Smithers MSE
Surrey, GB
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Smithers MSE Limited Issue No: 073 Issue date: 25 March 2025 Testing
15 laboratories in United Kingdom are accredited by UKAS under ISO/IEC 17025 to perform IEC 60068-2-30 testing. From the accredited scope text: “IEC 60068-2-30:1980 Humidity: 20 % to 98 % BS EN 60068-2-30:2005 Variants 1 and 2 RTCA/DO-160D:1997 Test chamber size: 2500 litre RTCA/DO-160E:2004 RTCA/DO-160F:2007 RTCA/DO-160G:2010” “IEC 60068-2-30:2005 Max chamber size: (Walk-In) IEC 68-2-56:1988 1.8 m x 2.4 m x 2.4 m (high) IEC 60068-2-78:2012 Test Cab” “IEC 60068-2-30:2005 IEC 60068-2-31:2008 IEC 60068-2-47:2005 IEC 60068-2-64:2008 IEC 60068-2-78:2013 (Withdrawn) NMI R137-1&2(2013) BS EN 17526:2021 (superceeded) BS EN 17526:2021+A1:2025 EN 17526:2021” “IEC 60068-2-30:2005 BS EN IEC 60068-2-78:2013 GB/T2423.4-2008EN”
Surrey, GB
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Smithers MSE Limited Issue No: 073 Issue date: 25 March 2025 Testing
Durham, GB
IEC 60068-2-30:2005 IEC 60068-2-78:2012 BS EN 60068-2-78:2013 BS EN 60068-2-30:2005 Test Db BS EN 60945:2002& IEC 60945:2002 , section 8.3 MIL-STD 810G Method 520 Para 235-236* *Excluding simultaneous vibration testing BS EN 50
Berkshire, GB
IEC 60068-2-30:2005 Max chamber size: (Walk-In) IEC 68-2-56:1988 1.8 m x 2.4 m x 2.4 m (high) IEC 60068-2-78:2012 Test Cab
Nottinghamshire, GB
IEC 60068-2-30: 2005 IEC 60068-2-78: 2012 Low Air Pressure Diameter 0.32 m x 0.42 m IEC 60068-2-13: 2021 Salt Mist 1.01 m x 0.64 m x 1.14 m IEC 60068-2-11:2021 EIA-364-26C DYNAMIC TESTING Vibration
Co Durham, GB
IEC 60068-2-30:2005 A Constant/Cyclic IEC 60068-2-78:2001 BS EN 60068-2-30:2005 Test Db Humidity range: BS EN 60068-2-78:2002 10 % rh to 98 % rh BS EN 60068-2-78:2013 (at temps > + 10 °C) BS EN 60945, section 8.3 Max
Worcestershire, GB
IEC 60068-2-30:1980 Temp range: IEC/EN 60068-2-30:2005 +20 °C to +100 °C IEC/EN 60068-2-78:2001 Humidity range: EN 50130-5:1999 40 % rh to 98 % rh EN 50130-5:2011 Max chamber size: BS 2011:Part 2.1Db:1981+A1 75
Northamptonshire, GB
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK 3C Test Ltd Issue No: 068 Issue date: 22 Aug
Suffolk, GB
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK Alphatech Limited Issue No: 023 Issue date: 27
Dorset, GB
Assessment Manager: DP4 Page 1 of 2 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 28772 Accredited to ISO/IEC 17025:2017 Rivencore G
West Midlands, GB
IEC 60068-2-30:1980 Humidity: 20 % to 98 % BS EN 60068-2-30:2005 Variants 1 and 2 RTCA/DO-160D:1997 Test chamber size: 2500 litre RTCA/DO-160E:2004 RTCA/DO-160F:2007 RTCA/DO-160G:2010
Post Box 169, Plot No. F-373 - 375, Rilco Bhamashah Industrial Area, Kaladwas, Udaipur 313 003, India, GB
IEC 60068-2-30:2005 IEC 60068-2-31:2008 IEC 60068-2-47:2005 IEC 60068-2-64:2008 IEC 60068-2-78:2013 (Withdrawn) NMI R137-1&2(2013) BS EN 17526:2021 (superceeded) BS EN 17526:2021+A1:2025 EN 17526:2021+A1:2025 BS EN 1359:1
Rhymney, GB
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK Rhymney Test Equipment Limited Issue No: 004 Iss
Devon, GB
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Product Assessment and Reliability Centre Limited T/A PARC Issue No: 037
Ellesmere Port, GB
IEC 60068-2-30:2005 BS EN IEC 60068-2-78:2013 GB/T2423.4-2008EN
Essex, GB
IEC 60068-2-30:2005 IP Damp Heat, steady state Temp range: + 5 °C to + 180 °C Humidity range: 10 % rh to 98 % rh Max chamber size: 0.75 m x 0.75 m x 0.75 m Humidity range: 10 %rh to 93 %rh Max chamber size:
This page is a fixed slice of the register: every IEC 60068-2-30 scope we hold for United Kingdom. Search narrows it further by city, accreditation body, or a term from the scope text itself.
Search labs in United KingdomUnited Kingdom Accreditation Service (UKAS) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United Kingdom.
ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.