1 8.1
450 Hz 21 20 21 21 21
850 Hz 38 38 38 38 38
1.2 kHz 54 54 54 54 54
1.8 kHz 81 80 81 81 81
2.4 kHz 110 110 110 110 110
3 kHz 140 140 140 140 140
3.6 kHz 160 160 170 170 170
4.2 kHz 190 190 190 190 190
4.8 kHz 220 220 220 220 220
5.4 kHz 240 240 250 250 250
6 kHz 270 270 270 270 270
Comments
Uncertainty applies from (10 to 100) % of range & are in m˚
These uncertainties apply when measuring the phase of the Fluke 61XXA voltage
channel output with respect to the ''master phase reference” signal at the rear of the
instrument | 10 to 100 % |
| 13 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 13 of 79
Channel to Channel Phase Difference Measure
Frequency
Voltage channel relative to: (±) CMC2, 4, 13
Any Other
Voltage Channel
Any Current Range
(Percent of Range)
Another Measurement
Using the Same Calibration
System Voltage Range 10 % 100 %
16 Hz 1.3
4.3
1.1
1.3
40 Hz
1.4
1.2 50 Hz
4.4
60 Hz 1.4
120 Hz 1.9 5.4 1.7
180 Hz 2.8 5.5 2.3
1.7 450 Hz 5.7 6.3 4.9
850 Hz 11 10 8.9
1.2 kHz 16 14 14
5.1
1.8 kHz 23 20 20
2.4 kHz 30 26 26
3 kHz 37 32 32
3.6 kHz 45 38 38
4.2 kHz 52 44 44 6.5
4.8 kHz 60 50 50
9.4 5.4 kHz 67 57 57
6 kHz 74 63 63
Comments
Uncertainty applies from (10 to 100) % of range & are in m˚
Fluke 61XXA calibration station. | 10 to 100 % |
| 14 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 14 of 79
Phase Generate
Range Frequency
(±) CMC2, 13
Comments
0° (200 to 1000) kHz (Freq [Hz] ꞏ 2.0E-08)° Coupler
(0 to 360)° 1 Hz to 6.25 kHz 10 m ° Clarke Hess 5500 phase
standard (6.25 to 200) kHz 36 m °
Comments For calibration of Fluke internal phase meters
Phase Measure
Range Frequency (±) CMC 2, 13
(0 to 360)°
5 Hz to 2 kHz 0.02°
(2 to 5) kHz 0.03°
(5 to 10) kHz 0.04°
(10 to 50) kHz 0.05°
Comments Clarke-Hess 6000A used in calibration of Fluke 55XX calibrators
(Table 1 of 3)
AC Resistance Generate &
AC Resistance Measure (±) CMC2, 4, 5, 13
AC Resistance Frequency Comments
60 Hz 100 Hz 1 kHz
(25 to 500) mΩ 0.31 %
Calibration of Fluke 5320A
(ground bond resistance
decade f = 60 Hz)
Calibration of Hioki
IM3533
100 mΩ 69 µ Ω/Ω
(1 to 180) Ω 0.12 %
(0.5 to 1.8) kΩ 0.08 %
1 Ω
76 µΩ/Ω 34 µ Ω/Ω
General Radio 1689M
For calibration of Fluke
55XX station, 63XX
transfer resistors, & Hioki
IM3533
5 Ω 0.055 % 0.027 % | 0 to 360 ° |
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 15 of 79
(Table 2 of 3)
AC Resistance Generate &
AC Resistance Measure (±) CMC2, 4, 5, 13
AC Resistance Frequency Comments
60 Hz 100 Hz 1 kHz
10 Ω
47 µΩ/Ω 24 µ Ω/Ω General Radio 1689M
For calibration of Fluke
55XX station, Fluke
63XX transfer resistors, &
Hioki IM3533
100 Ω to 100 kΩ 60 µ Ω/Ω 16 µ Ω/Ω
2 MΩ 0.20 % 0.070 %
100 MΩ 8.5 % 3.0 %
10 kΩ to 5 MΩ 0.20 % Calibration of Fluke
5320A load
(Table 3 of 3)
AC Resistance Generate &
AC Resistance Measure (±) CMC2, 4, 13
AC Resistance Frequency Comments
0.1 Hz 1 Hz 10 Hz 100 Hz to 100 kHz
1000 Ω 17
µΩ/Ω
16
µΩ/Ω
18
µΩ/Ω 16 µΩ/Ω
Calibration of Hioki
IM3533 / Fluke
PM6306 | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 16 of 79
(Table 1 of 6)
AC Voltage Generate (Fixed Points)
Frequency
AC Voltage (±) CMC2, 4, 5, 6, 13
0.6 mV 2 mV 6 mV 10 mV 20 mV 60 mV 100 mV 120 mV 200 mV
10 Hz
0.020 % 80 μV/V
70 μV/V 0.010 % 55 μV/V 35 μV/V
20 Hz 60 μV/V 67 μV/V 23 μV/V
40 Hz 50 μV/V 38 μV/V
18 μV/V
100 Hz
40 μV/V
47 μV/V
1 kHz 0.070 % 67
μV/V 38 μV/V 25 μV/V
10 kHz
48 μV/V
20 kHz 53 μV/V 17 μV/V
50 kHz 50 μV/V 72 μV/V 23 μV/V
100 kHz 0.022 % 90 μV/V 85 μV/V 0.014 % 36 μV/V
300 kHz 0.030 % 0.021 % 0.020 % 0.027 % 80 μV/V
500 kHz 0.036 % 0.026 % 0.025 % 0.035 % 0.011 %
1 MHz 0.13 % 0.055 % 0.04 % 0.041 % 0.018 %
Comments Fluke 792 AC/DC transfer standard (with AC divider if needed)
to calibrate Fluke 5790A | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 17 of 79
(Table 2 of 6)
AC Voltage Generate (Fixed Points)
Frequency AC Voltage (±) CMC2, 4, 13
600 mV 1 V 2 V 6 V 10V 19 V
10 Hz 26 μV/V 26 μV/V 25 μV/V 25 μV/V 26 μV/V
20 Hz 20 μV/V 23 μV/V 20 μV/V 20 μV/V 22 μV/V
30 Hz 20 μV/V 21 μV/V
40 Hz 10 μV/V 17 μV/V 8.0 μV/V 8.0 μV/V 18 μV/V
55 Hz 15 μV/V 17 μV/V
100 Hz 10 μV/V
7 μV/V
7 μV/V 8.0 μV/V
300 Hz 9.0 μV/V
1 kHz 12 μV/V 6 μV/V 8.0 μV/V
8.0 μV/V
8.0 μV/V
3 kHz
10 kHz
11 μV/V 6 μV/V 7.0 μV/V
20 kHz
9.0 μV/V
30 kHz
50 kHz 10 μV/V
8 μV/V
8 μV/V 7.0 μV/V
10 μV/V
60 kHz
100 kHz 12 μV/V 10 μV/V 10 μV/V 8.0 μV/V 11 μV/V
300 kHz 30 μV/V 25 μV/V 25 μV/V 23 μV/V 23 μV/V
500 kHz 32 μV/V 26 μV/V 26 μV/V 28 μV/V 28 μV/V
1 MHz 65 μV/V 45 μV/V 45 μV/V 45 μV/V 45 μV/V
Comments Fluke 792 AC/DC transfer standard (with AC divider if needed)
to calibrate Fluke 5790A & Fluke 8508A | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 18 of 79
(Table 3 of 6)
AC Voltage Generate (Fixed Points)
Frequency AC Voltage (±) CMC2, 4, 13
20 V 60 V 100 V 200 V 500 V
10 Hz 25 μV/V 26 µV/V 26 µV/V 36 µV/V
20 Hz 30 μV/V 22 µV/V 22 µV/V 23 µV/V
40 Hz 8.0 μV/V 10 µV/V
18 µV/V
50 Hz
24 µV/V
55 Hz
100 Hz 8.0 μV/V 10 µV/V 10 µV/V 18 µV/V
300 Hz 20 µV/V
1 kHz 8.0 μV/V 10 µV/V 10 µV/V 13 µV/V
15 µV/V 3 kHz
10 kHz
8.0 μV/V 10 µV/V 10 µV/V
13 µV/V
20 kHz 14 µV/V
30 kHz 17 µV/V
50 kHz 8.0 μV/V 12 µV/V 12 µV/V 16 µV/V
60 kHz 30 μV/V
100 kHz 10 μV/V 15 µV/V 15 µV/V 21 µV/V 41 μV/V
300 kHz 25 μV/V 30 µV/V 30 µV/V
500 kHz 30 μV/V
1 MHz 45 μV/V
Comments Fluke 792 AC/DC transfer standard (with AC divider if needed)
to calibrate Fluke 5790A & Fluke 8508A
(Table 4 of 6)
AC Volta
ge Generate (Fixed Points)
Frequency AC Voltage (±) CMC2, 4, 5, 13
5 V
1 kHz 0.040 %
Comments Calibration of Fluke 8508A | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 19 of 79
(Table 5 of 6)
AC Voltage Generate (Fixed Points)
Frequency
AC Voltage (±) CMC2, 4, 5, 13
10 mV 100
mV
500 mV 50 V 250 V 600 V 700 V 1000 V
10 Hz
50 µV/V
15 Hz 40
µV/V
20 Hz 74
μV/V
21 µV/V
40 Hz 32
μV/V 18 μV/V 23
µV/V
55 Hz 37
μV/V
100 Hz 21
µV/V
300 Hz 45
μV/V
1 kHz 0.027 % 36
μV/V 12 μV/V 15
µV/V
18 µV/V 3 kHz
40
μV/V
10 kHz 35
μV/V
15
µV/V
20 kHz 40
μV/V 11 μV/V 16
µV/V 19 µV/V
30 kHz 50
μV/V
24 µV/V
50 kHz 60
μV/V
20
µV/V
28
µV/V
60 kHz 84
μV/V
100 kHz 100
μV/V 23 μV/V 40
µV/V
38
µV/V
300 kHz 200
μV/V 70 μV/V 40
µV/V
1 MHz 0.12 % 0.014 %
Comments Calibration of Fluke 5790A or reference multimeters | ||
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 20 of 79
(Table 6 of 6)
AC Voltage Generate (Fixed Points)
Frequency AC Voltage (±) CMC2, 4, 5, 13
1 V 3 V
2 MHz
0.60 % 0.50 %
4 MHz
8 MHz
10 MHz
Comments Calibration of reference multimeters | ||
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 21 of 79
(Table 1 of 2)
AC Voltage Generate (Fixed Points)
Frequency
AC Voltage (±) CMC2, 4, 6, 13
10 mV 22 mV 100 mV 120
mV
200
mV
400
mV
600
mV
800
mV
1 V
10 Hz 210
uV/V 34 uV/V 25 μV/V
40 Hz 210
uV/V 25 uV/V 24 μV/V
105 Hz 210
uV/V 25 uV/V 17 μV/V
1 kHz 210
uV/V
60
uV/V
25 uV/V 22
μV/V
21
μV/V
21
μV/V
21
μV/V
17
μV/V 17 μV/V
2 kHz 210
uV/V 25 uV/V 17 μV/V
10 kHz 210
uV/V 25 uV/V 17 μV/V
30 kHz 210
uV/V 27 uV/V 20 μV/V
60 kHz 210
uV/V 66 uV/V 64 μV/V
100 kHz 250
uV/V 130
μV/V 130
μV/V
200 kHz
300 kHz 710
uV/V 660
μV/V 660
μV/V
1 MHz 2500
uV/V 2500
μV/V 2300
μV/V
2 MHz 2600
μV/V
2600
μV/V
4 MHz 5200
μV/V
5200
μV/V
6 MHz 9600
μV/V
9600
μV/V
8 MHz 16 000
μV/V
16 000
μV/V
10 MHz 12 000
μV/V
21 000
μV/V
Comments
Calibration of 8588A characterized station using 5720A/5725A | ||
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 22 of 79
(Table 2 of 2)
AC Voltage Generate (Fixed Points)
Frequency
AC Voltage (±) CMC2, 4, 6, 13
1.2V 10 V 20 V 100 V 120 V 500V 1000 V
10 Hz 21 μV/V 30 μV/V
40 Hz 17 μV/V 20 μV/V 20 μV/V 21 μV/V
105 Hz 17 μV/V 20 μV/V 20 μV/V
1 kHz 17 μV/V 17 μV/V 20 μV/V 20 μV/V 20 μV/V 20 μV/V
