EN 16911-1 Accredited Testing Labs Worldwide
15 accredited laboratories in 4 countries hold EN 16911-1 in their ISO/IEC 17025 scope. Primary accreditors include Deutsche Akkreditierungsstelle, United Kingdom Accreditation Service. In the register, EN 16911-1 scope entries most often cover Ammonia, Carbon Monoxide, Dust Concentration in Ambient air, Water, Stack emissions to atmosphere.
Available in 4 Countries
Top matrices for EN 16911-1
Top analytes for EN 16911-1
- Ammonia (1)
- Carbon Monoxide (1)
- Dust Concentration (1)
- Particulate Matter (1)
- Siliciumdioxid (1)
- Total Gaseous Organic Carbon (Toc/Voc) (1)
- Total Particulate Matter (1)
Sample labs
EN 16911-1:2013-06 DIN EN 16911-2:2013-06 Volumenstrom DIN EN 16911-1:2013-06 DIN EN 16911-2:2013-06
EN 16911-1:2013 & EA MID 16911-1 (WI/EM/962using differential pressure device (Pitot tube) method) Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1 B Carbon Dioxide* PD CEN/TS 17405:2020 (WI/
Prüfbereich Gruppe I.1: Ermittlung der Emissionen (Luft) §§ 26, 28 BImSchG und entsprechende Messaufgaben nach Verordnungen zur Durchführung des BImSchG Komponente Norm / Richtlinie / Technische Regel SRM Bemerkung Standort Silic
EN 16911-1. Anemometer 0.1-25m/s Industrial Fumes & Mixtures L & S type pitots, Anemometer EN 16911-1:2013 / SOP 2005 Determination of Carbon Dioxide CO2 0.1 to 25% Industrial Fumes & Mixtures NDIR CEN/ TS 17045: 2020/ SOP 2045
Edition 7, 09/12/2025 the requirements of BS EN 15259:2007 Sampling and On-Site Analysis-Determination of Pressure Pressure 0 – 8000 pa Industrial Fumes & Mixtures L & S Type Pitots SOP 2007 and EN 16911-1:2013
EN 16911-1:2013-06 DIN EN 16911-2:2013-06 Volumenstrom DIN EN 16911-1:2013-06 DIN EN 16911-2:2013-06 Sauerstoff DIN EN 14789:2017-05 Wasserdampf DIN EN 14790:2017-05 Prüfung der Funktionstüchtigkeit DIN EN 14181:2015-02 V
Prüfbereich Gruppe I.2: Ermittlung der Emissionen (Luft) nach Nr. I.1 und Messaufgaben, die eine spezielle gerätetechnische Ausstattung und spezielle Erfahrungen des fachkundigen Personals erfordern Komponente Norm / Richtlinie / Tech
EN 16911-1:2013 Site - MAM TOYS AND TOY PACKAGING Chemical Tests Migration of certain elements: Arsenic Barium Antimony Cadmium Chromium Lead Selenium Mercury PEC.ESPEC.024 based on Mercosur Standard NM-300- 3:20
EN 16911-1:2013 & EA MID 16911-1 (Method QD019 using differential pressure device pitot tube method) Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1 C Velocity ISO 10780:1994 (QD019) by hot wire
EN 16911-1:2013 & EA MID 16911-1 (W1 4/1 – using differential pressure device (pitot tube) method) (W1 4/56 – using differential pressure device (pitot tube) method) - Gravimat Procedure to meet requirements of PD CEN TR 17078:201
Prüfbereich Gruppe II.1: Überprüfung des ordnungsgemäßen Einbaus und der Fun ktion sowie Kalibrierung kontinuierlich arbeitender Emissionsmesseinrichtungen Überprüfungen und Kalibrierungen von Messeinrichtun gen an Anlagen, die eine ger
EN 16911-1:2013-07 CEN/TR 17078:2017 Strumień objętości gazu dla ciśnień dynamicznych > 5 Pa Metoda spiętrzenia Prędkość Zakres: (0,4 – 15) m/s Metoda termoanemometryczna PN-Z-04030-7:1994 Pobieranie próbek do oznaczania stężenia
Prüfbereich Gruppe II.1: Überprüfung des ordnungsgemäßen Einbaus und der Funktion sowie Kalibrierung kontinuierlich arbeitender Emissionsmesseinrichtungen Überprüfungen und Kalibrierungen von Messeinrichtungen an Anlagen, die eine geräte
Kennung Sp Spezielle Probenahme von Stoffen, die einen besonderen Aufwand bei der Probenahme oder Analyse erfordern Probenahmeverfahren zur Bestimmung der Einzelisomere von PCDD/PCDF DIN EN 1948 -1:2006 -06 Düsseldorf Probenahm
EN 16911-1:2013 & EA MID 16911-1 (Method ECL/TPD/022A using differential pressure device (pitot tube) method) Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1 A, B Pressure, Temperature and Vel