ISO 9513; Gage blocks, extensometer calibrator; uncertainties listed in displacement Gage blocks Caliper Micrometers³ – Up to 6 in (> 6 to 20) in (71 + 0.6R) µin (200 + 0.6R) µin Gage blocks
6 laboratories in United States are accredited by A2LA under ISO/IEC 17025 to perform ISO 9513 testing. From the accredited scope text: “ISO 9513 ASTM E2309 Using precision micrometer system or linear precision scale Gage blocks Testing Machine Crosshead Speed 3 – Measure Displacement Time (0.002 to 50) in/min -- 37 μin 0.0060 s ASTM E” “ISO 9513; Gage blocks, extensometer calibrator; uncertainties listed in displacement Gage blocks Caliper Micrometers³ – Up to 6 in (> 6 to 20) in (71 + 0.6R) µin (200 + 0.6R) µin Gage blocks” “ISO 9513 Digital caliper Heidenhain glass scale Displacement 3 – Measure (0.001 to 1.0) in (1.0 to 40) in 0.000 062 in 0.0017 in ASTM E 2309 Heidenhain length gages Morehouse readout linear measuremen” “ISO 9513 Extensometer calibrator Laser interferometer Extensometer calibrator (excluding ASTM E399) Optical & extensometer calibrator Caliper North America, Japan Norden North America, Japan MTS Lengt”
Naperville, IL, US
ISO 9513; Gage blocks, extensometer calibrator; uncertainties listed in displacement Gage blocks Caliper Micrometers³ – Up to 6 in (> 6 to 20) in (71 + 0.6R) µin (200 + 0.6R) µin Gage blocks
Chattanooga, TN, US
ISO 9513 Digital caliper Heidenhain glass scale Displacement 3 – Measure (0.001 to 1.0) in (1.0 to 40) in 0.000 062 in 0.0017 in ASTM E 2309 Heidenhain length gages Morehouse readout linear
Union, NJ, US
ISO 9513 ASTM E2309 Using precision micrometer system or linear precision scale Gage blocks Testing Machine Crosshead Speed 3 – Measure Displacement Time (0.002 to 50) in/min -- 37 μ
Riverview, MI, US
ISO 9513 using digital high accuracy length scale Scales & Balances 3 (0.01 to 1000) lbf 4.5 g to 454 kg 0.01 % + 0.6R Master dead weights ASTM E898 Torque 3 – Measuring Equipment (0.1 to 150) lbf∙ft (0.136 t
Eden Prairie, MN, US
ISO 9513 Extensometer calibrator Laser interferometer Extensometer calibrator (excluding ASTM E399) Optical & extensometer calibrator Caliper North America, Japan Norden North America, Japan
Suite E Addison, IL, US
Parameter/Equipment Range CMC2, 4, 7 () Comments Optical Comparators 3 – Linear Magnification Angle Up to 12 in Up to 100x (15,30,45,60,90, 120,150,180,270,360) deg (120 + 3.8L + 0.6R)
This page is a fixed slice of the register: every ISO 9513 scope we hold for United States. Search narrows it further by city, accreditation body, or a term from the scope text itself.
Search labs in United StatesAmerican Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.
ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.