2 kHz 17 μV/V 20 μV/V 20 μV/V 20 μV/V
10 kHz
17 μV/V 20 μV/V 20 μV/V 23 μV/V
30 kHz 19 μV/V 89 μV/V 71 μV/V 81 μV/V
60 kHz 64 μV/V 150 μV/V 210 μV/V
100 kHz 120 μV/V 180 μV/V 260 μV/V
200 kHz 600
μV/V
460 μV/V
300 kHz 590 μV/V 1100
μV/V
1 MHz 1200 μV/V 8600
μV/V
2 MHz 1500 μV/V
4 MHz 4800 μV/V
6 MHz 9400 μV/V
8 MHz 16 000 μV/V
10 MHz 21 000 μV/V
Comments Calibration of 8588A characterized station using 5720A/5725A | ||
| 23 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 23 of 79
(Table 1 of 2)
AC Voltage Generate
Frequency AC Voltage (±) CMC2, 13
(1 to 2.2) mV (2.2 to 22) mV (22 to 220) mV (0.22 to 2.2) V
(10 to 20) Hz 0.33 % + 4 µV 0.030 % + 4.0 µV 0.030 % + 12 µV 0.030 % + 40 µV
(20 to 40) Hz
0.34 % + 4 µV 0.020 % + 4.0 µV
97 µV/V + 7.0 µV 95 µV/V + 7.0 µV
40 Hz to 20 kHz 82 µV/V + 7.0 µV 49 µV/V + 8.0 µV
(20 to 50) kHz 0.35 % + 4 µV 0.030 % + 4.0 µV 0.030 % + 7.0 µV 80 µV/V + 10 µV
(50 to 100) kHz 0.38 % + 5 µV 0.060 % + 5.0 µV 0.050 % + 17 µV 0.020 % + 30 µV
(100 to 300) kHz 0.47 % + 20 µV 0.11 % + 10 µV 0.090 % + 20 µV 0.050 % + 80 µV
(300 to 500) kHz 0.61 % + 10 µV 0.15 % + 20 µV 0.14 % + 25 µV 0.10 % + 0.20 mV
(0.5 to 1) MHz 0.71 % + 20 µV 0.28 % + 20 µV 0.27 % + 45 µV 0.18 % + 0.30 mV
Comments Fluke 5720A Series II For calibration of long scale & bench DMMs
(Table 2 of 2)
AC Voltage Generate
Frequency AC Voltage (±) CMC2, 13
(2.2 to 22) V (22 to 220) V (220 to 1000) V
(10 to 20) Hz 0.030 % + 0.40 mV 0.030 % + 4.0 µV
0.030 % + 16 µV
(20 to 40) Hz 95 µV/V + 0.15 mV 97 µV/V + 1.5 µV
(40 to 50) Hz
49 µV/V + 50 µV 56 µV/V + 0.60 µV
94 µV/V + 4.0 µV
(50 to 1000) Hz 77 µV/V + 3.5 µV
(1 to 20) kHz 0.020 % + 6.0 µV
(20 to 30) kHz
80 µV/V + 0.10 mV 90 µV/V + 1.0 µV 0.060 % + 11 µV
(30 to 50) kHz
(50 to 100) kHz 0.020 % + 0.20 mV 0.020 % + 2.5 µV 0.23 % + 45 µV
(100 to 300) kHz 0.030 % + 0.60 mV
(300 to 500) kHz 0.10 % + 2.0 mV
(0.5 to 1) MHz 0.16 % + 3.2 mV
Comments Fluke 5720A Series II (w/ a Fluke 5725A if needed)
For calibration of long scale & bench DMMs | ||
| 24 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 24 of 79
(Table 1 of 4)
AC Voltage Measure
Frequency AC Voltage (±) CMC2, 4, 5, 13
0.6 mV (1 to 2.2) mV (2.2 to 7) mV (7 to 22) mV
(9.5 to 10) Hz
780 µV/V + 1.2
µV
780 µV/V + 1.2
µV
780 µV/V + 1.2
µV
(10 to 20) Hz
0.026 % + 1 µV
0.014 % + 1 µV
70 μV/V + 1 µV
(20 to 40) Hz
0.011 % + 1 µV
(40 to 1000) Hz
0.028 % + 1 µV 50 μV/V + 1 µV 1 kHz 0.20 %
(1 to 20) kHz
(20 to 50) kHz 0.029 % + 1.6 µV 0.011 % + 1.6 µV 60 μV/V + 1.6 µV
(50 to 100) kHz 0.032 % + 1.9 µV 0.018 % + 1.9 µV 0.01 % + 1.9 µV
(100 to 300) kHz 0.053 % + 3.1 µV 0.048 % + 3.1 µV 0.024 % + 3.1 µV
(300 to 500) kHz 0.073 % + 4.7 µV 0.059 % + 4.7 µV 0.032 % + 4.7 µV
(0.5 to 1) MHz 0.19 % + 4.7 µV 0.085 % + 4.7 µV 0.049 % + 4.7 µV
Comments Fluke 792A or Fluke 5790A transfer standard for calibration of long scale DMM
calibration stations, Fluke 55XX & Fluke 57XX calibrators | ||
| 25 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 25 of 79
(Table 2 of 4)
AC Voltage Measure
Frequency AC Voltage (±) CMC2, 5, 13
(22 to 70) mV (70 to 220) mV (220 to 700) mV (0.7 to 2.2) V
(9.5 to 10) Hz 780 µV/V + 1.2
µV
780 µV/V + 1.2
µV
780 µV/V + 1.2
µV 780 µV/V
(10 to 20) Hz 0.012 % + 1.2 µV 60 μV/V + 1.2 µV
50 μV/V 40 μV/V
(20 to 40) Hz 93 µV/V + 1.2 µV 50 μV/V + 1.2 µV
40 Hz to 20 kHz 50 μV/V + 1.2 µV 29 μV/V + 1.2 µV 24 μV/V + 1.2 µV 17 μV/V
(20 to 50) kHz 80 μV/V + 1.6 µV 50 μV/V + 1.6 µV 39 μV/V + 1.6 µV
30 μV/V
(50 to 100) kHz 0.014 % + 1.9 µV 90 μV/V + 1.9 µV 61 μV/V + 1.9 µV
(100 to 300) kHz 0.029 % + 3.1 µV 0.014 % + 3.1 µV 120 μV/V + 3.1
µV 0.01 %
(300 to 500) kHz 0.038 % + 4.7 µV 0.013 % + 4.7 µV 0.017 %
(0.5 to 1) MHz 0.051 % + 4.7 µV 0.031 % + 4.7 µV 0.023 % 0.011 %
Comments Fluke 792A or Fluke 5790A transfer standard for calibration of long scale DMM
calibration stations, Fluke 55XX & Fluke 57XX calibrators
(Table 3 of 4)
AC Voltage Measure
Frequency AC Voltage (±) CMC2, 5, 13
(2.2 to 7) V (7 to 22) V (22 to 70) V
(9.5 to 10) Hz 780 µV/V 780 µV/V 780 µV/V
(10 to 20) Hz
40 μV/V
90 μV/V
40 μV/V
(20 to 40) Hz 40 μV/V
40 Hz to 20 kHz 17 μV/V 19 μV/V 23 μV/V
(20 to 50) kHz
30 μV/V 30 μV/V 40 μV/V
(50 to 100) kHz
(100 to 300) kHz
0.01 % 80 μV/V
0.01 %
(300 to 500) kHz 310 µV/V
(0.5 to 1) MHz 0.011 % 0.011 % 850 µV/V
Comments Fluke 792A or Fluke 5790A transfer standard for calibration of long scale DMM
calibration stations, Fluke 55XX & Fluke 57XX calibrators | ||
| 26 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 26 of 79
(Table 4 of 4)
AC Voltage Measure
Frequency AC Voltage (±) CMC2, 5, 13
(70 to 220) V (220 to 700) V (700 to 1050) V
(10 to 20) Hz 90 μV/V 0.010 %
(20 to 40) Hz 50 μV/V 60 μV/V 50 μV/V
40 Hz to 20 kHz 22 μV/V 30 μV/V 29 μV/V
(20 to 50) kHz 40 μV/V 37 μV/V 40 μV/V
(50 to 100) kHz 50 μV/V 60 μV/V 60 μV/V
(100 to 300) kHz 0.011 %
(300 to 500) kHz 340 μV/V
Comments Fluke 792A or Fluke 5790A transfer standard for calibration of long scale DMM
calibration stations, Fluke 55XX & Fluke 57XX calibrators
AC Voltage Measure
(Non-Sinusoidal Waveforms)
Frequency AC Voltagep-p (±) CMC2, 5, 13
(1 to 22) mV (22 to 700) mV (0.7 to 70) V
(10 to 45) Hz 780 µV/V + 1.0 µV 780 µV/V + 1.2 µV 780 µV/V
45 Hz to 1 kHz 780 µV/V + 1.0 µV 780 µV/V + 1.2 µV 780 µV/V
(1 to 20) kHz 0.13 % + 1.0 µV 0.13 % + 1.2 µV 0.13 %
(20 to 100) kHz 0.39 % + 1.9 µV 0.39 %
Comments Fluke 5790B AC measurement standard for calibration of Fluke 55XX calibrators | ||
| 27 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 27 of 79
(Table 1 of 2)
AC Voltage Measure (Ranges)
Frequency AC Voltage (±) CMC2, 4, 13
0.25 V 1.5 V 2.4 V 10 V 23 V 45 V
DC 34 34 34 32 34 34
16 Hz 31
25
38 28 31 31
40 Hz
25 27 22
22 20
50 Hz 23 21
60 Hz
25 25 120 Hz
180 Hz
450 Hz 25 25
850 Hz 27 28 29 24 28 28
1.2 kHz
36 36 37 34 36 36
1.8 kHz
2.4 kHz
3.0 kHz
3.6 kHz
4.2 kHz
4.8 kHz
5.4 kHz
6.0 kHz
Comments
Note: All uncertainties in µV/V
Fluke 61XXA calibration system | ||
| 28 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 28 of 79
(Table 2 of 2)
AC Voltage Measure (Ranges)
Frequency
AC Voltage (±) CMC2, 4, 13
90 V Range Linearity
7 V 90 V 180 V 360V 1008 V
DC 36 34 34 34 34
16 Hz
56
31 38 38 38
40 Hz
25 27 27 27
50 Hz
60 Hz
120 Hz
180 Hz
450 Hz
850 Hz 56 25 28 29 29
1.2 kHz 60
36 37 37 37
1.8 kHz 70 2.4 kHz
3.0 kHz
80
3.6 kHz
4.2 kHz
4.8 kHz
5.4 kHz
6.0 kHz
Comments
Note: All uncertainties in µV/V
Fluke 61XXA calibration system | ||
| 29 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 29 of 79
(Table 1 of 4)
AC Current Measure (Fixed Points)
Frequency AC Current (±) CMC2, 4, 5, 13
20 μA 200 μA 300 μA 2 mA 3 mA 20 mA 200 mA 2 A
10 Hz
80
μA/A
0.010
%
75
μA/A 0.010
%
0.012
%
0.012
%
20 Hz 65
μA/A
55
μA/A
65
μA/A
65
μA/A
70
μA/A
40 Hz 55
μA/A
45
μA/A 45
μA/A
45
μA/A
45 Hz 75
μA/A
65
μA/A
1 kHz 0.015
%
55
μA/A
45
μA/A
45
μA/A
45
μA/A 65
μA/A 5 kHz 0.016
%
0.020
%
75
μA/A
85
μA/A
65
μA/A
65
μA/A
10 kHz 0.050
%
0.027
%
0.025
%
0.010
%
0.010
%
0.010
%
0.010
%
0.010
%
30 kHz 0.050
% 0.015
%
Comments Multifunction calibrator calibration
(Table 2 of 4)
AC Current Measure (Fixed Points)
Frequency AC Current (±) CMC2, 4, 13
329 µA 0.33 mA 1.9 mA 3.29 mA 3.3 mA 19 mA
10 Hz
170 µA/A
45 Hz
42 µA/A 1 kHz 99 µA/A
99 µA/A
47 µA/A
42 µA/A
39 µA/A
5 kHz
10 kHz 98 µA/A 46 µA/A 41 µA/A 39 µA/A
30 kHz 160 µA/A 160 µA/A 70 µA/A 53 µA/A 53 µA/A 52 µA/A
Comments Fluke A40B with Fluke 5790B (calibration of Fluke 55XX calibrators) | ||
| 30 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 30 of 79
(Table 3 of 4)
AC Current Measure (Fixed Points)
Frequency AC Current (±) CMC2, 4, 13
