Timet UK
West Midlands, GB
United Kingdom Accreditation Service (UKAS) is the national accreditation body of the United Kingdom. UK laboratories gain accreditation by passing a UKAS assessment of the specific tests and calibrations they offer. This directory lists 1,116 laboratories holding active ISO/IEC 17025 accreditation from UKAS in 13 countries, 1,091 of them in the United Kingdom. Official site: www.ukas.com.
Each type-of-testing page lists the labs of every accreditation body.
West Midlands, GB
Devon, GB
BS 1377-2:2022 Laboratory Particle size distribution - wet sieving BS 1377-2:2022 Laboratory Particle size distribution - dry sieving BS 1377-2:2022 Laboratory Particle density(gas jar) BS 1377-2: 2022 Laboratory
North Lincolnshire, GB
BS EN 14630:2006 Site Resistivity Concrete Society Technical Report No. 60 Documented In-House Method ITP 05 – issue 10 rev 1 Site Rebar continuity Documented In-House Method ITP 08 – issue 10 rev 1 Site Sampli
Somerset, GB
Chelmsford, GB
Surrey, GB
Bury, GB
Derby, GB
BS 8888 Pride Park General dimensional measurements, made using a coordinate measuring machine, with best measurement capability of: Length, Diameter and Position 0 to 1500 x 3200 x 1100 mm – 5.0 + (10 x length in m) µm
Stockport, GB
Tyne & Wear, GB
Buckland Road, Penmill Trading Estate, Yeovil, Somerset , United Kingdom, GB
BS EN ISO 6507-1:2023 Rockwell (HRBW and HRC Scales) BS EN ISO 6508-1:2023
Wales, GB
UN Chapter 6.1 Packagings Boxes: Fibreboard Plastics Wooden Drop tests (preconditioning at -18°C (plastics)) Stack tests (ambient temperature only) Operational Instructions for UN Test Stations issued by VCA Dangerous
Berkshire, GB
Falkirk, GB
Rotherham, GB
Co Durham, GB
Hertfordshire, GB
Hampshire, GB
BS EN IEC 55014-1:2021, Excludes EN 61000-4-20 TEM Cell and EN 61000-4-22 FAR optional testing A, B Information Technology Equipment AC / DC Mains Port BS EN 55025:2017 Excluding clauses 5, 6.6 & 6.7 A, B Electrical Equipment
Glasgow, GB
BS EN 15259:2007 Oxygen* BS EN 14789:2017 (WI/EM/1273 - Validated Zirconium cell analyser) B Sulphur dioxide* PD CEN/TS 17021:2017 (WI/EM/0058 – NDIR analyser) B Total Gaseous Organic* Carbon (TOC / VOC) (0
Warrington, GB
Cambridge, GB
Chorley, GB
HSG 248) – 2021 ASBESTOS IN BULK MATERIALS including materials and products suspected of containing asbestos Identification of: Amosite Chrysotile Crocidolite Fibrous Actinolite Fibrous Anthophyllite Fibrou
Hertfordshire, GB
Oxfordshire, GB
Stone, GB
Stafford, GB
London, GB
Wiltshire, GB
London, GB
BS EN ISO 16649-3: 2015 L, P, Y (Excludes dried foods and brine) 4) FNES131 using MPN TEMPO method P MILK AND DAIRY PRODUCTS Enumeration: *Coliforms, confirmed FNES41 (D4) based on BS EN ISO 4832:2006 L, P, Y
Oxon, GB
Hampshire, GB
EN 13830:2003 Annex V - Testing Laboratory (AVCP) System 3 - including testing away from site (Article 46) Doors, windows, shutters, blinds, gates and related building hardware (1/1): Windows (with or without related hardware)
Nottingham, GB
BS EN ISO 23210:2009 (TOI_001_3) A On-Site Testing Stack Emissions - Continuous Emissions Monitoring Systems (CEMS) (excluding dust monitors and cross duct systems) Functional Testing: Linearity Zero Span Response
Lancaster, GB
Glasgow, GB
Lancashire, GB
Glasgow, GB
Warrington, GB
BS EN ISO 11731:2017 using membrane filter on plate, using GVPC [Matrix A; Procedure 7, Media C] A Surface water Isolation and enumeration and confirmation of Salmonella spp (excluding Salmonella typhi) QI 241/01 membrane filtr
London, GB
West Sussex, GB
Greater Manchester, GB
EN 13162:2012 + A1:2015 EN 13163:2012 + A1:2015 EN 13164:2012 + A1:2015 EN 13165:2012 + A2:2016 EN 13166:2012 + A2:2016 EN 13167:2012 + A1:2015 EN 13168:2012 + A1:2015 EN 13169:2012 + A1:2015 EN 13170:2012 + A1:2015 EN 13171:2012 +
Manchester, GB
Cheshire, GB
CLM 176 (ASI 26): Gamma Spectrometry CLM 213 (ASI 64): ICP-OES Citric acid strength CLM 93: Titrimetry pH CLM 175 Suspended Solids CLM 32: Filtration and gravimetric determination Chemical Oxygen Demand CLM 19
Bedford, GB
BS EN 60068-2-1: 1993(1994) BS EN 60068-2-1: 2007 PRODUCTS STRUCTURES, COMPONENTS Max temp: 110 °C Min temp: -60 °C BS EN 60068-2-2: 1993 BS EN 60068-2-2: 2007 AND FITTINGS Max chamber working area: 11 m x 5 m x 4 m H
Lancashire, GB
BS EN 60068-2-2:2007 (Constant and cyclic) COMPUTERS & PERIPHERALS Max temp: + 120 °C Max chamber size: CONSTRUCTION PLANT 3 m x 4 m x 6 m AND EQUIPMENT LOW TEMPERATURE BS EN 60068-2-1:2007 ELECTRICAL CABLES (Consta
Pembroke, GB
Tyne and Wear, GB
Nuneaton, GB
South Wales, GB
BS EN 13726:2023 Annex B B, N TM-507 Fluid retention capacity BS EN 13726:2023 Annex C B, N TM-507 Absorption under compression BS EN 13726:2023 Annex D TM-508 B, N Fluid Handling Cap
Birmingham, GB
Southampton, GB
Showing labs 1,001–1,050 of 1,116.
Each lab page shows which of its certificates are active.
Search covers every UKAS lab we hold, filtered to this body, and narrows further by country, city or a term from the scope text itself.
Search UKAS accredited labs