Registers refreshed 2026-11-20.See refresh dates

GMW3172 Accredited Testing Labs Worldwide

23 accredited laboratories in 4 countries hold GMW3172 in their accredited scope. We don't know yet whether 11 of them take outside work. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle.

Total labs
23
Countries
4

Available in 4 Countries

United States
13 labs
Germany
3 labs
Canada
2 labs
Honduras
1 lab

Sample labs

Performance Testing Services - PTS
Allendale, MI, US

GMW3172, Aug 2008), Section 9.5.3.2 GMW3172, Section 9.4.3 IEC Standard 6006B-2-14N6, DC-10611 GM9123P (Superseded by GMW3172, Aug 2008), Section 9.1; GM9110P (Superseded by GMW3431, Aug 2007 ) Furniture Testing General Purp

Element Materials Technology Kitchener
Kitchener, CA

GMW3172; HES D6506 [REV.5], Section 5.25 & 5.26; ISO 2808, Sect. 5.2.4; NES M0076 [2023], Sect 24, 25 & 26; RTS.3593, Sect. 6.2; SAE J343, Sect. 4.3; TSL5100G [REV.8], Sect. 4.15; TSM0501G [REV. 16], Sect. 9.13 Abrasion Taber

Bauteilprüfzentrum Scheller
Schweinfurt, DE

GMW3172 2018-04 General Specification for Electrical/Electronic Components – Environmental / Durability GMW14872 March 2013 Cyclic Corrosion Laboratory Test GMW17582 December 2019 PLASTIC COOLANT PLUMBING AND COUPLED JOIN

Element Materials Technology Detroit – Warren 11 Mile
Warren, MI, US

GMW3172 Humidity (5 to 98) % RH MIL-STD-810 Liquid Flow 0.01 cc/min to 35 gpm GM10004C MAST: Multi Axial Simulation Table1 (1 to 50) Hz 6 Degrees of Freedom +/- Three Axis in all Axis Linear Displacement 2.95 (+/-) Angular Displace

TUV SUD America - Auburn Hills
Auburn Hills, MI, US

GMW3172; QE-003; GMW3172; GMW14124; MIL-STD-810, Method 507; IEC 68-2-38 Temperature / Thermal Shock* GMW3172; SAE/USCAR-2; GMW3172; GMW14124; MIL-STD-810, Methods 501, 502, and 503; IEC 60601-1-11 Section 4.2 Environmental;

DEKRA Certification
Plymouth, MI, US

GMW3172; Nissan 98560NDSOO; MIL-STD-810G Methods 501, 502 Humidity1: (10 to 98) % RH GMW3172; Toyota TSF6769G; Nissan 98560NDSOO; MIL-STD-810G Method 507 Thermal Shock1: (-70 to 190) °C GMW3172; Honda S5AA; Toyota TSF6761G; Ni

Auto Technology Company
Strongsville, OH, US

GMW3172 Honda 5100Z-SG0-A000 Honda HES D2003 Honda HES D6001-04A Honda HES D6602 D8N Hyundai MS 600-66 JASO M609 Mazda MCT-1M Mazda MCT-2M Nissan CCT-I - NES

American Testing and Measurement Laboratory (ATM)
San Pedro Sula, Cortes, HN

GMW3172 8.4.3, 9.4.5, 9.4.6 CEPT 0000E412 6.4.5.5, 6.4.5.8, 6.4.8.4 CS.00056 5.3.6, 5, 5.3.7 FCA PF.90051 5.2 FCA PF.90078 5.3.1 FCA PF.90066 5.2 FCA PF.90303 5.1.2, 5.1.3, 7.2.3 TSC1224G TSC1229G FCA PF.90012

Paragon Systems Testing
Concord, CA

GMW3172 Dust; IEC 60529 Degrees of Protection Provided by Enclosures IP5X, IP6X; SAE J575 Lighting Devices and Components – Dust; JIS D 0207 Floating Dust Water/Rain IEC 60068-2-18 Test R and Guidance: Water, IEC 60529 Degrees of

Element Materials Technology Rockford
Rockford, IL, US

GMW3172; IEC 60068-2-14; IPC9592A Salt Fog ASTM B117; RTCA/DO-160 Section 14; MIL-STD-810, Method 509; MIL-STD-202, Method 10 Dripping Rain MIL-STD-810H Method 506.6 Procedure III; RTCA/DO-160 Section 10 On the following prod

PHOENIX TESTLAB
Blomberg, DE

GMW3172 2018 General Specification for Electrical/Electronic Components – Environmental/Durability EMV Great Wall GWT A D05-02:2017- 07 Specification of electromagnetic compatibility for E/E components EMV EMV Grimme Norm 6-

MGA Research Corporation
Troy, MI, US

GMW3172; MIL-STD 810, Method 516.6; GMW14319; MIL-STD-167-1A Dual MAST Exhaust Durability 5’x 7’ Tables 12 Actuator MTS RPC Real-Time Simulation Control Thermal Hot Exhaust Simulation Hot Gas Simulation (0 to 1000) °C D

Kunshan Test Centre
Kunshan, CN
We don't know yet whether this lab takes outside work.

