Registers refreshed 2026-11-20.See refresh dates

EN 16911 Accredited Testing Labs Worldwide

EN 16911, all parts. Each lab card shows which parts it holds.

Parts of this series

37 accredited laboratories in 5 countries hold EN 16911 in their accredited scope. We don't know yet whether 10 of them take outside work. Primary accreditors include Deutsche Akkreditierungsstelle, United Kingdom Accreditation Service, Entidad Nacional de Acreditación.

Total labs
37
Countries
5

Available in 5 Countries

Sample labs

SGS TECNOS, S.A. (Unipersonal)
Madrid, ES
Holds: Part 1 · Part 2

EN 16911-2 UNE-EN 14884 I II. Emisiones de fuentes estacionarias / Emissions of stationary sources TOMA DE MUESTRAS / SAMPLING NORMA/PROCEDIMIENTO DE ENSAYO METHOD/STANDARD OPERATING PROCEDURE CÓDIGO CODE Emisiones de fuent

Institut für Umweltschutz und Agrikulturchemie Feldbaum GmbH & Co. Kommanditgesellschaft
Velbert, DE
Holds: Part 1 · Part 2

EN 16911-1:2013-06 DIN EN 16911-2:2013-06 Volumenstrom DIN EN 16911-1:2013-06 DIN EN 16911-2:2013-06

Element Materials Technology Environmental UK Limited trading as Element
Stockport, GB
Holds: Part 2

EN 16911-2:2013, Environment Agency MID 16911- 2 and other requirements of the Environment Agency (MCERTS) Performance Standard and BS EN 15259:2007 EST Testing of Stack Emissions to Atmosphere (cont’d) Sampling with subsequent

TUV SUD Limited Trading as TÜV SÜD National Engineering Laboratory & National Engineering
Glasgow, GB
Holds: Part 1

EN 16911-1:2013 & EA MID 16911-1 (WI/EM/962using differential pressure device (Pitot tube) method) Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1 B Carbon Dioxide* PD CEN/TS 17405:2020 (WI/

TÜV RHEINLAND IBERICA INSPECTION, CERTIFICATION & TESTING
El Prat de Llobregat, ES
Holds: Part 1

EN 16911-1 UNE 77225 Un método interno se considera que está basado en métodos normalizados cuando su validez y su adecuación al uso se han demostrado por referencia a dicho método normalizado y en ningún caso implica que ENAC consider

ALS Germany
Altenberge, DE
Holds: Part 1 · Part 2

EN 16911 -1 2013-06 DIN EN 16911-2 2013-06 BE (PN), BO (PN)

AUDITORES DE ENERGIA Y MEDIO AMBIENTE
Castellón de la Plana, ES
Holds: Part 1

EN 16911-1 AE/IT30/PC/10 Método interno basado en: UNE-EN 77225 I Código Validación Electrónica: nU62B63a8Gv655v5J4 La acreditación mantiene su vigencia hasta notificación en contra. La presente acreditación está sujeta a modifi

Air Scientific
Dublin 1, IE
Holds: Part 1

EN 16911-1. Anemometer 0.1-25m/s Industrial Fumes & Mixtures L & S type pitots, Anemometer EN 16911-1:2013 / SOP 2005 Determination of Carbon Dioxide CO2 0.1 to 25% Industrial Fumes & Mixtures NDIR CEN/ TS 17045: 2020/ SOP 2045

TESMO Sp. z o.o.
Warszawa, PL
Holds: Part not stated on the certificate

EN 16911:2013-07 Pobieranie próbek pyłu do badań stężenia pyłu PN-Z-04030-7:1994 Stężenie pyłu Zakres: (0,001 – 100) g/m3 Metoda grawimetryczna PN-Z-04030-7:1994 Emisja pyłu (z obliczeń) Pobieranie próbek pyłu do badań s

