Registers refreshed 2026-11-20.See refresh dates
Accredited lab directory

ASTM E23 Accredited Testing Labs in Italy

44 laboratories in Italy are accredited by ACCREDIA to perform ASTM E23 testing. We don't know yet whether 20 of them take outside work. From the accredited scope text: “ASTM E23-25 Pendolo di Charpy Prove di trazione a temperatura ambiente/Tensile testing at room temperature ((2÷250kN)) Prove di trazione a temperatura ambiente/Tensile testing at room temperature ((2÷” “ASTM E23-24 Pendolo di Charpy Prove di trazione a temperatura elevata/Tensile testing at elevated temperature (Da 2 a 200 kN; Da 80 a 900°C) UNI EN ISO 6892-2:2018 Trazione Prove di trazione a tempera” “ASTM E23-24 Pendolo di Charpy Prove di stress rupture/Stress-Rupture Tests (1 kN ÷ 45 kN) Prove di stress rupture/Stress-Rupture Tests (1 kN ÷ 45 kN) ASTM E139-11(2018) ASTM E292-24 _ _ Prove di trazi” “ASTM E23-25 - solo/only Intaglio a "V" Pendolo di Charpy Prove di resilienza/Impact test, Prove di trazione/Tensile testing ( 0-450J ; da T.amb a -80°C; -196°C) ASTM A370-24a - solo/only Intaglio a "V”

Labs
44
Primary AB
ACCREDIA44 labs

Accredited Labs

Pontlab

Pontedera, IT

Scope

ASTM E23-25 - escluso/except par. 9.2.2, 9.2.3 e 9.2.4 Pendolo di Charpy Suscettibilità all'infragilimento da Idrogeno/Susceptibility to embrittlement in hydrogen ASTM G142-98(2022) Test a deformazione lenta (SSRT) in ambiente aggressiv

View lab

Apave Italia CPM Srl - Laboratorio Prove Meccaniche

Bienno, IT

Scope

ASTM E23-18, ASTM E23-23, ASTM E23-23a, ASTM E23-24, ASTM E23-25 ASTM A370-05, ASTM A370-19e1, ASTM A370-20, ASTM A370-21, ASTM A370-22, ASTM A370-23, ASTM A370-24, ASTM A370-24a - solo/only par. da 20 a 29 Prove di trazione a basse tempe

View lab

BYTEST s.r.l.

Volpiano, IT

Scope

ASTM E23-24 Pendolo di Charpy Prove di stress rupture/Stress-Rupture Tests (1 kN ÷ 45 kN) Prove di stress rupture/Stress-Rupture Tests (1 kN ÷ 45 kN) ASTM E139-11(2018) ASTM E292-24 _ _ Prove di trazione a temperatura ambiente/Ten

View lab

IRCM - ISTITUTO RICERCA CONTROLLO MATERIALI

Solbiate Arno, IT

Scope

ASTM E23-25 Pendolo di Charpy ASTM A1058-19 + ASTM E8/E8M-25 Trazione Leghe di nichel con presenza di cromo/Nickel-Rich chromium-bearing alloys, Leghe di Nichel/Nickel alloys Denominazione della prova / Campi di prova Metodo di prova

View lab

Quality Sider Verification

Marcianise, IT

Scope

ASTM E23-25 Pendolo di Charpy ASTM A370-24a EN ISO 6892-1:2019, ISO 6892-1:2019, UNI EN ISO 6892-1:2020 _ Trazione Prove di trazione a temperatura ambiente/Tensile testing at room temperature (1÷200KN) ASTM E8/E8M-24 Trazione Prove

View lab

L.P.M. S.N.C. DI MOLINARI VINCENZO E C.

Gragnano Trebbiense, IT

Scope

ASTM E23-25 Pendolo di Charpy Prove di resilienza/Impact test (0,1 ÷ 600 J -196 ÷ 25 °C) ASTM A370-24a Prove di trazione a temperatura ambiente/Tensile testing at room temperature (3 ÷ 1500 kN) EN ISO 6892-1:2019, ISO 6892-1:2019, UNI

View lab

A.Q.C.

Napoli, IT

Scope

ASTM E23-25 Prove di resilienza/Impact test, Prove di trazione/Tensile testing ASME BPVC II.a SA 370:2025 Prove di stress rupture/Stress-Rupture Tests (0 - 100 kN) Prove di trazione a temperatura elevata/Tensile testing at elevated tem

View lab

GLOBAL TEST

Marcon, IT

Scope

ASTM E23-24 Pendolo di Charpy Prove di trazione a temperatura elevata/Tensile testing at elevated temperature (Da 2 a 200 kN; Da 80 a 900°C) UNI EN ISO 6892-2:2018 Trazione Prove di trazione a temperatura elevata/Tensile testing at ele

View lab

Laboratorio T.O.S.I.