GMW3172; QC/T 627,636; TSF5217G, TSF5217G-1; Z10520, Z10521, Z3024848; Q/LiA9C10008, Q/LiA9C00006, Q/LiA9C31002; Q/JLY J7110195E, Q/JLY J7111507B; Q/JKR J303002 Displacement Measurement (Up to 500) mm CG2501, CG2502;GMW317

MAGNA ENGINEERING CENTER
Grand Rapids, MI, US
We don't know yet whether this lab takes outside work.

GMW3172, PF.90172 Paint/Coatings Measurement1: Adhesion/Scribe GMW14829; ASTM D3359; ISO 2409 Chemical Resistance for Automotive Painted Components (Includes Automotive Fluids, Condiments, Cleaning Agents): Ambient to 80 °C M0133;

Methode Electronics
Apodaca, Nuevo Leon, MX
We don't know yet whether this lab takes outside work.

GMW3172 5-Point Functional/Parametric Check Section 6.1 1-Point Functional/Parametric Check Section 6.2 Jump Start Section 8.2.1 Reverse Polarity Section 8.2.2 Over Voltage Section 8.2.3 State Change Waveform Characterization Section

ELECTRONICA CLARION S.A DE
San Juan del Río, MX
We don't know yet whether this lab takes outside work.

GMW3172, Sections 8.4.2, 9.4.3, 9.4.5, 9.4.6; QQ-B100-00, Sections A4, B3, B6, B14, B16; 3979Z-TG7-L000, Sections 2.11, 2.12, 2.13, 2.14, 2.15, 2.16, 2.17, 2.28, 2.19, 2.20 Thermal Shock (-70 to 190) °C 28401NDS01, Sections CL/01,

North American Lighting Technology Research Center
Farmington Hills, MI, US
We don't know yet whether this lab takes outside work.

GMW3172 sections 8.4.2, 9.4.1, 9.4.3; FMVSS 108 sections 14.6.6; CMVSS 108; J583 5.4; Honda 3310ZT/3350ZT (Internal Heat, Thermal Cycle, High Temperature Exposure, Low Temperature Exposure, High Temperature Operation, Low Temperature

Lear Corporation
Southfield, MI, US
We don't know yet whether this lab takes outside work.

GMW3172, GMW14444; IEC 60068-2-1, 60068-2-2; IEC 60068-2-38, 60068-2-78; PF-12063, PF.90232, PF- A0256; SDS RQT-011000-015910 (ST-0013); ES88005 Thermal Shock Testing Size: (28x24x20)in (-40 to 150) °C IEC 60068-2-14; ISO 16750

GHSP Testing Laboratories
Holland , MI, US
We don't know yet whether this lab takes outside work.

GMW3172; CS.00056 Clause 5.4.6 Acoustics dB vs. Frequency or Time ANSI S1.13; GMW 15607; GMN3965TP; GMW3431 Sound Pressure1 (20 to 145) dB (A) ANSI S1.13; GMW 15607 Operational & Vibrational Noise ANSI S1.13; GMW 15607; PF.90208S Claus

MAGNA INTERNATIONAL - MAGNA ELECTRONICS
Auburn Hills, MI, US
We don't know yet whether this lab takes outside work.

GMW3172; GMW3172 (2023, 2022, 2018), Sections 8.2, all tests & Section 9.2, all tests except 9.2.16 1 When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the version that imme

HELLA GmbH & Co. KGaA
Lippstadt, DE
We don't know yet whether this lab takes outside work.

GMW3172 (2015-06) General Specification for Electrical/Electronic Components - Environmental/Durability Chapter 9.3.1, 9.3.2, 9.3.3, 9.3.4, 9.3.10 only Umwelt GMW3172 (2018-04) General Specification for Electrical/Electronic Componen

Hella Automotive Mexico
San Pedro Tlaquepaque, Jalisco, MX
We don't know yet whether this lab takes outside work.

GMW3172, Sections 8.2.4, 8.2.5, 9.2.2, 9.2.6, 9.2.7, 9.2.9, 9.2.14, 9.2.10, 9.4.3, 9.4.5, 9.4.6; GS 95024-3-1 (2013-07-01), Sections 10.4.3, 16.2; GS 95024-2-1, Section 4.14; ISO 1172; ISO 7637-2; 16750-2; Lamborghini: LAH.8K0.945, S

Aptiv
Warren, OH, US
We don't know yet whether this lab takes outside work.

GMW3172 Mechanical Shock1 Waveform: Half-Sine Maximum g Level: 200 gn SAE/USCAR-2; Q-1000-207; GM 9123P; SAE J2030; TSC-1000G; GMW3191; GMW3172 Thermal Aging1 Thermal Aging1 Temperature Range: (-55 to 300) °C SAE/USCAR-2;