Axis Environmental Services
Limerick, IE
Holds: Part 1

Edition 7, 09/12/2025 the requirements of BS EN 15259:2007 Sampling and On-Site Analysis-Determination of Pressure Pressure 0 – 8000 pa Industrial Fumes & Mixtures L & S Type Pitots SOP 2007 and EN 16911-1:2013

Umweltanalytik Saalfeld
Leutenberg, DE
Holds: Part 1 · Part 2

EN 16911-1:2013-06 DIN EN 16911-2:2013-06 Volumenstrom DIN EN 16911-1:2013-06 DIN EN 16911-2:2013-06 Sauerstoff DIN EN 14789:2017-05 Wasserdampf DIN EN 14790:2017-05 Prüfung der Funktionstüchtigkeit DIN EN 14181:2015-02 V

TÜV Rheinland Energy & Environment GmbH Messstelle für Immissionsschutz (Environmental Protection)
Köln, DE
Holds: Part 1 · Part 2

EN 16911 -1:2013 -06 DIN EN 16911-2:2013-06 ☒ K, Hi, Mz, Her, Lu, L, BM Volumenstrom DIN EN 16911 -1:2013 -06 DIN EN 16911-2:2013-06 ☒ K, Hi, Mz, Her, Lu, L, BM Sauerstoff DIN EN 14789:2017 -05 ☒ K, Hi, Mz, Her, Lu, L, BM Wass

SOCOTEC UK
Burton upon Trent, GB
Holds: Part 2

EN 16911-2, Environment Agency MID 16911-2 and other requirements of the Environment Agency (MCERTS) Performance Standard and BS EN 15259:2007 Stacks (East Kilbride, Altrincham, Cirencester and Romford offices) * - The scale r

OCA INSPECCIÓN, CONTROL Y PREVENCIÓN, S.A. (Unipersonal) (OCA GLOBAL)
Pozuelo de Alarcón, ES
Holds: Part 1

EN 16911-1 para la determinación de velocidad y caudal en chimenea. - IT-AT-17 Selección del método de medida de las emisiones a la atmósfera. Límite de cuantificación. - IT-AT-19 Verificación del cumplimiento del valor límite de emisió

NPL Management
Middlesex, GB
Holds: Part 2

EN 16911-2, Environment Agency MID 16911- 2 and other requirements of the Environment Agency (MCERTS) Performance Standard and BS EN 15259:2007 A, C WORKPLACE AND AMBIENT ATMOSPHERIC POLUTANTS, AND OTHER GAS SAMPLES Che

Cura Terrae OH and Emissions Testing
West Yorkshire, GB
Holds: Part 2

EN 16911- (CEMS) - Velocity 2:2013, Environment Agency MID 16911-2 and other requirements of The Environment Agency (MCERTS) Performance Standard and BS EN 15259:2007 Documented in house procedure B TP-04c to

BUREAU VERITAS INSPECCIÓN Y TESTING
Sant Cugat del Vallès, ES
Holds: Part 1 · Part 2

EN 16911 -1 para la determinación de velocidad y caudal en chimenea. - IT-AT-14 Calibración de los sistemas automáticos de medida (SAM, excepto apdos. 8.1.3; 8.1.4; 9.1.3 y 9.1.4.). - IT-AT-16 Entidades encargadas de realizar las tareas

ERGO Umweltinstitut
Dresden, DE
Holds: Part 2

EN 16911-2:2013-06 und DIN EN ISO 16911-2:2013-06 Dresden Volumenstrom DIN EN 16911-2:2013-06 und DIN EN ISO 16911-2:2013-06 Dresden Sauerstoff DIN EN 14789:2017-05 Dresden W

DEKRA INDUSTRIAL, S.A. (Unipersonal)
Bergondo, ES
Holds: Part 1

EN 16911-1 Método interno basado en: UNE 77225 I (**) Método de medición que cumple con los criterios dados en la Norma EN 14793:2017 con respecto al método de referencia UNE-EN 14792 III. Aire ambiente TOMA DE MUESTRAS NORMA/PRO

