FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates

IEC 60502 Accredited Testing Labs Worldwide

IEC 60502, all parts. Each lab card shows which parts it holds.

12 accredited laboratories in 8 countries hold IEC 60502 in their ISO/IEC 17025 scope. Primary accreditors include Deutsche Akkreditierungsstelle, American Association for Laboratory Accreditation. In the register, IEC 60502 scope entries most often cover Carbon Black Content, Flame Propagation Resistance, Halogenów in Water.

Total labs
12
Countries
8

Available in 8 Countries

Germany
4 labs
United States
2 labs
Italy
1 lab
Netherlands
1 lab
Poland
1 lab
Qatar
1 lab
Sweden
1 lab
United Kingdom
1 lab

Top matrices for IEC 60502

Top analytes for IEC 60502

  • Carbon Black Content (1)
  • Flame Propagation Resistance (1)
  • Halogenów (1)
  • Separation Sheath Material (1)
  • Short-Time (Symmetrical) Withstand Current (1)

Sample labs

Westenergie Netzservice GmbH Eurotest
Dortmund, DE
Holds: Part 1 · Part 2 · Part 4

IEC 60502 -2:20 24 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) − Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV).

VDE Prüf- und Zertifizierungsinstitut
Offenbach am Main, DE
Holds: Part 1 · Part 2

IEC 60502-1:2004/AMD1:2009 Starkstromkabel mit extrudierter Isolierung und deren Garnituren für Nennspannungen von 1 kV (U m = 1,2 kV) bis 30 kV (U m = 36 kV) - Teil 1: Kabel für Nennspannungen von 1 kV (U m = 1,2 kV) und 3 kV (U m = 3

Stowarzyszenie Elektryków Polskich, ul. Świętokrzyska 14, 00-050 Warszawa, Biuro Badawcze ds. Jakości
Warszawa, Biuro Badawcze ds. Jakości, PL
Holds: Part 1 · Part 2

IEC 60502-1:2021-02 p.18.18 IEC 60502-1:2004+A1:2009 p.18.17 IEC 60502-2:2014+AMD1:2024 p.18.2.4 Wydłużenie trwałe izolacji i powłok max. 250 °C PN-EN 60811-507:2012 EN 60811-507:2012 IEC 60811-507:2012 Ubytek masy izolacji i powł

IMQ SpA
Milano, IT
Holds: Part 1 · Part 2

IEC 60502-2:2014, IEC 60502-2:2014/A1:2024 _ Determinazione delle dimensioni esterne/Measurement of overall dimensions, Misura dello spessore della guaina/Measurement of thickness of sheath, Misura dello spessore isolante/Measurement of i

DEKRA Certification
ARNHEM, NL
Holds: Part 1 · Part 2

IEC 60502-1; IEC 60502-2; IEC 60754; IEC 60800; IEC 60840; IEC 62067 DEKRA K 42; DEKRA K 102 DEKRA K 146; DEKRA K 151; DEKRA K 152; DEKRA K 157 DEKRA K 158; DEKRA K160 DEKRA K 161; DEKRA K 162 DEKRA K 163; DEKRA K 164 DEKRA K 165;

Frontier Group International WLL
Doha, QA
Holds: Part 1 · Part 2

(A2LA Cert No. 5108.01) 12/31/2024 Page 5 of 8 Description of Inspection Procedure and/or Specification Further Description of Inspection Activities Product Type Electrical equipment FGI Procedures: L4-TPI-013 L4-TPI-029 L4-

IPH Institut "Prüffeld für elektrische Hochleistungstechnik"
Berlin, DE
Holds: Part 1 · Part 2 · Part 4

IEC 60502-1: 2021-02 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) – Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV).

Hitachi Energy Sweden
Ludvika, SE
Holds: Part 2

IEC 60502-2 Kablar Ja 2 IEC 60507 Isolatorer Ja 2 IEC 60811-401 Kablar Ja 2 IEC 60840 Kablar Ja 2 IEC 60885-3 Kablar Ja 2 IEC 61057 Arbete med spänning Ja 2 IEC 61284 Montagematerial Ja 2 IEC 61869-14 Mättransformatorer Ja 2 IEC 61869-2 Mät

BASEC Group
Milton Keynes, GB
Holds: Part 1 · Part 2

IEC 60502-2:2014, Cl.19.18, 19.22 IEC / BS EN 60811-502 IEC / BS EN 60811-503 BS 6622:2007+C1+C2, Cl. 19.12.2 BS EN 60811-1.3 BS 7835:2007+C1, Cl. 20.18 BS 7870-4.10:2011+A1:2016, Cl. 7.3, 8.1.2, 8.1.6, 8.1.7 BS 7870-4.11:2011+A1:20