Legnano, IT

Scope

ASTM E23-25 Data: 21/11/2025 pag. 5 di 5 Pendolo di Charpy Prove di trazione a temperatura ambiente/Tensile testing at room temperature (0,2 ÷ 1000 kN ) Prove di trazione a temperatura elevata/Tensile testing at elevated temperatu

View lab

Studio Sperimentale Metalsiderurgico SSM

Bolzaneto, IT

Scope

ASTM E23-25 Pendolo di Charpy Prove di resilienza/Impact test (da 0 J a 450 J / -196°C e da -50°C a +20°C) ASTM A370-24a - solo/only KV2 _ Prove di trazione a temperatura ambiente/Tensile testing at room temperature (3 kN - 600 kN) P

View lab

MEGA-LAB

Albano Sant'Alessandro, IT

Scope

ASTM E23-25 Pendolo di Charpy Prove di trazione a temperatura ambiente/Tensile testing at room temperature ISO 6892-1:2019, UNI EN ISO 6892-1:2020 Prove di trazione a temperatura ambiente/Tensile testing at room temperature ASTM E8/E8M

View lab

LABORATORIO PROVE MATERIALI S. MARCO

Schio, IT

Scope

ASTM E23-25 - escluso/except Par. 9.4 Pendolo di Charpy Pendolo di Charpy Prove di resilienza/Impact test Prove di stress rupture/Stress-Rupture Tests Prove di stress rupture/Stress-Rupture Tests Prove di trazione a temperatura ambien

View lab

IRTEC SRL ISTITUTO RICERCHE TECNOLOGICHE E COLLAUDI

Trezzo sull'Adda, IT

Scope

ASTM E23-25 Pendolo di Charpy Prove di resilienza/Impact test Prove di trazione a temperatura ambiente/Tensile testing at room temperature ASTM A370-24a EN ISO 6892-1:2019, ISO 6892-1:2019, UNI EN ISO 6892-1:2020 _ Trazione Prove di

View lab

C.T.S. Centro Tecnologico Sperimentale

Ceparana di Bolano, IT

Scope

ASTM E23-25 Pendolo di Charpy Prove di trazione a temperatura ambiente/Tensile testing at room temperature (0 - 600 kN) UNI EN ISO 6892-1:2020 - solo/only Met. B Prove di trazione a temperatura ambiente/Tensile testing at room temperatu

View lab

S.M.T. S.r.l.

Pozzo d'Adda, IT

Scope

ASTM E23-18, ASTM E23-25 Pendolo di Charpy Prove di resilienza/Impact test (da 2,5 J a 500 J / da +200°C a -140°C ; -196°C) EN 10045-1:1990 Prove di stress rupture/Stress-Rupture Tests (da 0,3kN a 50kN, fino a +800°C) ASTM E292-24 _

View lab

Parco Scientifico e Tecnologico d'Abruzzo

Chieti, IT

Scope

ASTM E23-25 Pendolo di Charpy Prove di resilienza/Impact test, Prove di trazione/Tensile testing (Resilienza (0,1÷500 J) - Trazione (1-600 KN)) ASTM A370-24, ASTM A370-24a _ Prove di trazione a temperatura ambiente/Tensile testing at

View lab

White Lab s.r.l. - C.T.R.

Limena, IT

Scope

ASTM E23-24 Pendolo di Charpy Pendolo di Charpy Prove di trazione a temperatura ambiente/Tensile testing at room temperature (0,1-1000 KN) Prove di trazione a temperatura ambiente/Tensile testing at room temperature (0,1-1000 KN) UNI E

View lab

AQM SrL

Provaglio D'Iseo, IT

Scope

ASTM E23-25 Pendolo di Charpy ASTM A370-24a - solo/only sez da 20 a 29 _ UNI EN ISO 6892-1:2020 Dinamometria ASTM E8/E8M-25 Trazione ASTM A370-24a - solo/only sez da 7 a 14 UNI EN ISO 7539-2:1997, UNI EN ISO 7539-4:1997 _ _ _ T

View lab

Quality Control Group

Medolago, IT

Scope

ASTM E23-25 Pendolo di Charpy Prove di resilienza/Impact test (0,1÷450 J) Prove di trazione a temperatura ambiente/Tensile testing at room temperature (1÷600000 N) Prove di trazione a temperatura ambiente/Tensile testing at room temper