Olfasense UK
Bristol, GB
Holds: Part 1

EN 16911-1:2013 & EA MID 16911-1 (Method QD019 using differential pressure device pitot tube method) Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1 C Velocity ISO 10780:1994 (QD019) by hot wire

CES Environmental Instruments
Staffordshire, GB
Holds: Part 1 · Part 2

EN 16911-1:2013 & EA MID 16911-1 (W1 4/1 – using differential pressure device (pitot tube) method) (W1 4/56 – using differential pressure device (pitot tube) method) - Gravimat Procedure to meet requirements of PD CEN TR 17078:201

TÜV SÜD Industrie Service
München, DE
Holds: Part 1 · Part 2

EN 16911 -1:2 013 -06; DIN EN 16911 - 2:2013-06 ☒ MUC G, NBG, RGB, STG, MAN, FRE, MGL, HAM Sauerstoff DIN EN 14789:2017 -05 ☒ MUC G, NBG, RGB, STG, MAN, FRE, MGL, HAM Wasserdampf DIN EN 14790:2017 -05 ☒ MUC G, NBG, RGB, STG, MAN,

TÜV SÜD ATISAE, S.A. (Unipersonal)
Tres Cantos, ES
Holds: Part 1 · Part 2

UNE -EN 16911 -1 para la determinación de velocidad y caudal en chimenea. - IT-AT-014 (excepto apartados 8.1.3; 8.1.4; 9.1.3 y 9.1.4). Instrucció Técnia per al calibratge de sistemes automátics de mesura (SAM) - IT-AT-17 Instrucción Téc

GRUPA EKOPROJEKT
Bielsko-Biała, PL
Holds: Part 1

EN 16911-1:2013-07 CEN/TR 17078:2017 Strumień objętości gazu dla ciśnień dynamicznych > 5 Pa Metoda spiętrzenia Prędkość Zakres: (0,4 – 15) m/s Metoda termoanemometryczna PN-Z-04030-7:1994 Pobieranie próbek do oznaczania stężenia

TÜV NORD Umweltschutz GmbH & Co. KG
Hamburg, DE
Holds: Part 1 · Part 2

EN 16911 -1:2013 -06 DIN EN 16911-2:2013-06 H, HB, HAL, BI, E Volumenstrom DIN EN 16911 -1:2013 -06 DIN EN 16911-2:2013-06 H, HB, HAL, BI, E Sauerstoff DIN EN 14789:2017 -05 H, HB, HAL, BI, E Wasserdampf DIN EN 14790:2017

VDZ Service
Düsseldorf, DE
Holds: Part 1

EN 16911 -1:2013 -06 DINEN16911-2:2013-06 DINEN14181:2015-02 VDI 3950 Bl. 1:2018-06 Düsseldorf Volumenstrom DIN EN 16911 -1:2013 -06 DIN EN 16911-2:2013-06 DIN EN 14181:2015-02 VDI 3950 Bl. 1:2018-06 Düsseldorf Sauerstoff

Environmental Compliance
Pontypridd, GB
Holds: Part 1 · Part 2

EN 16911-1:2013 & EA MID 16911-1 (Method ECL/TPD/022A using differential pressure device (pitot tube) method) Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1 A, B Pressure, Temperature and Vel

Hüttentechnische Vereinigung der Deutschen Glasindustrie (HVG)
Offenbach, DE
We don't know yet whether this lab takes outside work.
Holds: Part 1 · Part 2

EN 16911-1:2013-06 DIN EN 16911-2:2013-06 Volumenstrom DIN EN 16911-1:2013-06 DIN EN 16911-2:2013-06 Sauerstoff DIN EN 14789:2017-05 Wasserdampf DIN EN 14790:2017-05 Prüfung der Funktionstüchtigkeit DIN

öko-control GmbH - Ingenieurbüro für Arbeitsplatz- und Umweltanalyse
Schönebeck (Elbe), DE
We don't know yet whether this lab takes outside work.
Holds: Part 1 · Part 2

