MAC Calibrations

, United States, United States

Visit website
A2LA 1795.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
2
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 2 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM E1417
ASTM E1444

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

1795.01

The scope document we hold says it is valid until 2027-11-30.

View scope

Accredited scope, certificate 1795.01

LineMethodMatrixRange
1ASTM E1444; ASTM E1417; ISO/IEC 17025-2017; ANSI/NCSL Z540.1-1994-See scope document
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1795.01) 10/01/2025 Page 2 of 5 Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage – Measure Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V 0.021 mV 0.12 mV 0.0011 V 0.013 V 0.14 V Digital multimeter DC Current3 – Measure Up to 19 990 A 2.5 % of rdg or 12 amps, whichever is greater Shunt meter AC Current3 – Measure Up to 19 990 A 2.5 % of rdg or 12 amps, whichever is greater Shunt meter HW Current3 – Measure Up to 19 990 A 2.5 % of rdg or 12 amps, whichever is greater Shunt meter Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure Up to 100 mVAC (0.100 to 1) VAC (1 to 10) VAC (10 to 100) VAC (100 to 750) VAC 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 0.25 mV 2.2 mV 0.022 V 0.22 V 1.7 V Digital multimeter II. Magnetic Quantities Parameter/Equipment Range CMC2, 7 (±) Comments DC Gauss3 – Measure Up to 200 G Up to 20 G 2.5 % of rdg 5.5 % of rdg or 0.69 G, whichever is greater Hall effect meter Magnetometer DC Gauss3 – Measuring Equipment Up to 75 G 4.4 % rdg or 0.44 G, whichever is greater Standard gauss fixtures
to 19990 A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1795.01) 10/01/2025 Page 3 of 5 III. Mechanical Parameter/Equipment Range CMC2, 7 (±) Comments Pressure3 – Measure Up to 300 psig 0.24 % of rdg or 0.23 psig, whichever is greater Digital pressure gage Pressure3 – Measure Up to 200 psig 1.6 psig Pressure gage AC/DC Hand Yoke3 (10 to 40) lb +2 % of rdg, -0 % of rdg Standard weights Quick Break Tester3 Go/ No Go N/A Standard quick break tester IV. Optical Quantities Parameter/Equipment Range CMC2, 7 (±) Comments Irradiance3 – Measure Ultraviolet Light (320 to 380) nm Up to 10 000 µW/cm 2 5 % of rdg Radiometer Illuminance3 – Measure Visible Light, (380 to 760) nm Up to 3000 Fc, Up to 32 300 lux 5 % of rdg Radiometer Luminance3 – Measure Visible Light, (380 to 760) nm Up to 200 000 Fl 5 % of rdg Radiometer
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1795.01) 10/01/2025 Page 4 of 5 V. Thermodynamics Parameter/Equipment Range CMC2, 7 (±) Comments Temperature3 – Measure (-80 to 300) °C (-112 to 572) °F (10 to 257) °F (-11 to 121) °C 0.15 °C 0.25 °F 0.8 °F 0.4 °C Digital thermometer VI. Time & Frequency Parameter/Equipment Range CMC2, 7 (±) Comments Time3 – Measure & Measure Equipment (0.100 to 20.000) s Up to 60 min (1 to 24) hrs 0.01 s 0.39 s 1.3 s Shunt meter, Shot duration timer Stopwatch Time – Measuring Equipment Up to 20.000 s 0.0033 s Function generator _______________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. C MCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1795.01) 10/01/2025 Page 5 of 5 4 The measurands stated are measured with the HP 34401A. This capability is suitable for the calibration of the devices intended to generate the measurand in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a combination of the fraction of the reading/output plus a range specification. 5 In the statement of CMC, Fc represents “Foot Candle”. L ux represents the standard unit of measuring how much light is available. Fl represents “Foot Lambert”. 6 This scope meets A2LA’s P112 Flexible scope policy. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 8 Please note that the identities of the location for which this CUSTOMER is accredited has been redacted and is not publicly available. Consideration of such disclosure to any party may be made upon written request to A2LA with evidence of a demonstrable need to know and only upon approval by the CUSTOMER itself.
6ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.