View lab

I-TT LAB SRL

Sumirago, IT

Scope

ASTM E23-25 Prove di trazione a temperatura ambiente/Tensile testing at room temperature (fino a 600 kN) ISO 6892-1:2019 Prove di trazione a temperatura ambiente/Tensile testing at room temperature (fino a 600 kN) ASTM E8/E8M-25 - esclu

View lab

Laboratorio Prove Bavaro

Caravaggio, IT

Scope

ASTM E23-25 Pendolo di Charpy Prove di resilienza/Impact test (0 ÷ 300 Joule) Prove di trazione a temperatura ambiente/Tensile testing at room temperature (0 ÷ 600 kN) Prove di trazione a temperatura ambiente/Tensile testing at room te

View lab

METAL SERVICES MATERIALS TESTING Srl a socio unico

Ronchi dei Legionari, IT

Scope

ASTM E23-25 Pendolo di Charpy Pendolo di Charpy Prove di trazione a temperatura ambiente/Tensile testing at room temperature (≤ 1200 kN) Prove di trazione a temperatura ambiente/Tensile testing at room temperature (≤ 1200 kN) UNI EN IS

View lab

STUDIO V.M.

Ferrara, IT

Scope

ASTM E23-23a Prove di trazione a temperatura ambiente/Tensile testing at room temperature (fino a 600kN) ASTM E8/E8M-22 Prove di trazione a temperatura ambiente/Tensile testing at room temperature (fino a 600kN) UNI EN ISO 6892-1:2020 -

View lab

SIGMATRE LAB S.R.L.

Garbagnate Monastero, IT

Scope

ASTM E23-18, ASTM E23-23a, ASTM E23-24, ASTM E23-25 ASTM A370-19e1 + ASTM E8/E8M-16a, ASTM A370-20 + ASTM E8/E8M-16ae1, ASTM A370-20 + ASTM E8/E8M-21, ASTM A370-21 + ASTM E8/E8M-21, ASTM A370-21 + ASTM E8/E8M-22, ASTM A370-22 + ASTM E8/E8M

View lab

Pegasus

Favria, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-25 Prove di trazione a temperatura ambiente/Tensile testing at room temperature (0÷150kN) UNI EN ISO 6892-1:2020 - solo/only Annex D Prove di trazione a temperatura ambiente/Tensile testing at room temperature (0÷150kN) ASTM E8

View lab

OFAR

Visano, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-25 Pendolo di Charpy Prove di trazione a temperatura ambiente/Tensile testing at room temperature (FINO A 600KN) ISO 6892-1:2019 Prove di trazione a temperatura ambiente/Tensile testing at room temperature (FINO A 600KN) ASTM

View lab

LAB.MET. srl Laboratorio per i metalli e la metallurgia a socio unico

Maniago, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-25 Pendolo di Charpy Prove di trazione a temperatura ambiente/Tensile testing at room temperature (fino 600 kN) ISO 6892-1:2019, UNI EN ISO 6892-1:2020 Prove di trazione a temperatura ambiente/Tensile testing at room temperatur

View lab

METALCAM

IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-25 - escluso/except §9.4 Pendolo di Charpy ASTM A370-24a - solo/only § 7 - Tension Test; § 20 - Charpy Impact Testing _ Prove di trazione a temperatura ambiente/Tensile testing at room temperature (10 - 200 kN) EN ISO 6892-1:2

View lab

Officine Ambrogio Melesi e C.

Cortenova, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-25 - solo/only Intaglio a "V" Pendolo di Charpy Prove di resilienza/Impact test, Prove di trazione/Tensile testing ( 0-450J ; da T.amb a -80°C; -196°C) ASTM A370-24a - solo/only Intaglio a "V" _ Prove di trazione a temperatura

View lab

Italfond

Bagnolo Mella, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-23, ASTM E23-23a, ASTM E23-24, ASTM E23-25 Pendolo di Charpy Prove di trazione a temperatura ambiente/Tensile testing at room temperature (fino a 250 KN) ASTM E8/E8M-16a, ASTM E8/E8M-16ae1, ASTM E8/E8M-22, ASTM E8/E8M-24, ASTM E

View lab

FMA FELB FORGING GROUP

Arese, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-25 Prove di trazione a temperatura ambiente/Tensile testing at room temperature (6÷300 kN) ASTM E8/E8M-24 Pendolo di Charpy Pendolo di Charpy Trazione Prove di trazione a temperatura ambiente/Tensile testing at room temperatu

View lab

MANGIAROTTI

Monfalcone, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-02a , ASTM E23-25 Pendolo di Charpy Prove di resilienza/Impact test (450 J) Prove di resilienza/Impact test (450 J) ASTM A370-24a EN 10045-1:1990 Prove di trazione a temperatura ambiente/Tensile testing at room temperature

View lab

Foroni

Gorla Minore, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E2375-22 Ultrasuoni _ API Specifica 6A 21st Ed 2018 + Errata 1:2019 + Errata 2:2020 + Errata 3:2020 + Addendum 1:2020 + Addendum 2:2021 + Errata 4:2021 + Addendum 3:2022 + Errata 5:2024 + Errata 6:2024 - solo/only PSL3 and PSL4 Par.