EN 16911-2: 2013-06 VDI 3950 Bl. 2: 2020-04 Schönebeck Wunstorf Prüfung der Dichtheit DIN EN 14181: 2015-02 VDI 3950, Bl. 1: 2018-06 VDI 3950 Bl. 2: 2020-04 Schönebeck Wunstorf Prüfung der Gerätekennlinie DIN EN 14181: 2015-02

JECMA CONSULTORIA Y MEDIO AMBIENTE
Paterna, ES
We don't know yet whether this lab takes outside work.
Holds: Part 1

EN 16911-1 I II. Aire ambiente TOMA DE MUESTRAS NORMA/PROCEDIMIENTO DE ENSAYO CODIGO Aire ambiente (excluye estaciones de medida fijas y unidades móviles) Muestreo Decreto 151/2006 (BOJA) I PI/03 Método interno basado en UNE-

Infraserv GmbH & Co. Höchst KG Segment Site Services, Abteilungen Gewässerschutz, Immissionsschutz, Umwelt- und Prozessanalytik und Gefahrstoffe/Messstelle
Frankfurt am Main, DE
We don't know yet whether this lab takes outside work.
Holds: Part 1 · Part 2

EN 16911-1:2013-06 DIN EN 16911-2:2013-06 Volumenstrom DIN EN 16911-1:2013-06 DIN EN 16911-2:2013-06 Sauerstoff DIN EN 14789:2017-05 Wasserdampf DIN EN 14790:2017-05 Prüfung der Funktionstüchtigkeit DIN

Mattersteig & Co. Ingenieurgesellschaft für Verfahrenstechnik und Umweltschutz mbH
Markranstädt, DE
We don't know yet whether this lab takes outside work.
Holds: Part 1 · Part 2

EN 16911 -1:2013 -06 M, S

FUNDACIÓN TECNALIA RESEARCH & INNOVATION
Derio, ES
We don't know yet whether this lab takes outside work.
Holds: Part 1

EN 16911-1 I Código Validación Electrónica: f404943560o99AU3yr La acreditación mantiene su vigencia hasta notificación en contra. La presente acreditación está sujeta a modificaciones, suspensiones temporales y retirad

DEKRA Automobil
Stuttgart, DE
We don't know yet whether this lab takes outside work.
Holds: Part 1 · Part 2

EN 16911 -1:2013 -06 DIN EN 16911-2:2013-06 B, BI, HAL, KA, M, S Volumenstrom DIN EN 16911 -1:2013 -06 DIN EN 16911-2:2013-06 B, BI, HAL, KA, M, S Sauerstoff DIN EN 14789:2017 -05 B, BI, HAL, KA, M, S Wa sserdampf DIN EN

Uniper Technologies
Nottingham, GB
We don't know yet whether this lab takes outside work.
Holds: Part 1

EN 16911-1:2013 (Annex C) Tracer Injection and temperature measurement (TOI_006_2) Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objectives 2 and 3 (SOP_008) EA MID EN 16911-2:202

LGA Immissions- und Arbeitsschutz
Nürnberg, DE
We don't know yet whether this lab takes outside work.
Holds: Part 1 · Part 2

EN 16911 -1:2013 -06 DIN EN 16911-2:2013-06 Volumenstrom DIN EN 16911 -1:2013 -06 DIN EN 16911-2:2013-06 Sauerstoff DIN EN 14789:2017 -05 Wasserdampf DIN EN 14790:2 017 -05 Anforderungen AMS Staub

InfraServ GmbH & Co. Gendorf KG Geschäftsbereich Standort- und Umweltservices Abteilung Umweltmessungen
Burgkirchen an der Alz, DE
We don't know yet whether this lab takes outside work.
Holds: Part 1 · Part 2

EN 16911 -1:2013 -06 DIN EN 16911-2:2013-06 Volumenstrom DIN EN 16911 -1:2013 -06 DIN EN 16911-2:2013-06 Sauerstoff DIN EN 14789:2017 -05 Wasserdampf DIN EN 14790:2 017 -05 Prüfung der Funktionstü