32.9 mA 33 mA 190 mA 329 mA 0.33 A 1.09 A
10 Hz 170 µA/A
170 µA/A
170 µA/A
45 Hz
37 µA/A
39 µA/A
43 µA/A
1 kHz 37 µA/A 41 µA/A
38 µA/A 38 µA/A 5 kHz
38 µA/A
38 µA/A
10 kHz 41 µA/A
30 kHz 50 µA/A 50 µA/A 54 µA/A 51 µA/A
Comments Fluke A40B with Fluke 5790B (calibration of Fluke 55XX calibrators)
(Table 4 of 4)
AC Current Measure (Fixed Points)
Frequency AC Current (±) CMC2, 4, 13
2.19 A 2.99 A 3.3 A 10.9 A 20 A
10 Hz 170 µA/A 170 µA/A
45 Hz 51 µA/A 47 µA/A 82 µA/A
48 µA/A
65 Hz
83 µA/A
500 Hz 52 µA/A 90 µA/A 60 µA/A
1 kHz 56 µA/A 52 µA/A 51 µA/A 89 µA/A 59 µA/A
5 kHz 56 µA/A 53 µA/A 52 µA/A 97 µA/A 71 µA/A
10 kHz
Comments Fluke A40B with Fluke 5790B (calibration of Fluke 55XX calibrators) | to 20 A |
| 31 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 31 of 79
(Table 1 of 3)
AC Current Generate (Fixed Points)
Frequency AC Current (±) CMC2, 4, 13
10 µA 20 µA 100 µA 200 µA 1 mA
10 Hz 470 µA/A 150 µA/A 86 µA/A
55 Hz 480 µA/A 120 µA/A 70 µA/A
305 Hz 470 µA/A 120 µA/A 70 µA/A
1 kHz 470 µA/A 470 µA/A 120 µA/A 140 µA/A 70 µA/A
2 kHz 470 µA/A 120 µA/A 73 µA/A
5 kHz 470 µA/A 120 µA/A 70 µA/A
10 kHz 470 µA/A 150 µA/A 78 µA/A
20 kHz 210 µA/A 88 µA/A
30 kHz 310 µA/A 94 µA/A
Comments Calibration of 8588A characterized station using 5720A/5725A
(Table 2 of 3)
AC Current Generate (Fixed Points)
Frequency AC Current (±) CMC2, 4, 13
2 mA 10 mA 20 mA 100 mA 200 mA
10 Hz 77 µA/A 78 µA/A
55 Hz 66 µA/A 74 µA/A
305 Hz 66 µA/A 70 µA/A
1 kHz 56 µA/A 66 µA/A 65 µA/A 70 µA/A 77 µA/A
2 kHz 70 µA/A 70 µA/A
5 kHz 66 µA/A 70 µA/A
10 kHz 75 µA/A 74 µA/A
20 kHz 98 µA/A 110 µA/A
30 kHz 98 µA/A 120 µA/A
Comments Calibration of 8588A characterized station using 5720A/5725A | ||
| 32 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 32 of 79
(Table 3 of 3)
AC Current Generate (Fixed Points)
Frequency AC Current (±) CMC2, 4, 13
300 mA 1.0 A 2.0 A 10.0 A 30 A
10 Hz 98 µA/A 110 µA/A
55 Hz 90 µA/A 100 µA/A
305 Hz 89 µA/A 89 µA/A
1 kHz 89 µA/A 84 µA/A 89 µA/A 89 µA/A
2 kHz 89 µA/A 89 µA/A
5 kHz 100 µA/A 100 µA/A
10 kHz 130 µA/A 100 µA/A
20 kHz 56 µA/A
30 kHz 56 µA/A
Comments Calibration of 8588A characterized station using 5720A/5725A | ||
| 33 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 33 of 79
(Table 1 of 2)
AC Current Measure & AC Current Generate
Frequency
AC Current (±) CMC2, 4, 13
(10 to 200)
µA
(0.2 to 2) mA (2 to 20) mA (20 to 200)
mA
(0.2 to 2) A
10 Hz 75 μA/A
+ 5.4 nA
86 μA/A
+ 21 nA
80 μA/A
+ 0.21 µA
63 μA/A
+ 2.1 µA
70 μA/A
+ 21 µA
(10 to 20) Hz 78 μA/A
+ 5.4 nA
50 μA/A
+ 21 nA
58 μA/A
+ 0.21 µA
58 μA/A
+ 2.1 µA
61 μA/A
+ 21 µA
(20 to 30) Hz 62 μA/A
+ 0.21 µA
63 μA/A
+ 2.1 µA
68 μA/A
+ 21 µA
(30 to 40) Hz 74 μA/A
+ 5.4 nA
53 μA/A
+ 0.21 µA
52 μA/A
+ 2.1 µA
55 μA/A
+ 21 µA
(40 to 55) Hz 57 μA/A
+ 0.21 µA
58 μA/A
+ 2.1 µA
62 μA/A
+ 21 µA
(55 to 300) Hz 87 μA/A
+ 5.4 nA 51 μA/A
+ 21 nA
58 μA/A
+ 0.21 µA
57 μA/A
+ 2.1 µA
63 μA/A
+ 21 µA
(0.3 to 1) kHz 78 μA/A
+ 5.4 nA
53 μA/A
+ 0.21 µA
52 μA/A
+ 2.1 µA
55 μA/A
+ 21 µA
(1 to 5) kHz 0.012 %
+ 5.4 nA
76 μA/A
+ 21 nA
82 μA/A
+ 0.21 µA
78 μA/A
+ 2.1 µA
82 μA/A
+ 21 µA
(5 to 10) kHz 0.031 %
+ 5.4 nA
0.020 %
+ 21 nA
0.021 %
+ 0.21 µA
0.020 %
+ 2.1 µA
0.022 %
+ 21 µA
(10 to 20) kHz 0.034 %
+ 7.1 nA
0.031 %
+ 51 nA
0.032 %
+ 0.51 µA
0.032 %
+ 5.0 µA
0.032 %
+ 50 µA
(20 to 30) kHz 0.053 %
+ 12 nA
0.051 %
+ 0.10 µA
0.051 %
+ 1.1 µA
0.051 %
+ 10 µA
0.052 %
+ 100 µA
Comments Fluke A40/A40A with a Fluke 792A or Fluke 5790A (calibration of Fluke 55XX
& Fluke 57XX calibrators)
(Table 2 of 2)
AC Current Measure & AC Current Generate
Frequency AC Current (±) CMC2, 5, 13
(2 to 20) A
(1 to 5) kHz 0.031 % + 0.21 mA
(5 to 10) kHz 0.061 % + 0.21 mA
(10 to 20) kHz 0.11 % + 0.51 mA
Comments Fluke A40/A40A with a Fluke 792A or Fluke 5790A (calibration of Fluke 55XX
& Fluke 57XX calibrators) | 10 to 20 kHz |
| 34 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 34 of 79
(Table 2 of 3)
AC Current Generate (±) CMC2, 5, 13
Frequency
(45 to 100) Hz (100 to 1000) Hz
(3 to 10.9999) A 0.039 % + 1.6 mA 0.062 % + 1.6 mA
(11 to 20.5) A 0.078 % + 3.9 mA 0.10 % + 3.9 mA
Comments Fluke 5522A calibration of Fluke 280-series multimeters
(Table 3 of 3)
AC Current Generate using Transconductance Amplifier (±) CMC2, 13
Frequency
(10 to 45) Hz (45 to 65) Hz (65 to 300) Hz (300 to 1000) Hz
(2 to 20) A 0.026 % + 27 mA 0.016 % + 27 mA 0.026 % + 27 mA 0.078 % + 27 mA
(20.0001 to
32.9999) A 0.026 % + 31 mA 0.016 % + 31 mA
0.026 % + 37 mA
0.078 % + 96 mA
(33 to 40) A 0.026 % + 38 mA
(40.001 to 120) A 0.026 % + 290 mA 0.016 % + 290
mA
0.026 % + 290
mA
0.078 % + 300
mA
Comments Calibration of clamp meters using a Fluke 5522A driving a Fluke 52120A into a
single wire
(Table 1 of 3)
AC Current Generate (±) CMC2, 13
Frequency
(10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz
(2 to 2.999 99) A 0.12 % + 78 μA 0.039 % + 78 μA 0.39 % + 780 µA 1.6 % + 3.9 mA | ||
| 35 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 35 of 79
Simulation of Flexible AC Current Probe (Rogowski Coil)
(Fixed Points)
Parameter/Equipment
Simulated
Current Frequency
(±) CMC2, 13
Comments
AC Current
Generate
50 A
35 Hz 260 mA
Simulation of
accessory probe
by a Fluke
55XXA into a
clamp meter
100 Hz 100 mA
500 Hz 62 mA
100 A 50 Hz 180 mA
600 A 60 Hz 270 mA
500 Hz 110 mA
900 A 50 Hz 270 mA
950 A
20 Hz 980 mA
100 Hz 220 mA
500 Hz 140 mA
995 A 50 Hz 280 mA
1000 A 500 Hz 140 mA
2000 A 50 Hz 720 mA
2450 A
20 Hz 2.0 A
100 Hz 690 mA
500 Hz 730 mA
2500 A
45 Hz 3.4 A
50 Hz 1.0 A
500 Hz 930 mA | ||
| 36 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 36 of 79
AC Current Measure
Frequency AC Current ( ±) CMC2, 4, 5, 13 Comments
(40 to 1000) Hz (2 to 11) A 0.040 % + 0.17 mA Fluke 5725A
(45 to 100) Hz
(11 to 20) A
0.076 % + 5 mA
Fluke 5520A
(100 to 1000) Hz 0.11 % + 5 mA
(16 to 450) Hz
(80 to 120) A
49 μA/A Fluke 52120A
transconductance amplifier
with Fluke 61XX
calibration system
850 Hz 51 μA/A
(1 to 6) kHz 0.011 %
Comments Calibration of Fluke 52120A, Fluke 55XX, Fluke 57XX & Fluke 61XX
calibrators
AC Current Generate (Fixed Points)
Frequency AC Current (±) CMC2, 4, 5, 6, 13
100 µA 1 mA 10 mA 100 mA 1 A 10 A 30 A
10 Hz 73 μA/A
55 Hz
60 μA/A
40 μA/A
40 μA/A
40 μA/A 50 μA/A
160 μA/A
300 Hz 50 μA/A 120 μA/A
1 kHz 45 μA/A 35 μA/A 30 μA/A 40 μA/A 90 μA/A 79 μA/A
5 kHz 75 μA/A 50 μA/A 40 μA/A 40 μA/A 80 μA/A 0.055 %
10 kHz 200 μA/A 95 μA/A 120 μA/A 110 μA/A 0.052 % 0.070 %
Comments Calibration of reference multimeters | 40 to 1000 Hz |
| 37 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 37 of 79
Table (1 of 2)
AC Current Measure (Ranges)
Frequency AC Current (±) CMC2, 4, 13
0.1 A 0.5 A 1 A 2 A 5 A
DC 26
27 27
26 28
16 Hz
27 27 32
40 Hz
50 Hz
60 Hz
120 Hz
180 Hz
450 Hz 25 25 25 24 30
850 Hz 27 27 27 27 32
1.2 kHz
28 29 29 28 34
1.8 kHz
2.4 kHz
3.0 kHz
3.6 kHz
4.2 kHz
4.8 kHz
5.4 kHz
6.0 kHz
Comments
Note: All uncertainties in µA/A
Fluke 61XX calibration system | ||
| 38 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 38 of 79
(Table 2 of 2)
AC Current Measure (Ranges)
Frequency
AC Current (±) CMC2, 4, 13
10 A Range Linearity
0.5 A 10 A 20 A 50 A 100 A
DC 42 28 28 27 33
16 Hz
45 34 34 34 38 40 Hz
50 Hz
60 Hz
120 Hz 78 35 41 50 61 180 Hz
450 Hz 46 34 40 48 60
850 Hz 47 35 41 50 61
1.2 kHz
48 37
42 62
1.8 kHz
51 59 80
2.4 kHz
3.0 kHz
3.6 kHz
4.2 kHz
4.8 kHz
5.4 kHz
6.0 kHz
Comments
Note: All uncertainties in μA/A
Fluke 61XX calibration system | ||
| 39 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 39 of 79
(Table 1 of 3)
AC Current Measure (Fixed Points)
Frequency AC Current (±) CMC2, 4, 5, 13
(5 to 10) mA (10 to 20) mA (20 to 30) mA (30 to 50) mA (50 to 100) mA
