FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
ISO/IEC 17025 directory · Standard series

EN 16911 Accredited Testing Labs in United Kingdom

EN 16911, all parts9 laboratories in United Kingdom are accredited by UKAS for at least one part of EN 16911. Each lab card shows which parts it holds. Most frequently tested analytes via this method in United Kingdom: Velocity. From the accredited scope text: “EN 16911-2, Environment Agency MID 16911-2 and other requirements of the Environment Agency (MCERTS) Performance Standard and BS EN 15259:2007 Stacks (East Kilbride, Altrincham, Cirencester and Romfor” “EN 16911-1:2013 & EA MID 16911-1 (Method QD019 using differential pressure device pitot tube method) Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1 C Velocity ISO 10780” “EN 16911-1:2013 & EA MID 16911-1 (W1 4/1 – using differential pressure device (pitot tube) method) (W1 4/56 – using differential pressure device (pitot tube) method) - Gravimat Procedure to meet requi” “EN 16911-2:2013, Environment Agency MID 16911- 2 and other requirements of the Environment Agency (MCERTS) Performance Standard and BS EN 15259:2007 EST Testing of Stack Emissions to Atmosphere (cont’”

Labs
5
Top analyte
Velocity4 labs
Primary AB
UKAS9 labs
Parts of this series

Accredited Labs

TUV SUD Limited Trading as TÜV SÜD National Engineering Laboratory & National Engineering

Glasgow, GB

HoldsPart 1
Scope

EN 16911-1:2013 & EA MID 16911-1 (WI/EM/962using differential pressure device (Pitot tube) method) Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1 B Carbon Dioxide* PD CEN/TS 17405:2020 (WI/

View lab

Technological Laboratory of Uruguay

Av. Italia 6201, C.P. 11500, Montevideo, Uruguay, Uruguay, GB

HoldsPart 1
Scope

EN 16911-1:2013 Site - MAM TOYS AND TOY PACKAGING Chemical Tests Migration of certain elements: Arsenic Barium Antimony Cadmium Chromium Lead Selenium Mercury PEC.ESPEC.024 based on Mercosur Standard NM-300- 3:20

View lab

Olfasense UK

Bristol, GB

HoldsPart 1
Scope

EN 16911-1:2013 & EA MID 16911-1 (Method QD019 using differential pressure device pitot tube method) Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1 C Velocity ISO 10780:1994 (QD019) by hot wire

View lab

CES Environmental Instruments

Staffordshire, GB

HoldsPart 1Part 2
Scope

EN 16911-1:2013 & EA MID 16911-1 (W1 4/1 – using differential pressure device (pitot tube) method) (W1 4/56 – using differential pressure device (pitot tube) method) - Gravimat Procedure to meet requirements of PD CEN TR 17078:201

View lab

Environmental Compliance

Pontypridd, GB

HoldsPart 1Part 2
Scope

EN 16911-1:2013 & EA MID 16911-1 (Method ECL/TPD/022A using differential pressure device (pitot tube) method) Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1 A, B Pressure, Temperature and Vel

View lab
Refine these results

This page is a fixed slice of the register: every EN 16911 scope we hold for United Kingdom. Search narrows it further by city, accreditation body, or a term from the scope text itself.

Search labs in United Kingdom

Top matrices for EN 16911 in United Kingdom

Top analytes for EN 16911 in United Kingdom

  • Velocity4
  • Carbon Monoxide1
  • Hydrogen Sulphide1
  • Particulate Matter1
  • Ammonia1

About ISO/IEC 17025 in United Kingdom

United Kingdom Accreditation Service (UKAS) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United Kingdom.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.

Related searches