MAC Calibrations
, United States, United States
Visit website- Accredited standards
- 2
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 2 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM E1417
ASTM E1444
ASTM E1444; ASTM E1417; ISO/IEC 17025-2017; ANSI/NCSL Z540.1-1994
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active1795.01
The scope document we hold says it is valid until 2027-11-30.
Accredited scope, certificate 1795.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM E1444; ASTM E1417; ISO/IEC 17025-2017; ANSI/NCSL Z540.1-1994 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1795.01) 10/01/2025 Page 2 of 5
Parameter/Equipment
Range CMC2, 4 (±) Comments
DC Voltage – Measure
Up to 100 mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
0.021 mV
0.12 mV
0.0011 V
0.013 V
0.14 V
Digital multimeter
DC Current3 – Measure
Up to 19 990 A
2.5 % of rdg or 12 amps,
whichever is greater
Shunt meter
AC Current3 – Measure
Up to 19 990 A
2.5 % of rdg or 12 amps,
whichever is greater
Shunt meter
HW Current3 – Measure
Up to 19 990 A
2.5 % of rdg or 12 amps,
whichever is greater
Shunt meter
Parameter/Range
Frequency CMC2, 4 (±) Comments
AC Voltage – Measure
Up to 100 mVAC
(0.100 to 1) VAC
(1 to 10) VAC
(10 to 100) VAC
(100 to 750) VAC
10 Hz to 20 kHz
10 Hz to 20 kHz
10 Hz to 20 kHz
10 Hz to 20 kHz
10 Hz to 20 kHz
0.25 mV
2.2 mV
0.022 V
0.22 V
1.7 V
Digital multimeter
II. Magnetic Quantities
Parameter/Equipment
Range CMC2, 7 (±) Comments
DC Gauss3 – Measure
Up to 200 G
Up to 20 G
2.5 % of rdg
5.5 % of rdg or 0.69 G,
whichever is greater
Hall effect meter
Magnetometer
DC Gauss3 – Measuring
Equipment
Up to 75 G
4.4 % rdg or 0.44 G,
whichever is greater
Standard gauss
fixtures | to 19990 A |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1795.01) 10/01/2025 Page 3 of 5
III. Mechanical
Parameter/Equipment
Range CMC2, 7 (±) Comments
Pressure3 – Measure
Up to 300 psig
0.24 % of rdg or 0.23
psig, whichever is
greater
Digital pressure gage
Pressure3 – Measure
Up to 200 psig
1.6 psig
Pressure gage
AC/DC Hand Yoke3
(10 to 40) lb
+2 % of rdg, -0 % of
rdg
Standard weights
Quick Break Tester3
Go/ No Go
N/A
Standard quick break
tester
IV. Optical Quantities
Parameter/Equipment
Range CMC2, 7 (±) Comments
Irradiance3 – Measure
Ultraviolet Light
(320 to 380) nm
Up to 10 000 µW/cm
2
5 % of rdg
Radiometer
Illuminance3 – Measure
Visible Light,
(380 to 760) nm
Up to 3000 Fc,
Up to 32 300 lux
5 % of rdg
Radiometer
Luminance3 – Measure
Visible Light,
(380 to 760) nm
Up to 200 000 Fl
5 % of rdg
Radiometer | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1795.01) 10/01/2025 Page 4 of 5
V. Thermodynamics
Parameter/Equipment
Range CMC2, 7 (±) Comments
Temperature3 – Measure
(-80 to 300) °C
(-112 to 572) °F
(10 to 257) °F
(-11 to 121) °C
0.15 °C
0.25 °F
0.8 °F
0.4 °C
Digital thermometer
VI. Time & Frequency
Parameter/Equipment
Range CMC2, 7 (±) Comments
Time3 – Measure &
Measure Equipment
(0.100 to 20.000) s
Up to 60 min
(1 to 24) hrs
0.01 s
0.39 s
1.3 s
Shunt meter,
Shot duration timer
Stopwatch
Time – Measuring
Equipment
Up to 20.000 s
0.0033 s
Function generator
_______________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. C MCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC. | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1795.01) 10/01/2025 Page 5 of 5
4 The measurands stated are measured with the HP 34401A. This capability is suitable for the calibration of
the devices intended to generate the measurand in the ranges indicated. CMC’s are expressed as either a
specific value that covers the full range or as a combination of the fraction of the reading/output plus a
range specification.
5 In the statement of CMC, Fc represents “Foot Candle”. L ux represents the standard unit of measuring
how much light is available. Fl represents “Foot Lambert”.
6 This scope meets A2LA’s P112 Flexible scope policy.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
8 Please note that the identities of the location for which this CUSTOMER is accredited has been redacted
and is not publicly available. Consideration of such disclosure to any party may be made upon written
request to A2LA with evidence of a demonstrable need to know and only upon approval by the
CUSTOMER itself. | ||
| 6 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in United States
- Aalberts IPSAPageland, SCA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AALFA - KAL Metrology Laboratory, division of AALBORG Instruments & ControlsOrangeburg, NYA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ACR Technical ServicesNewport News, VAA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AH Electronic Test Equipment Repair CenterIslip, NYA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Aldinger Company DBA Quality Control ServicesMilwaukie, ORA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.