10 Hz
0.013 %
0.013 %
0.015 % 0.017 %
0.014 %
20 Hz 75 μA/A
40 Hz
75 μA/A
60 μA/A
95 μA/A 0.010 %
85 μA/A
400 Hz
1 kHz
5 kHz
75 μA/A 10 kHz
20 kHz
30 kHz 90 μA/A 90 μA/A 0.012 % 0.011 % 0.01 %
Comments Fluke 792 AC/DC transfer standard & a Fluke A40 AC/DC current shunt
(Table 2 of 3)
AC Current Measure (Fixed Points)
Frequency
AC Current (±) CMC2, 4, 5, 13
(100 to 200)
mA8
(200 to 300)
mA
(300 to 500)
mA
(0.5 to 1) A (1 to 2) A
10 Hz
0.013 % 0.015 % 0.016 % 0.015 %
0.012 %
20 Hz
0.011 %
40 Hz
80 μA/A
90 μA/A
0.010 %
90 μA/A
400 Hz
1 kHz
5 kHz
10 kHz 0.012 %
20 kHz
0.015 %
30 kHz 95 μA/A 0.012 %
Comments Fluke 792 AC/DC transfer standard & a Fluke A40 AC/DC current shunt | ||
| 40 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 40 of 79
(Table 3 of 3)
AC Current Measure (Fixed Points)
Frequency AC Current (±) CMC2, 4, 5, 13
(2 to 3) A (3 to 5) A (5 to 10) A (10 to 20 A)
10 Hz
0.015 % 0.018 %
0.015 %
0.017 % 20 Hz
40 Hz
0.010 % 0.011 %
400 Hz
0.013 %
1 kHz
5 kHz
0.016 %
10 kHz
Comments Fluke 792 AC/DC transfer standard & a Fluke A40 AC/DC current shunt
(Table 1 of 3)
AC Current Measure (Fixed Points)
Frequency
2 Amp Range (±) CMC2, 4, 13
V in I in
0.4 A 1.0 A 2.0 A 2.0 A
DC 51 µA/A 34 µA/A 28 µA/A 30 µA/A
(10, 16, 40, 50,
60, 120, 180,
450, 850, 1000)
Hz
160 µA/A 110 µA/A 100 µA/A 99 µA/A
(1.2, 1.8, 2.4)
kHz 210 µA/A 470 µA/A 480 µA/A 480 µA/A
(3.0, 3.6, 4.2)
kHz 210 µA/A 480 µA/A 490 µA/A 490 µA/A
4.8 kHz 270 µA/A 480 µA/A 490 µA/A 490 µA/A
5.4 kHz 270 µA/A 480 µA/A 500 µA/A 500 µA/A
6.0 kHz 290 µA/A 830 µA/A 830 µA/A 830 µA/A
8.0 kHz 750 µA/A 1100 µA/A 1100 µA/A 1100 µA/A
10 kHz 920 µA/A 1500 µA/A 1500 µA/A 1500 µA/A
Comments Fluke 61XXA calibration station Fluke 52120A (stand-alone mode) calibration | ||
| 41 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 41 of 79
(Table 2 of 3)
AC Current Measure (Fixed Points)
Frequency
20 Amp Range (±) CMC2, 4, 13
V in I in
4 A 10 A 20 A 20 A
DC 73 µA/A 73 µA/A 50 µA/A 51 µA/A
10 Hz 160 µA/A 91 µA/A 82 µA/A 83 µA/A
(16, 40, 50, 60,
120, 180, 450,
850, 1000
) Hz
160 µA/A 90 µA/A 80 µA/A 81 µA/A
(1.2, 1.8, 2.4,
3.0) kHz 490 µA/A 200 µA/A 190 µA/A
190 µA/A
(3.6, 4.2, 4.8,
5.4) kHz 490 µA/A 200 µA/A 200 µA/A
200 µA/A
6.0 kHz 490 µA/A 200 µA/A 210 µA/A 210 µA/A
8.0 kHz 500 µA/A 830 µA/A 840 µA/A 840 µA/A
10 kHz 1500 µA/A 840 µA/A 840 µA/A 840 µA/A
Comments Fluke 61XXA calibration station Fluke 52120A (stand-alone mode) calibration
(Table 3 of 3)
AC Current Measure (Fixed Points)
Frequency
120 Amp Range (±) CMC2, 4, 13
V in I in
20 A 60 A 120 A 100 A
DC 37 µA/A 37 µA/A 33 µA/A 37 µA/A
(10, 16, 40, 50,
60, 120, 180,
450, 850, 1000)
Hz
160 µA/A 84 µA/A 86 µA/A 73 µA/A
(1.2, 1.8, 2.4,
3.0) kHz 210 µA/A 200 µA/A 210 µA/A
200 µA/A
(3.6, 4.2) kHz 210 µA/A 220 µA/A 220 µA/A 210 µA/A
4.8 kHz 230 µA/A 220 µA/A 220 µA/A 210 µA/A
5.4 kHz 250 µA/A 240 µA/A 240 µA/A 230 µA/A
6.0 kHz 290 µA/A 260 µA/A 270 µA/A 260 µA/A
8.0 kHz 750 µA/A 740 µA/A 730 µA/A 740 µA/A
10 kHz 770 µA/A 750 µA/A 760 µA/A 760 µA/A
Comments Fluke 61XXA calibration station Fluke 52120A (stand-alone mode) calibration | ||
| 42 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 42 of 79
(Table 1 of 3)
AC Current Measure (Fixed Points)
Frequency 2 Amp Range (±) CMC2, 4, 13
0.4 A 1.0 A 2.0 A
DC 60 μA/A 48 μA/A 44 μA/A
(16, 40, 50, 60,
120, 180, 450,
850, 1000) Hz
79 μA/A 59 μA/A 49 μA/A
(1.2, 1.8, 2.4)
kHz 79 μA/A 59 μA/A 49 μA/A
3.0 kHz 90 μA/A 72 μA/A 64 μA/A
(3.6, 4.2, 4.8)
kHz 92 μA/A 76 μA/A 68 μA/A
(5.4, 6.0) kHz 98 μA/A 83 μA/A 76 μA/A
Comments Fluke 61XXA calibration station Fluke 52120A calibration (under Fluke 6105A
control)
(Table 2 of 3)
AC Current Measure (Fixed Points)
Frequency 20 Amp Range (±) CMC2, 4, 13
4 A 10 A 20 A
DC 78 μA/A 78 μA/A 78 μA/A
(16, 40, 50, 60,
120, 180, 450,
850, 1000) Hz
65 μA/A 65 μA/A
56 μA/A
(1.2, 1.8, 2.4,
3.0) kHz 71 μA/A 71 μA/A 63 μA/A
(3.6, 4.2, 4.8,
5.4) kHz 74 μA/A 74 μA/A 67 μA/A
6.0 kHz 78 μA/A 78 μA/A 70 μA/A
Comments Fluke 61XXA calibration station Fluke 52120A calibration (under Fluke 6105A
control) | ||
| 43 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 43 of 79
(Table 3 of 3)
AC Current Measure (Fixed Points)
Frequency 120 Amp Range (±) CMC2, 4, 13
20 A 60 A 100 A
DC 51 μA/A 52 μA/A 51 μA/A
(16, 40, 50, 60,
120, 180, 450,
850, 1000) Hz
79 μA/A 77 μA/A 72 μA/A
(1.2, 1.8, 2.4,
3.0) kHz 95 μA/A 92 μA/A 89 μA/A
3.6, 4.2, 4.8, 5.4,
6.0) kHz 97 μA/A 95 μA/A 92 μA/A
Comments Fluke 61XX calibration station Fluke 52120A calibration (under Fluke 6105A
control)
AC Current Phase Measure (Fixed Points)
Frequency All Ranges: 2 A, 20 A & 120 A
(±) CMC2, 4, 13
16 Hz 1.3 m°
40 Hz 1.8 m°
50 Hz 2.2 m°
60 Hz 2.5 m°
120 Hz 4.3 m°
180 Hz 6.4 m°
450 Hz 16 m°
850 Hz 30 m°
1.0 kHz 35 m°
1.2 kHz 58 m°
1.8 kHz 120 m°
2.4 kHz 130 m°
3.0 kHz 130 m°
3.6 kHz 150 m°
4.2 kHz 190 m°
4.8 kHz 220 m°
5.4 kHz 210 m°
6.0 kHz 240 m°
Comments Fluke 61XXA calibration station Fluke 52120A calibration (under
Fluke 6105A control) | ||
| 44 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 44 of 79
(Table 1 of 6)
AC Current Phase Measure (Fixed Points)
Frequency 2 Amp Range (±) CMC2, 4, 13
0.4 A 1.0 A 2.0 A
16 Hz 1.2 1.2 1.2
40 Hz 1.7 1.7 1.7
50 Hz 2.1 2.1 2.1
60 Hz 2.5 2.5 2.5
120 Hz 4.3 4.3 4.3
180 Hz 6.3 6.3 6.3
450 Hz 16 16 16
850 Hz 30 30 30
1.0 kHz 34 34 34
1.2 kHz 57 57 57
1.8 kHz 120 120 120
2.4 kHz 130 130 130
3.0 kHz 130 130 130
3.6 kHz 150 150 150
4.2 kHz 180 180 180
4.8 kHz 220 220 220
5.4 kHz 210 210 210
6.0 kHz 240 240 240
Comments
All uncertainties are in m°
Phase measurement uncertainty assuming a common Fluke 61XXA & Fluke 52120A
calibration system. Calibration of 61XXA | ||
| 45 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 45 of 79
(Table 2 of 6)
AC Current Phase Measure (Fixed Points)
Frequency 20 Amp Range (±) CMC2, 4, 13
4 A 10 A 20 A
16 Hz 1.2 1.2 1.2
40 Hz 1.7 1.7 1.7
50 Hz 2.1 2.1 2.1
60 Hz 2.5 2.5 2.5
120 Hz 4.3 4.3 4.3
180 Hz 6.4 6.4 6.4
450 Hz 16 16 16
850 Hz 30 30 30
1.0 kHz 34 34 34
1.2 kHz 57 57 57
1.8 kHz 120 120 120
2.4 kHz 130 130 130
3.0 kHz 130 130 130
3.6 kHz 150 150 150
4.2 kHz 180 180 180
4.8 kHz 220 220 220
5.4 kHz 210 210 210
6.0 kHz 240 240 240
Comments
All uncertainties are in m°
Phase measurement uncertainty assuming a common Fluke 61XXA & Fluke 52120A
calibration system. Calibration of 61XXA | ||
| 46 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 46 of 79
(Table 3 of 6)
AC Current Phase Measure (Fixed Points)
Frequency 120 Amp Range (±) CMC2, 4, 13
20 A 60 A 120 A
16 Hz 1.3 1.3 1.3
40 Hz 1.8 1.8 1.8
50 Hz 2.2 2.2 2.2
60 Hz 2.5 2.5 2.5
120 Hz 4.3 4.3 4.3
180 Hz 6.4 6.4 6.4
450 Hz 16 16 16
850 Hz 30 30 30
1.0 kHz 34 34 34
1.2 kHz 57 57 57
1.8 kHz 120 120 120
2.4 kHz 130 130 130
3.0 kHz 130 130 130
3.6 kHz 150 150 150
4.2 kHz 180 180 180
4.8 kHz 220 220 220
5.4 kHz 210 210 210
6.0 kHz 240 240 240
Comments
All uncertainties are in m°
Phase measurement uncertainty assuming a common Fluke 61XXA & Fluke 52120A
calibration system. Calibration of 61XXA | to 120 A |
| 47 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 47 of 79
(Table 4 of 6)
AC Current Phase Measure (Fixed Points)
Frequency 2 Amp Range (±) CMC2, 4, 13
0.4 A 1.0 A 2.0 A
16 Hz 1.4 1.4 1.4
40 Hz 2.5 2.5 2.5
50 Hz 3.1 3.1 3.1
60 Hz 3.7 3.7 3.7
120 Hz 6.9 6.9 6.9
180 Hz 11 11 11
450 Hz 26 26 26
850 Hz 49 49 49
1.0 kHz 57 57 57
1.2 kHz 78 78 78
1.8 kHz 140 140 140
2.4 kHz 170 170 170
3.0 kHz 190 190 190
3.6 kHz 230 230 230
4.2 kHz 260 260 260
4.8 kHz 310 310 310
5.4 kHz 330 330 330
6.0 kHz 360 360 360
Comments
All uncertainties are in m°
