ISO 6507-2 Accredited Testing Labs Worldwide
15 accredited laboratories in 4 countries hold ISO 6507-2 in their accredited scope. We don't know yet whether 5 of them take outside work. Primary accreditors include American Association for Laboratory Accreditation, Comité français d'accréditation.
Available in 4 Countries
Sample labs
ISO 6507-2 Verification of forces by an Load cell Stage micrometer Stopwatch US Indirect Verification of Brinell Hardness Testers at Test Conditions 3 – 10/3000 5/750
ISO 6507-2 ASTM E384 ASTM E92 Blocs de référence
ISO 6507-2 Vickers Macrohardness (HV-5000 g, 10 000 g) ASTM E92; EN 1043-1; ISO 6507-1; EN ISO 9015-1 Leeb Hardness ASTM A956 Metallographic Analysis Preparation ASTM E3 Case Depth (Optical and Effective) ATS MAT-P-905; SAE
ISO 6507-2); Force-proving Instrument Stage micrometer Note: this is only a partial direct calibration Indirect Verification of Brinell Hardness Testing Machine3 (250 to 450) HBW (100 to 250) HBW (225 to 450) HBW
ISO 6507-2, ISO 6507-4, ISO 9015-1 WI-B2 ASTM E10, ISO 6506-1, ISO 6506-2, ISO 6506-4, ISO 9015-1 WI-B3 ASTM A370, ASTM E18, ISO 6508-1, ISO 6508-2 VDM 5 Determination of weld defects in fillet welds; Fillet weld fracture test WI
ISO 6507-2 ASTM E384 ASTM E92 Principaux moyens utilisés : Blocs de référence NF EN ISO 6507-3 et ASTM E384 Sur site Machines de dureté VICKERS Dureté Vérification globale de la machine de dureté par méthode directe : comparais
ISO 6507-2 ASTM E384 Principaux moyens utilisés : Blocs de référence Sur site Moutons pendules équipés d’un couteau de rayon de courbure de 2 mm Energie de rupture Vérification globale du mouton-pendule par méthode indirecte NF EN I
ISO 6507-2 Standard Test Methods for Vickers Hardness and Knoop Hardness of Metallic Materials (HV-5000 g, 10 000 g) ASTM E92; EN 1043-1; ISO 6507-1; EN ISO 9015- 1 Case Depth (Optical and Effective) ATS MAT-P-905*; SAE J423; ASM
ISO 6507-2 ISO 6507-2 ASTM E384 ASTM E92 / Sur site Moutons Pendules Flexion par choc Energie de rupture Vérification globale du mouton-pendule par comparaison à des matériaux de référence Charpy V d’énergie de rupture NF EN 100
Parameter/Equipment Range CMC2, 6, 7 (±) Comments Indirect Calibration of Superficial Hardness Testers3 (cont) HR15T: Low Medium High HR30T: Low Medium High 0.23 HR15T(W) 0.29 HR15T(W) 0.13 HR15T(W)
ISO 6507-2, ISO 6507-4, ISO 9015-1, ASTM E92 SOP 11.07 ISO 6506-1, ISO6506-2, ISO 6506-4 8. Determination of the content [%] of elements: Al, Sb, Ar, B, Ca, C, Cr, Co, Cu, Mn, Mo, Ni, Nb, N, P, Si, S, Sn, Ti, V, Zr, Ceq; Optical Emi
ISO 6507-2 ASTM E384 ASTM E92 Principaux moyens : blocs de référence Sur site
ISO 6507-2 ASTM E92/ASTM E384-11e1, ISO 4545-2 Indirect Verification of Brinell Hardness Testers at Test Conditions 3 – 10/3000/15 10/1000 10/500/15 5/750 5/250 2.5/187.5 2.5/62.5 1/30 1/10 1/5
ISO 6507-2 ASTM E92 Principaux moyens utilisés : Etalons de dureté NF EN ISO 6507-3 Etalons de dureté ASTM E92 / ASTM E384 Capteurs de force Micromètres objet Logiciel CVM Mesure Sur site Machines de dureté KNOOP Dureté Vérifica
Parameter/Equipment Range CMC2 (±) Comments Indirect Verification of Vickers Microindentation Hardness Testers (<1 kgf)3 HV (<1 kgf): <240 HV >600 HV 0.82 µm 0.33 µm ASTM E92, ISO 6507-2, ASTM E384 ___