Element Materials Technology - Malvern
Malvern, GB
IEC 61000-4-4:2012; EN/IEC 61000-4-4
9 laboratories in United Kingdom are accredited to perform IEC 61000-4-4 testing, 7 of them by UKAS. We don't know yet whether 2 of them take outside work. From the accredited scope text: “IEC 61000-4-4:2012; EN/IEC 61000-4-4” “IEC 61000-4-4:2012; EN/IEC 61000-4-4 EMC – Commercial Immunity: Surge EN/IEC 61000-4-5:2005; EN/IEC 61000-4-5 EMC – Commercial Immunity: Conducted Immunity EN/IEC 61000-4-6:2013; EN/IEC 61000-4-6 EMC” “IEC 61000-4-4:2012 Transient Immunity 0.25 kV to 5 kV 5 kHz / 100 kHz 3 – 690 Vac / 3x 32 A 1.2.3 – Voltage Surge Immunity IEC 61000-4-5:2014 0.25 kV to 5 kV IEC 61000-4-5:2017 1.2 / 50 (8/20) µs 2 Ω” “IEC 61000-4-4:2004 Ed 2.0 5 ns rise time 10 ns duration EN 55020:2002 G 15 or 75 ms burst duration Documented Element Procedure A,B,C,E STP-1009 Electrical Fast Burst Transient 10.1.13 Surge Immunity”
Malvern, GB
IEC 61000-4-4:2012; EN/IEC 61000-4-4
Worcestershire, GB
IEC 61000-4-4:2004 Ed 2.0 5 ns rise time 10 ns duration EN 55020:2002 G 15 or 75 ms burst duration Documented Element Procedure A,B,C,E STP-1009 Electrical Fast Burst Transient 10.1.13 Surge
Castleford, GB
IEC 61000-4-4:1995 + A1 + A2 B, C, G (B, C, G) IEC 61000-4-4:2004 B, C, G EN 61000-4-4:2004 B, C, G IEC 61000-4-4:2004 + A1 B, C, G EN 61000-4-4:2004 + A1 B, C, G EN 61000-4-4:2012 B, C, G
Northamptonshire, GB
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK 3C Test Ltd Issue No: 068 Issue date: 22 Aug
Watford, GB
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK BRE GLOBAL LIMITED Incorporating LPC Testing, BRE Tes
Kingston upon Hull, GB
IEC 61000-4-4:2012; EN/IEC 61000-4-4 EMC – Commercial Immunity: Surge EN/IEC 61000-4-5:2005; EN/IEC 61000-4-5 EMC – Commercial Immunity: Conducted Immunity EN/IEC 61000-4-6:2013; EN/IEC 61000-4-6 EMC – Commercial Immunity: Power
Cambridge, GB
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK dB Technology (Cambridge) Limited Issue No: 010
Hampshire, GB
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK Samsung Electronics Quality Assurance Lab Issue No
Cheshire, GB
IEC 61000-4-4:2012 Transient Immunity 0.25 kV to 5 kV 5 kHz / 100 kHz 3 – 690 Vac / 3x 32 A 1.2.3 – Voltage Surge Immunity IEC 61000-4-5:2014 0.25 kV to 5 kV IEC 61000-4-5:2017 1.2 / 50 (8/20) µs 2 Ω /
United Kingdom Accreditation Service (UKAS) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United Kingdom.
ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.