Phase measurement uncertainty when the Fluke 6105A is calibrated on a separate system | ||
| 48 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 48 of 79
(Table 5 of 6)
AC Current Phase Measure (Fixed Points)
Frequency 20 Amp Range (±) CMC2, 4, 13
4 A 10 A 20 A
16 Hz 1.4 1.4 1.4
40 Hz 2.5 2.5 2.5
50 Hz 3.1 3.1 3.1
60 Hz 3.7 3.7 3.7
120 Hz 6.9 6.9 6.9
180 Hz 11 11 11
450 Hz 26 26 26
850 Hz 49 49 49
1.0 kHz 57 57 57
1.2 kHz 78 78 78
1.8 kHz 140 140 140
2.4 kHz 170 170 170
3.0 kHz 190 190 190
3.6 kHz 230 230 230
4.2 kHz 260 260 260
4.8 kHz 310 310 310
5.4 kHz 330 330 330
6.0 kHz 360 360 360
Comments
All uncertainties are in m°
Phase measurement uncertainty when the Fluke 6105A is calibrated on a separate system | ||
| 49 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 49 of 79
(Table 6 of 6)
AC Current Phase Measure (Fixed Points)
Frequency 120 Amp Range (±) CMC2, 4, 13
20 A 60 A 120 A
16 Hz 1.5 1.5 1.5
40 Hz 2.5 2.5 2.5
50 Hz 3.1 3.1 3.1
60 Hz 3.7 3.7 3.7
120 Hz 6.9 6.9 6.9
180 Hz 11 11 11
450 Hz 27 27 27
850 Hz 49 49 49
1.0 kHz 57 57 57
1.2 kHz 78 78 78
1.8 kHz 140 140 140
2.4 kHz 170 170 170
3.0 kHz 190 190 190
3.6 kHz 230 230 230
4.2 kHz 260 260 260
4.8 kHz 310 310 310
5.4 kHz 330 330 330
6.0 kHz 360 360 360
Comments
All uncertainties are in m°
Phase measurement uncertainty when the Fluke 6105A is calibrated on a separate system | ||
| 50 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 50 of 79
Effective Current Transfer Ratio – Measure
Parameter Frequency ( ±) CMC2, 5, 13 Comments
25 Turn Coils
(50 to 400) Hz
0.085 % of ratio 1000 A max simulated current
50 Turn Coils 0.28 % of ratio 6000 A max simulated current
DC 0.25 % of ratio Calibration of Fluke 5500/COIL
Comments Calibration of Fluke 5500A/COIL, Fluke 52120A/COIL 3KA & Fluke
52120A/COIL 6KA current coils
(Table 1 of 4)
AC Current Using a Coil – Generate (±) CMC2, 3, 13
Clamp Type: Toroidal
AC Current Frequency
(45 to 64.999) Hz (65 to 99.999) Hz (100 to 440) Hz
(10 to 16.4995) A 0.23 % + 52 mA 0.62 % + 52 mA 0.63 % + 52 mA
(16.5 to 99.95) A 0.24 % + 56 mA 0.62 % + 56 mA 0.66 % + 68 mA
(100.00 to 149.95) A 0.24 % + 280 mA 0.62 % + 280 mA 0.66 % + 280 mA
(150 to 1025) A 0.24 % + 300 mA 0.62 % + 300 mA 0.99 % + 350 mA
Comments Calibration of Fluke 80i-600 using
Fluke 5522A, Fluke 5500A/COIL, & Fluke 8846A
(Table 2 of 4)
AC Current Using a Coil – Generate (±) CMC2, 3, 13
Clamp Type: Non-Toroidal
AC Current Frequency
(45 to 64.999) Hz (65 to 99.999) Hz (100 to 440) Hz
(10 to 16.4995) A 0.44 % + 34 mA 0.78 % + 34 mA 0.79 % + 34 mA
(16.5 to 99.95) A 0.44 % + 200 mA 0.78 % + 200 mA 0.81 % + 200 mA
(100.00 to 149.95) A 0.44 % + 340 mA 0.78 % + 340 mA 0.81 % + 340 mA
(150 to 1025) A 0.45 % + 750 mA 0.78 % + 750 mA 1.1 % + 780 mA
Comments Calibration of Fluke clamp meters
using Fluke 55XXA & Fluke 5500A/COIL | ||
| 51 | - | AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 51 of 79
(Table 3 of 4)
AC Current Using a Coil – Generate
Clamp Type: Non-Toroidal using Transconductance Amplifier
AC Current Frequency (±) CMC2, 3, 4, 13
(10 to 40) A (10 to 1000) Hz 0.54 % + 27 mA
(40.000 25 to 50) A (10 to 1000) Hz 0.54 % + 100 mA
(50.000 25 to 500) A (10 to 1000) Hz 0.54 % + 220 mA
(500.0025 to 824.9975) A (10 to 1000) Hz 0.54 % + 510 mA
(825 to 1000) A (10 to 1000) Hz 0.54 % + 530 mA
(1000.025 to 1400) A (10 to 1000) Hz 0.54 % + 1.3 A
Comments Calibration of Fluke 35X-series clamps
using Fluke 5522A with Fluke 52120A & Fluke 52120A/COIL3KA
(Table 4 of 4)
AC Current Using a Coil – Generate (±)
Clamp Type: Rogowski Coils
AC Current Frequency (±) CMC2, 3, 4, 13 Comments
(5.00025 to 15) A
(10 to 45) Hz 0.55 % + 0.70 A
Fluke 5522A with Fluke
52120A & Fluke
52120A/COIL3KA
(45 to 500) Hz 0.54 % + 0.70 A
(15.000 25 to 50) A
(10 to 45) Hz 0.55 % + 0.39 A
(45 to 500) Hz 0.54 % + 0.39 A
(50.000 25 to 150) A
(10 to 45) Hz 0.55 % + 0.73 A
(45 to 500) Hz 0.54 % + 0.73 A
(150.0025 to 500) A
(10 to 45) Hz 0.55 % + 0.45 A
(45 to 500) Hz 0.54 % + 0.45 A
(500.000 25 to 3000) A
(10 to 45) Hz 0.55 % + 2.5 A
(45 to 500) Hz 0.54 % + 2.5A
(3000.05 to 6000) A
(10 to 45) Hz 0.55 % + 4.7 A Fluke 5522A with Fluke
52120A & Fluke
52120A/COIL6KA (45 to 65) Hz 0.54 % + 4.7 A | See scope document |
| 52 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 52 of 79
(Table 1 of 3)
AC Voltage Flatness Measure
Frequency AC Voltage Flatness (±) CMC2, 4, 5, 13
5 mV 9.9 mV 10 mV (34, 39, 40) mV (99, 100, 340, 399, 400) mV
(50 to 400) MHz
1.0 %
0.80 %
0.80 %
0.80 %
0.70 %
(400 to 500) MHz
0.90 %
(500 to 900) MHz
0.90 % (0.9 to 1) GHz
1.1 %
0.90 % (1 to 1.1) GHz
0.80 %
(1.1 to 1.2) GHz
1.2 %
1.0 % (1.2 to 1.5) GHz
1.0 % 1.0 % 0.90 %
(1.5 to 1.6) GHz
1.3 %
(1.6 to 2.0) GHz
1.2 %
1.2 % 1.2 %
1.0 %
(2.0 to 2.1) GHz 1.4 % 1.3 % 1.3 %
Comments Agilent E4418B power meter & power sensors calibration of Fluke 55XX, Fluke
58XX & Fluke 9500 scope calibrators
(Table 2 of 3)
AC Voltage Flatness Measure
Frequency AC Voltage Flatness (±) CMC2, 4, 5, 13
1.2 V (1.3, 3.4) V 5.5 V
(50 to 100) MHz
0.60 %
0.85 % 0.85 %
(100 to 200) MHz
0.75 %
0.75 %
(200 to 300) MHz
0.65 %
0.70 %
(300 to 400) MHz 0.75 %
(400 to 600) MHz
0.70 %
0.70 %
0.70 %
(0.6 to 1.1) GHz
(1.1 to 1.2) GHz
1.0 % (1.2 to 1.6) GHz 0.95 %
(1.6 to 2.1) GHz 1.0 %
Comments Agilent E4418B power meter & power sensors calibration of Fluke 55XX, Fluke
58XX & Fluke 9500 scope calibrators | ||
| 53 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 53 of 79
(Table 3 of 3)
AC Voltage Flatness Measure
Frequency AC Voltage Flatness (±) CMC2, 5, 13
(5 to 10) mV 10 mV to 5.5 V
50 kHz to 10 MHz 0.20 % 0.10 %
Comments Fluke 5790 AC standard calibration of Fluke 55XX & Fluke 57XX calibrators
(Table 1 of 4)
AC Voltage Flatness Generate &
AC Voltage Flatness Measure
Frequency AC Voltage Flatness (±) CMC2, 5, 13
(1 to 2.2) mV (2.2 to 7) mV (7 to 22) mV (22 to 70) mV
(10 to 50) Hz 0.038 % 0.026 % 0.022 % 0.021 %
50 Hz to 100 kHz 0.021 % 0.012 % 0.010 % 0.009 %
(100 to 500) kHz
0.030 %
0.016 % 0.015 %
0.015 %
(500 to 700) kHz
0.020%
0.018 %
700 kHz to 1 MHz 0.017 %
(1 to 2) MHz 0.019 % 0.018 %
(2 to 4) MHz
0.050 %
0.033 %
0.030 % 0.027 %
(4 to 6) MHz
0.035 %
0.029 %
(6 to 8) MHz
0.040 % 0.035 % (8 to 9) MHz 0.036 %
(9 to 10) MHz 0.040 %
(10 to 12) MHz
0.065 % 0.055 %
0.050 % 0.047 %
(12 to 15) MHz 0.052 % 0.050 %
(15 to 17) MHz
0.080 %
0.062 % 0.060 % 0.055 %
(17 to 20) MHz 0.070 % 0.065 % 0.060 %
(20 to 23) MHz
0.13 %
0.10 % 0.090 % 0.090 %
(23 to 26) MHz 0.11 % 0.11 % 0.11 %
(26 to 28) MHz
0.15 %
0.13 % 0.12 % 0.12 %
(28 to 30) MHz 0.14 % 0.13 % 0.13 %
Comments Fluke 5720A, relative to a reference frequency calibration of Fluke 55XX &
Fluke 57XX calibrators | to 30 MHz |
| 54 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 54 of 79
(Table 2 of 4)
AC Voltage Flatness Generate &
AC Voltage Flatness Measure
Frequency AC Voltage Flatness (±) CMC2, 5, 13
(1 to 2.2) mV (2.2 to 7) mV (7 to 22) mV (22 to 70) mV
(30 to 35) MHz 0.17 % 0.16 % 0.16 % 0.15 %
(35 to 40) MHz 0.20 % 0.19 % 0.18 % 0.17 %
(40 to 45) MHz 0.22 % 0.21 % 0.20 % 0.19 %
(45 to 50) MHz 0.25 % 0.23 % 0.22 % 0.21 %
Comments Fluke 5720A, relative to a reference frequency calibration of Fluke 55XX &
Fluke 57XX calibrators
(Table 3 of 4)
AC Voltage Flatness Generate &
AC Voltage Flatness Measure
Frequency AC Voltage Flatness (±) CMC2, 5, 13
(70 to 220) mV (220 to 700) mV (0.7 to 2.2) V (2.2 to 7) V
(10 to 50) Hz 0.020 % 0.016 % 0.016 % 0.015 %
50 Hz to 100 kHz 0.009 % 0.0080 % 0.0075 % 0.0070 %
(100 to 500) kHz 0.014 % 0.014 % 0.013 % 0.013 %
(500 to 700) kHz
0.017 %
0.016 % 0.016 %
0.017 % 700 kHz to 1 MHz
(1 to 2) MHz 0.017 % 0.017 %
(2 to 4) MHz 0.025 % 0.024 % 0.023 %