View lab

CMF S.P.A. - Laboratorio Prove

Cormons, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-25 Pendolo di Charpy Prove di trazione a temperatura ambiente/Tensile testing at room temperature ((2÷250kN)) Prove di trazione a temperatura ambiente/Tensile testing at room temperature ((2÷250kN)) UNI EN ISO 6892-1:2020 Traz

View lab

Dipartimento 'Laboratorio Forgerossi Research'

Cogollo del Cengio, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-25 Pendolo di Charpy Prove di trazione a temperatura ambiente/Tensile testing at room temperature (5 ÷ 250kN) Prove di trazione a temperatura ambiente/Tensile testing at room temperature (5 ÷ 250kN) UNI EN ISO 6892-1:2020 Traz

View lab

Laboratori della Cogne Acciai Speciali

Aosta, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-25 Pendolo di Charpy Prove di trazione a temperatura ambiente/Tensile testing at room temperature ISO 6892-1:2019 Prove di trazione a temperatura ambiente/Tensile testing at room temperature ASTM E8/E8M-24 Trazione Trazione

View lab

GALPERTI

Cortenova, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-25 Pendolo di Charpy Prove di resilienza/Impact test, Prove di trazione/Tensile testing ASTM A370-24a - solo/only trazione par.7 e resilienza par.20 _ Prove di trazione a temperatura ambiente/Tensile testing at room temperatur

View lab

INSPECTA

Ravenna, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-23a, ASTM E23-24 Pendolo di Charpy Prove di resilienza/Impact test (0 - 450 J; +20°C a -80°C; - 196°C) ASTM A370-24, ASTM A370-24a _ Prove di trazione a temperatura ambiente/Tensile testing at room temperature (0 - 600 kN

View lab

Ire-Omba

Bergamo, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-25 Prove di trazione a temperatura ambiente/Tensile testing at room temperature (fino a 250 kN) ISO 6892-1:2019 Prove di trazione a temperatura ambiente/Tensile testing at room temperature (fino a 250 kN) ASTM A370-24a + ASTM E

View lab

OMS Saleri

Odolo, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-24 Pendolo di Charpy Prove di resilienza/Impact test (0÷500 J) Prove di trazione a temperatura ambiente/Tensile testing at room temperature (4÷600 KN) Prove di trazione a temperatura ambiente/Tensile testing at room temperatur

View lab

FOMAS S.p.A.

Osnago, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-02a, ASTM E23-12c, ASTM E23-16b, ASTM E23-18, ASTM E23-23, ASTM E23-23a, ASTM E23-24, ASTM E23-25 EN 10045-1:1990, UNI EN 10045-1:1992 EN ISO 6892-1:2009, EN ISO 6892-1:2016, EN ISO 6892-1:2019, ISO 6892-1:2009, ISO 6892-1:2016,

View lab

RIVIT S.p.A SOCIETA' BENEFIT Socio Unico

Caltrano, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-25 Pendolo di Charpy Pendolo di Charpy Prove di resilienza/Impact test (5 - 450J) Prove di trazione a temperatura ambiente/Tensile testing at room temperature (6 - 600 kN) Prove di trazione a temperatura ambiente/Tensile test

View lab

Società Valvosider

Borgosesia, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-25 - escluso/except Section 9.4 Pendolo di Charpy Pendolo di Charpy Prove di trazione a temperatura ambiente/Tensile testing at room temperature ASTM A370-24a + ASTM E8/E8M-25 Trazione Prove di trazione a temperatura ambiente/

View lab

Lucchini RS S.p.A. - Laboratori metallurgici

Lovere, IT

We don't know yet whether this lab takes outside work.
Scope

ASTM E23-25 Pendolo di Charpy EN 10045-1:1990, UNI EN 10045-1:1992 _ UNI EN ISO 6892-1:2020 Trazione Prove di trazione a temperatura ambiente/Tensile testing at room temperature (0÷2500 KN) ASTM E8/E8M-25 Prove di trazione a tempera

View lab

About ISO/IEC 17025 in Italy

Italian Accreditation Body (ACCREDIA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in Italy.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.