0.025 %
(4 to 6) MHz 0.027 % 0.026 % 0.026 %
(6 to 8) MHz 0.031 %
0.030 %
0.028 % 0.028 %
(8 to 9) MHz
0.032 %
(9 to 10) MHz 0.030 % 0.030 %
(10 to 12) MHz 0.045 % 0.042 % 0.040 % 0.040 %
(12 to 15) MHz 0.046 % 0.045 % 0.045 % 0.045 %
(15 to 17) MHz 0.055 % 0.050 % 0.050 % 0.050 %
(17 to 20) MHz 0.060 % 0.060 % 0.060 % 0.060 %
Comments Fluke 5720A, relative to a reference frequency calibration of Fluke 55XX &
Fluke 57XX calibrators | to 50 MHz |
| 55 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 55 of 79
(Table 4 of 4)
AC Voltage Flatness Generate &
AC Voltage Flatness Measure
Frequency AC Voltage Flatness (±) CMC2, 5, 13
(70 to 220) mV (220 to 700) mV (0.7 to 2.2) V (2.2 to 7) V
(20 to 23) MHz 0.090 % 0.09 % 0.090 % 0.090 %
(23 to 26) MHz 0.10 % 0.10 % 0.10 % 0.10 %
(26 to 28) MHz 0.11 % 0.11 % 0.11 % 0.11 %
(28 to 30) MHz 0.12 % 0.12 % 0.12 % 0.13 %
(30 to 35) MHz 0.15 % 0.14 % 0.13 % 0.13 %
(35 to 40) MHz 0.16 % 0.16 % 0.15 % 0.15 %
(40 to 45) MHz 0.18 % 0.18 % 0.16 % 0.16 %
(45 to 50) MHz 0.20 % 0.20 % 0.18 % 0.18 %
Comments Fluke 5720A, relative to a reference frequency calibration of Fluke 55XX &
Fluke 57XX calibrators
Capacitance Measure
Capacitance Frequency ( ±) CMC2, 4, 13 Comments
(1 to 1000) nF 1 kHz 25 μF/F Andeen Hagerling
2500A option E | ||
| 56 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 56 of 79
Capacitance Generate
Capacitance Frequency ( ±) CMC2, 13 Comments
(0.19 to 0.3999) nF
10 Hz to 10 kHz
0.29 % + 7.8 pF
Fluke 5520A
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF 10 Hz to 3 kHz
(3.3 to 10.9999) nF
10 Hz to 1 kHz
0.15 % + 7.8 pF
(11 to 32.9999) nF
0.15 % + 78 pF
(33 to 109.999) nF
(110 to 329.999) nF 0.15 % + 230 pF
330 nF to 1.09 999 µF (10 to 600) Hz
0.15 % + 780 pF (1.1 to 3.29 999) µF (10 to 300) Hz
(3.3 to 10.9999) µF (10 to 150) Hz
(11 to 32.9999) µF (10 to 120) Hz 0.23 % + 23 nF
(33 to 109.999) µF (10 to 80) Hz 0.26 % + 78 nF
(110 to 329.999) µF (0 to 50) Hz 0.26 % + 0.23 µF
330 µF to 1.099 99 mF (0 to 20) Hz 0.26 % + 0.78 µF
(1.1 to 3.2999) mF (0 to 6) Hz 0.26 % + 2.3 µF
(3.3 to 10.9999) mF (0 to 2) Hz 0.26 % + 7.8 µF
(11 to 32.9999) mF (0 to 0.6) Hz 0.54 % + 23 µF
(33 to 110) mF (0 to 0.2) Hz 0.78 % + 78 µF | ||
| 57 | - | capacitorsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 57 of 79
Capacitance Measure & Generate
(DC Charge)
Capacitance Equivalent Frequency (±) CMC 2, 3, 4, 13 Comments
1 nF
(0.08 to 6) Hz Ramp
Rate V/Vs
520 µF/F
Fluke 8588A meter
calibrations & station
calibration
2 nF 670 µF/F
10 nF 290 µF/F
20 nF 180 µF/F
100 nF 180 µF/F
200 nF 84 µF/F
1 µF 250 µF/F
2 µF 230 µF/F
10 µF 240 µF/F
20 µF 250 µF/F
100 µF 250 µF/F
200 µF 250 µF/F
1 mF 250 µF/F
2 mF 250 µF/F
10 mF 260 µF/F
20 mF 250 µF/F
50 mF 250 µF/F
100 mF 250 µF/F
Standard capacitors / Andeen 2500 / characterized Fluke 5520A / transfer meter | 0.08 to 6 Hz |
| 58 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 58 of 79
Capacitance Measure
Capacitance Frequency ( ±) CMC2, 5, 13, 14
(100 to 399.9) pF 5 kHz 0.45 %
(100 to 399.9) pF
1 kHz
0.25 %
(0.4 to 1.09) nF 0.17x + 0.28 %
(1.1 to 329.999) nF 0. 0.05 %
(0.33 to 32.999) µF 100 Hz 0.050 %
(33 to 109.9) µF 50 Hz 0.050 %
(110 to 329.999) µF 40 Hz 0.000 29x + -0.0087 %
(0.33 to 1.09) mF 20 Hz 0.000 68x + 0.000 97 %
1.09 mF 15 Hz 0.050 %
(1.1 to 3.299) mF 6 Hz 0.050 %
(3.3 to 10.9) mF 2 Hz 0.050 %
(11 to 32.999) mF 600 mHz 0.053%
(33 to 110) mF 200 mHz 0.000 47x + 0.065 %
Comments Calibration of Fluke 55XX series calibrators with
Hioki IM3533 LCR meter | ||
| 59 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 59 of 79
Capacitance Generate (Fixed Points)
Capacitance Frequency ( ±) CMC2, 4, 5, 13 Comments
5 pF
10 MHz
0.18 pF
Fluke 55XX/
Fluke 9500/Hioki
IM3533/ PM630X
Calibrators using artifact
capacitors
20 pF
0.35 pF
29 pF
50 pF 0.70 pF
20 pF
1 MHz
0.16 pF
70 pF
0.50 pF
90 pF
1.0 pF
100 Hz to 10 MHz
0.035 %
10 pF 0.015 %
100 pF 0.012 %
1000 pF 0.035 %
(1, 10, 100, 200,
500, 1000) nF 1 kHz 50 µF/F Standard capacitors
Inductance Generate
Fixed Point Frequency
(±) CMC2, 4, 13
Comments
1 mH (100 to 400) Hz 110 µH/H
General Radio 1482
1 mH 1 kHz 71 µH/H
100 mH (100 to 400) Hz 100 µH/H
100 mH 1 kHz 71 µH/H
10 H (100 to 200) Hz 300 µH/H
10 H 400 Hz 250 µH/H
10 H 1 kHz 78 µH/H
Comments Calibration of Fluke PM63XX & Hioki IM3533 LCR meters | 100 to 10000000 Hz |
| 60 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 60 of 79
Electrical Simulation of Thermocouples Generate & Measure
Thermocouple Type Range ( ±) CMC2
Type J
(-210 to -100) °C 0.10 °C
(-100 to 800) °C 0.05 °C
(800 to 1200) °C 0.06 °C
Type K
(-200 to -100) °C 0.11 °C
(-100 to 500) °C 0.06 °C
(500 to 800) °C 0.07 °C
(800 to 1372) °C 0.08 °C
Comments Calibration of handheld Fluke thermometers & process calibrators
Oscilloscopes
Parameter Range ( ±) CMC2, 4, 5, 6 Comments
Voltage p-p (50 Ω)
(10 Hz to 10 kHz) (0.050 to 0.75) V 0.1 % + 20 µV
Fluke 9500
scope calibrator
Voltage p-p (1 MΩ) (0.012 to 60) V 0.078 % + 40 µV
Fluke
5520A/SC1100
Voltage DC (0.006 to 300) V 0.050 % + 50 µV Fluke
5520A/SC1100
Timing Accuracy 10 ns to 100 µs 60 µs/s Fluke 9500
scope calibrator
Comments Calibration of Tektronix DSA8300 & Fluke scope meters | ||
| 61 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 61 of 79
AC Power Measure
Frequency Voltage Current (A) Equivalent
Power (W)
(±) CMC2, 4, 9, 13 (μW/W)
PF 1.0, 0° PF 0.5, 60°
50 Hz
&
60 Hz
115 V
0.250 29
35 51 0.375 43
1.5 173
3.0 345 39 54
15.0 1725
41 55 30.0 3450
50.0 5750
230 V
0.250 58 36
51 0.375 86
35
1.5 345
3.0 690 39 54
15.0 3450
41 55 30.0 6900
50.0 11 500
Comments Fluke 61XXA calibration system calibration of Fluke 61XXA
calibrators
(Table 1 of 2)
Dips & Swells Measure
Frequency Range Level Interval (s) (±) CMC2, 4, 13
(μV/V)
50 Hz
&
60 Hz
90 V
7 V
0.5
190
70 V 35
90 V 34
7 V
60 26 70 V
90 V
180 V
12 V
0.5
290
115 V 38 180 V
12 V 60 42
115 V 22
Comments Fluke 61XXA calibration system calib ration of Fluke 61XXA calibrators | ||
| 62 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 62 of 79
(Table 2 of 2)
Dips & Swells Measure
Frequency Range Level Interval (s) (±) CMC2, 4, 13
(μV/V)
50 Hz
&
60 Hz
180 V 180 V 60 22
360 V
23 V
0.5
290
230 V 32 360 V
23 V
60
38
230 V 24 360 V
10 A
0.5 A
0.5
340
5.0 A 45
10.0 A 38
0.5 A
60 220 5.0 A
10.0 A 35
Comments Fluke 61XXA calibration system calibration of Fluke 61XXA calibrators
II. Electrical – RF/Microwave
RF Power Measure
Range
Frequency
(±) CMC2, 4, 5
Comments
1 mW 50 MHz 0.35 %
Tegam 1830 power
meter w/ HP 478H76
power sensor
Comments
Fluke internal calibration of RF power meter reference output | ||
| 63 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 63 of 79
Voltage Standing Wave Ratio (VSWR)
Parameter Frequency ( ±) CMC2, 4 Comments
VSWR of 1:1 to
1:1.4, Source
Output
Up to +13 dBm
50 Ω
(1 to 9.9) MHz 0.037 dB
86205A/FSU26
10 MHz to 1 GHz 0.028 dB
(1 to 1.7) GHz 0.037 dB
(1.7 to 2) GHz 0.047 dB
(2 to 2.5) GHz 0.064 dB
(2.5 to 3) GHz 0.10 dB
(3 to 3.6) GHz 0.18 dB
(3.6 to 4) GHz 0.21 dB
VSWR of 1:1 to
1:1.4, Source
Output
Up to +7 dBm
75 Ω
(1 to 49.9) MHz 0.043 dB
86207A/FSU26
50 MHz to 1 GHz 0.036 dB
(1 to 1.3) GHz 0.041 dB
(1.3 to 2) GHz 0.067 dB
VSWR of 1:1 to
1:2.4, Source
Output
Up to +13 dBm
2.92 mm
(2.5 to 5) GHz 0.26 dB
SC8233/FSU26
(5 to 11) GHz 0.42 dB
(11 to 20) GHz 0.42 dB
(20 to 27) GHz 0.65 dB
Comments Calibration station for Fluke 96XXX series RF reference sources | ||
| 64 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 64 of 79
(Table 1 of 3)
RF Flatness Measure, 50 Ω Level Sine (±) CMC2, 4, 8, 12
Frequency (24 to 20)
dBm
(20 to 0)
dBm
(0 to -10)
dBm
(-10 to -20)
dBm
(-20 to -30)
dBm
(-30 to -40)
dBm
1000 Hz
0.0025 dB 0.0025 dB 0.0025 dB
0.0027 dB
0.0032 dB 0.0042 dB 20 kHz
75 kHz 0.0032 dB
100 kHz 0.0026 dB 0.0026 dB 0.0027 dB 0.0033 dB 0.0040 dB 0.0048 dB
300 kHz
0.026 dB
0.022 dB
0.026 dB 0.026 dB
0.022 dB 0.022 dB
1 MHz
10 MHz
20 MHz
100 MHz
0.026 dB
0.026 dB
125 MHz
0.031 dB 0.031 dB
0.031 dB
300 MHz
0.031 dB 0.031 dB 750 MHz
1 GHz 0.035 dB 0.035 dB
1.4 GHz
0.048 dB
0.061 dB 0.061 dB 0.057 dB 0.057 dB
2 GHz 0.066 dB 0.066 dB 0.061 dB 0.061 dB
2.5 GHz
0.061 dB 0.092 dB 0.092 dB 0.092 dB 0.092 dB
3 GHz
3.5 GHz
0.074 dB
0.12 dB 0.12 dB 0.12 dB 0.12 dB
4 GHz 0.13 dB 0.13 dB 0.13 dB 0.13 dB
Comments Calibration station for Fluke 96XXX series RF reference sources | ||
| 65 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 65 of 79
(Table 2 of 3)
RF Flatness Measure, 50 Ω Level Sine (±) CMC2, 4, 8, 12
Frequency (-40 to -48)
dBm
(-48 to -58)
dBm
(-58 to -68)
dBm
(-68 to -78)
dBm
(-78 to -88)
dBm
1000 Hz
0.0044 dB
20 kHz
0.024 dB
75 kHz
100 kHz 0.0057 dB 0.019 dB 0.035 dB 0.038 dB 0.099 dB
300 kHz
0.026 dB 0.032 dB
0.044 dB
0.040 dB
0.10 dB
1 MHz
10 MHz
0.037 dB
0.093 dB
20 MHz
0.063 dB
100 MHz
125 MHz
0.031 dB 0.036 dB
0.041 dB 0.043 dB 0.065 dB
300 MHz
750 MHz 0.054 dB 0.055 dB 0.069 dB
1 GHz 0.071 dB 0.072 dB 0.094 dB
1.4 GHz 0.057 dB 0.061 dB 0.10 dB 0.10 dB 0.12 dB
2 GHz 0.061 dB 0.066 dB 0.13 dB 0.13 dB 0.15 dB
2.5 GHz
0.092 dB 0.10 dB
0.15 dB 0.15 dB
0.18 dB
3 GHz 0.18 dB 0.18 dB
3.5 GHz 0.12 dB 0.13 dB 0.20 dB 0.20 dB 0.20 dB
4 GHz 0.13 dB 0.14 dB 0.21 dB 0.21 dB 0.21 dB
Comments Calibration station for Fluke 96XXX series RF reference sources | ||
| 66 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 66 of 79
(Table 3 of 3)
RF Flatness Measure, 50 Ω Level Sine (±) CMC2, 4, 8, 12
Frequency (-88 to -98) dBm (-98 to -108) dBm (-108 to -118) dBm (-118 to -128) dBm
100 kHz 0.14 dB 0.20 dB
0.18 dB 0.46 dB 300 kHz 0.10 dB
0.13 dB
1 MHz 0.077 dB
10 MHz
0.062 dB
0.11 dB 0.16 dB
0.20 dB 20 MHz
0.099 dB
0.15 dB 100 MHz
125 MHz
0.064 dB
0.10 dB 0.25 dB
300 MHz
0.19 dB 0.39 dB
0.47 dB 750 MHz 0.079 dB
1 GHz 0.096 dB 0.20 dB 0.40 dB
1.4 GHz 0.12 dB 0.22 dB 0.42 dB
0.48 dB
2 GHz 0.14 dB 0.24 dB
0.43 dB
2.5 GHz 0.17 dB
0.26 dB 0.49 dB
3 GHz 0.19 dB 0.45 dB
3.5 GHz 0.21 dB 0.29 dB 0.49 dB 0.55 dB
4 GHz 0.22 dB
Comments Calibration station for Fluke 96XXX series RF reference sources | ||
| 67 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 67 of 79
(Table 1 of 3)
RF Flatness Measure, 75 Ω Level Sine (±) CMC2, 4, 8, 12
Frequency (18 to 11)
dBm
(11 to 0)
dBm
(0 to -10)
dBm
(-10 to -20)
dBm
(-20 to -30)
dBm
(-30 to -40)
dBm
1000 Hz
0.0030 dB 0.0030 dB 0.0030 dB 0.0030 dB
0.0030 dB 0.0040 dB 20 kHz
75 kHz
100 kHz 0.0040 dB 0.0050 dB
300 kHz 0.064 dB 0.061 dB 0.061 dB 0.061 dB 0.061 dB 0.061 dB
1 MHz
0.055 dB 0.052 dB 0.052 dB 0.052 dB
0.057 dB 0.057 dB
10 MHz
20 MHz
0.059 dB 0.057 dB 0.057 dB 0.057 dB
100 MHz
125 MHz
0.064 dB 0.061 dB 0.061 dB 0.061 dB 0.061 dB 0.061 dB
300 MHz
750 MHz 0.077 dB 0.074 dB 0.074 dB 0.074 dB 0.074 dB 0.074 dB
1 GHz 0.087 dB 0.083 dB 0.083 dB 0.083 dB 0.083 dB 0.083 dB
1.4 GHz 0.12 dB
0.11 dB 0.11 dB 0.11 dB
0.11 dB 0.11 dB
2 GHz
0.12 dB 0.12 dB 2.5 GHz
0.12 dB 0.12 dB 0.12 dB
3 GHz
Comments Calibration station for Fluke 96XXX series RF reference sources | ||
| 68 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 68 of 79
(Table 2 of 3)
RF Flatness Measure, 75 Ω Level Sine (±) CMC2, 4, 8, 12
Frequency (-40 to -43)
dBm
(-43 to -55)
dBm
(-55 to -65)
dBm
(-65 to -75)
dBm
(-75 to -85)
dBm
1000 Hz
0.0050 dB
20 kHz
0.048 dB 0.049 dB 75 kHz
100 kHz 0.050 dB 0.074 dB
300 kHz 0.048 dB 0.076 dB 0.077 dB 0.078 dB 0.094 dB
1 MHz
0.044 dB
0.073 dB 0.074 dB 0.075 dB 0.091 dB
10 MHz
20 MHz
0.048 dB
100 MHz
125 MHz
0.076 dB 0.077 dB 0.078 dB 0.094 dB
300 MHz
750 MHz 0.066 dB 0.088 dB 0.089 dB 0.090 dB 0.10 dB
1 GHz 0.074 dB 0.096 dB 0.097 dB 0.098 dB 0.11 dB
1.4 GHz
0.11 dB
0.14 dB 0.14 dB 0.14 dB
0.16 dB
2 GHz
0.17 dB
2.5 GHz
0.12 dB
3 GHz
Comments Calibration station for Fluke 96XXX series RF reference sources | ||
| 69 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 69 of 79
(Table 3 of 3)
RF Flatness Measure, 75 Ω Level Sine (±) CMC2, 4, 8, 12
Frequency (-85 to -95) dBm (-95 to -105) dBm (-105 to -115) dBm (-115 to -125) dBm
100 kHz 0.076 dB 0.13 dB
0.27 dB 0.27 dB
300 kHz 0.096 dB 0.15 dB
1 MHz
0.094 dB 0.14 dB
10 MHz
20 MHz
100 MHz
125 MHz
0.096 dB
0.15 dB
300 MHz 0.22 dB
0.45 dB 0.45 dB 750 MHz
0.11 dB 0.23 dB
1 GHz
1.4 GHz
0.17 dB 0.25 dB 0.47 dB 0.47 dB
2 GHz
2.5 GHz
3 GHz
Comments Calibration station for Fluke 96XXX series RF reference sources | ||
| 70 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 70 of 79
(Table 1 of 4)
RF Flatness Measure, 50 Ω Level Sine,
2.92 mm Microwave Output (±) CMC2, 4, 8, 12
Frequency (24 to 18) dBm (18 to 0) dBm (0 to -10) dBm (-10 to -20)
dBm
(-20 to -30)
dBm
1 kHz
0.0048 dB 0.0048 dB 0.0048 dB 0.023 dB 0.023 dB 20 kHz
100 kHz
300 kHz
0.094 dB 0.087 dB 0.094 dB 0.095 dB 0.096 dB
1 MHz
10 MHz
20 MHz
100 MHz
125 MHz
0.099 dB 0.092 dB 0.098 dB 0.099 dB 0.10 dB
300 MHz
750 MHz
0.11 dB
0.095 dB
0.11 dB 0.11 dB 0.11 dB 1 GHz
1.4 GHz 0.096 dB
2 GHz
0.12 dB 0.10 dB 0.12 dB 0.12 dB 0.12 dB
2.5 GHz
3 GHz
3.5 GHz
4 GHz
5 GHz
6 GHz
7 GHz
0.14 dB 0.12 dB 0.14 dB
0.14 dB 0.14 dB 8 GHz
9 GHz
10 GHz
0.15 dB 0.15 dB
11 GHz
Comments Fluke 96270A RF reference source | ||
| 71 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 71 of 79
(Table 2 of 4)
RF Flatness Measure, 50 Ω Level Sine,
2.92 mm Microwave Output (±) CMC2, 4, 8, 12
Frequency (24 to 18) dBm (18 to 0) dBm (0 to -10) dBm (-10 to -20)
dBm
(-20 to -30)
dBm
12 GHz 0.14 dB 0.12 dB 0.14 dB 0.16 dB 0.16 dB
13 GHz
0.19 dB
0.17 dB
0.20 dB
0.21 dB 0.21 dB 14 GHz
15 GHz
16 GHz
0.20 dB
0.22 dB
0.22 dB 17 GHz
18 GHz
0.21 dB
19 GHz
0.18 dB
0.23 dB
20 GHz 0.23 dB
21 GHz
0.25 dB 0.25 dB
22 GHz
23 GHz
0.21 dB
0.22 dB
0.26 dB 0.26 dB
24 GHz 0.27 dB 0.27 dB
25 GHz 0.19 dB 0.23 dB
0.28 dB 0.28 dB 26 GHz
0.22 dB 0.20 dB 0.24 dB
26.5 GHz
Comments Fluke 96270A RF reference source | ||
| 72 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 72 of 79
(Table 3 of 4)
RF Flatness Measure, 50 Ω Level Sine,
2.92 mm Microwave Output (±) CMC2, 4, 8, 12
Frequency (-30 to -40)
dBm
(-40 to -50)
dBm
(-50 to -60)
dBm
(-60 to -70)
dBm
(-70 to -80)
dBm
(-80 to -90)
dBm
1 kHz
0.023 dB 0.047 dB
20 kHz 0.11 dB 0.13 dB
0.15 dB 0.15 dB
100 kHz 0.080 dB 0.082 dB
300 kHz
0.097 dB 0.10 dB 0.11 dB
0.12 dB 0.13 dB
0.13 dB
1 MHz
10 MHz
20 MHz
100 MHz
125 MHz
0.10 dB
0.12 dB 0.12 dB
300 MHz
750 MHz
0.11 dB 1 GHz
0.14 dB 1.4 GHz
2 GHz
0.12 dB 0.13 dB 0.13 dB 0.13 dB 0.14 dB
2.5 GHz
0.15 dB
3 GHz
3.5 GHz
4 GHz
5 GHz
6 GHz 0.13 dB 0.15 dB 0.15 dB 0.14 dB 0.15 dB
7 GHz
0.14 dB 0.16 dB
0.16 dB 0.16 dB
0.20 dB
0.19 dB
8 GHz
0.20 dB
9 GHz 0.17 dB 0.17 dB
Comments Fluke 96270A RF reference source | ||
| 73 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 73 of 79
(Table 4 of 4)
RF Flatness Measure, 50 Ω Level Sine,
2.92 mm Microwave Output (±) CMC2, 4, 8, 12
Frequency (-30 to -40)
dBm
(-40 to -50)
dBm
(-50 to -60)
dBm
(-60 to -70)
dBm
(-70 to -80)
dBm
(-80 to -90)
dBm
10 GHz
0.15 dB
0.17 dB 0.17 dB
0.17 dB
0.20 dB
0.20 dB
11 GHz
0.21 dB 0.21 dB
12 GHz 0.16 dB 0.18 dB
13 GHz
0.21 dB 0.25 dB
0.25 dB
0.22 dB
0.24 dB 14 GHz
0.28 dB 0.24 dB
15 GHz
0.28 dB 16 GHz
0.22 dB
0.28 dB
0.30 dB
0.27 dB 0.27 dB
17 GHz
18 GHz
0.46 dB
0.32 dB
0.30 dB
0.30 dB
19 GHz
0.23 dB
0.31 dB 0.31 dB
20 GHz
0.33 dB 0.54 dB 0.37 dB 0.37 dB
21 GHz
0.25 dB
22 GHz
23 GHz 0.26 dB
24 GHz 0.27 dB 0.44 dB
0.62 dB 0.54 dB 0.54 dB
25 GHz
0.28 dB 0.73 dB
0.49 dB
26 GHz
0.70 dB 0.91 dB 0.91 dB
26.5 GHz 0.62 dB
Comments Fluke 96270A RF reference source | ||
| 74 | - | NitrogenShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 74 of 79
III. Mechanical
Parameter
Range
(±) CMC2, 5
Comments
Gauge Pressure –
Measuring Instruments
(Pneumatic)
Nitrogen
(-100 to 0) kPa 0.0024 % + 5.2 Pa Ruska 7250i
(0 to 1875) Pa 0.0075 % + 100 mPa
Fluke 7250LP
differential7 (1875 to 2833) Pa 0.0090 % + 37 mPa
(2833 to 7500) Pa 0.0091 % + 14 mPa
(7.5 to 27.5) kPa
(27.5 to 55) kPa
0.0077 % + 1.4 Pa
0.0091 % + 0.41 Pa Ruska 7250xi
(55 to 82.7) kPa
(82.7 to 206.9) kPa
0.0024 % + 4.1 Pa
0.0056 % + 20 mPa Ruska 7250i
(206.8 to 248.2) kPa 25 Pa Fluke PM500-
BG250k
(248.2 to 344.7) kPa 34 Pa Fluke PM500-G700k
(344.7 to 689.4) kPa 0.01 % Fluke PM500-G700k
(689.4 to 3500) kPa 0.0092 % + 0.55 Pa Ruska 7250xi
(3.5 to 7) MPa 0.01 % Fluke PM500-BG7M
(7 to 10.3) MPa 0.01 % Fluke PM500-
BG10M
(10.3 to 13.8) MPa 0.0093 % + 0.13 kPa Ruska 7250i
(13.8 to 20) MPa 0.01 % Fluke PM500-
BG20M
(20 to 70) MPa 0.01 % Fluke PM630-A70M
Absolute Pressure –
Measuring Instruments
(Pneumatic)
Nitrogen
(0.7 to 82.7) kPa
(82.7 to 206.8) kPa
0.0025 % + 4.3 Pa
0.0056 % + 1.3 Pa Ruska 7250i
(206.8 to 344.7) kPa 0.027 kPa Fluke PM500-
BG250k
(344.7 to 441.3) kPa 0.036 kPa Fluke PM500-G700k
(441.3 to 786) kPa 0.01 % + 0.01 kPa Fluke PM500-G700k
(786 to 3500) kPa 0.0092 % + 14 Pa Ruska 7250xi
(3.5 to 7) MPa 0.01 % + 0.01 kPa Fluke PM500-BG7M
(7 to 10.3) MPa 0.01 % + 0.01 kPa Fluke PM500-
BG10M | See scope document |
| 75 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 75 of 79
IV. Thermodynamics
Parameter
Range ( ±) CMC2, 11 Comments
Temperature –
Measure & Measuring
Equipment
(PRT Calibration)
-50 °C
0.010 °C TPW
29.7646 °C MpGa
0.010 °C Super-thermometer
(1595A)/PRT reference
thermometer, TPW cell,
Ga cell, In cell, dry
wells
100 °C
156.5985 °C MpIn 0.012 °C
(100 to 500) °C 0.050 °C
Temperature –
Measuring Equipment
(Calibration of
Thermistors)
(0 to 100) °C 0.008 °C
Super-thermometer
(1595A)/PRT reference
thermometer, TPW cell,
liquid baths
Temperature –
Measuring Equipment
Fixed Points
0.0100 °C TPW 0.004 °C
TPW cell, Ga cell, In
cell
29.7646 °C MpGa 0.005 °C
156.5985 °C MpIn 0.006 °C
Temperature –
Measuring Equipment
Set Points
-60 °C 0.016 °C
Super-thermometer
(1595A) /PRT reference
thermometer, liquid
baths & dry wells
-50 °C, -40 °C 0.010 °C
-20 °C 0.018 °C
50 °C 0.014 °C
100 °C 0.012 °C
200 °C, 300 °C, 400 °C 0.042 °C
500 °C 0.046 °C
Temperature –
Measuring Equipment,
Thermocouples
(Type E, J, K, T)
(20 to 30) °C 0.035 °C Super-thermometer,
SPRT, liquid baths
Temperature –
Measuring Equipment,
Handheld Meter
(-10 to 24.9) °C
(25 to 55) °C
0.75 °C
0.077 °C Environmental chamber
Comments Calibration station for Fluke temperature probes & meters | ||
| 76 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 76 of 79
Humidity – Measuring Equipment
Parameter Range ( ±) CMC2, 11 Comments
% Relative
Humidity
(15 to 90) % RH
0.53 % RH
Thunder Scientific 2500ST
environmental chamber
Infrared Radiation – Measure
Wavelength [λ] Range ( ±) CMC2, 11 Comments
(8 to 14) µm
(233 to 303) K -2.0 x 10 -3 Tm + 0.81 K
Heitronics TRT IV (303 to 1233) K 1.1 x 10 -3 Tm - 0.14 K
(1233 to 1773) K 2.1 x 10 -3 Tm - 1.4 K
3.9 µm (428 to 1233) K 0.20 x 10 -3 Tm + 0.65 K Heitronics TRT II
2.4 µm 343 K
(423 to 2073) K
1.5 x 10-3 Tm
1.8 x 10-3 Tm - 0.3 K
Endurance E3MH
1.6 µm (523 to 2523) K 1.8 x 10 -3 Tm - 0.2 K
Endurance E2MH,
Endurance E3MH
1.0 µm (723 to 3273) K 1.9 x 10 -3 Tm - 0.2 K Endurance E1MH,
Endurance E2MH
Where Tm represents the measurement temperature [K] Fluke IR calibration station
Infrared Radiation – Measuring Equipment
Wavelength [λ] Range ( ±) CMC2, 11 Comments
(8 to 14) µm
(233 to 303) K -2.1 x 10 -3 Tm + 0.82 K
IR cavity, Heitronics TRT IV (303 to 1233) K 0.99 x 10 -3 Tm - 0.13 K
(1233 to 1773) K 2.2 x 10 -3 Tm - 1.6 K
3.9 µm (428 to 1233) K 0.80 x 10 -3 Tm + 0.19 K IR cavity, Heitronics TRT II
2.4 µm 343 K
(423 to 2073) K
2.5 x 10-3 Tm
1.9 x 10-3 Tm - 0.2 K IR cavity, Endurance E3MH
1.6 µm (523 to 2523) K 1.9 x 10 -3 Tm - 0.2 K IR cavity, Endurance E2MH,
Endurance E3MH
1.0 µm (723 to 3273) K 2.1 x 10 -3 Tm - 0.4 K IR cavity, Endurance E1MH,
Endurance E2MH
Where Tm represents the measurement temperature [K] Fluke IR calibration station | ||
| 77 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 77 of 79
V. Rise Time
Parameter Range ( ±) CMC2, 11 Comments
Rise/Fall Time –
Measure
(4 mV to 4 V)
23 ps to 2 ns 4 ps
Fluke 55XX & Fluke
95XX head calibration
stations
Rise Time –
Generate
(4 mV to 4 V)
10 ps to 25 ps 7.3 ps Tektronix fast step
generator
Comments Calibration of Tektronix 11801 or Tektronix DSA8300 digital sampling
oscilloscope
VI. Time & Frequency
Parameter Range ( ±) CMC2, 11 Comments
Frequency –
Generate & Measure (1, 5, 10) MHz 0.9 parts in 1012
Hz/Hz
GPS through FMAS
system from NIST &
Fluke 910R
Frequency –
Generate
1 mHz to 10 MHz 1.0 parts in 1010
Hz/Hz + 1 µHz GPS based 10 MHz
distributed signal &
Fluke 9640/HP 3325B
signal generators 10 MHz to 4.0 GHz 5.5 parts in 109 Hz/
Hz
Frequency –
Measure
1 mHz to 1.3 GHz 6.0 parts in 1012 Hz/Hz
+ 2.4 µHz GPS based 10 MHz
distributed signal &
Fluke 6680B counter (1.3 to 2.7) GHz 14 µHz
(3 to 26.5) GHz 110 parts in 1012
Hz/Hz
Spectrum analyzer
Comments Calibration station for Fluke Frequency counters & Fluke 96XXX | 0.023 to 2 ns |
| 78 | ASTM G-173 | - | See scope document |
| 79 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2166.01) Revised 12/19/2025 Page 79 of 79
2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3
Consensus Traceability based on extrapolation of measured values.
4 The uncertainties shown relate to voltages and frequencies that lie within ± 10 % of the specified values.
For intermediate points between the discrete unit pair s, the uncertainty will be the greatest of the 4
adjacent unit pairs, plus 10 %.
5 In the statement of CMC, ratios such as percent values are of reading, unless otherwise indicated in the
table.
6 The contributions from the “best existing device” are not included in the CMC claim for this parameter.
7 CMCs apply to negative equivalent pressure.
8 For intermediate Frequency points, the larger CMC from the adjacent Frequency points applies.
9 The laboratory does not offer commercial calibration service for this measurement parameter.
10 This scope meets A2LA’s P112 Flexible Scope Policy.
11 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
12 The uncertainties are applicable to the source am plitude measurement of the Fluke 96270A for the
fundamental, specified harmonic frequencies and RF Reference Source using a dedicated measurement
system. Uncertainties may also be reported for differences in level re ported as Attenuation, the
attenuation uncertainty will be the combined uncertain ties of the reference level and the uncertainty of
the final level.
13 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
14 In the statement of CMC, x is the measured value. | ||
| 80 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Eustis Co., Inc./Pyrocom CalibrationLynnwood, WA · ~18 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Robb Precision Tool ServicesLynnwood, WA · ~18 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - SeattleRedmond, WA · ~35 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Cascade Engineering ServicesRedmond, WA · ~36 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ThermetricsSeattle, WA · ~43 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.