Ponce, United States

Visit website
A2LA 3283.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
13
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 13 scope lines.

A2LA certificate 3283.01 · 13 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994pH; Conductivity-
2-Plain Plugs & Pin Gages; External Diameter; Plain Ring Gages; Internal Diameter; Length Standards; Spheres; External Diameter; Gage Blocks; AC Voltage; AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 2 of 12 Parameter/Equipment Range CMC2 (±) Comments Caliper Up to 3 in Up to 6 in 370 µin 1200 µin P & W Labmaster ™ , caliper master Plain Plugs & Pin Gages – External Diameter Up to 1 in 7.2 µin P & W Labmaster™ , gage blocks Plain Ring Gages – Internal Diameter Up to 5 in 11 µin P & W Labmaster ™ , gage blocks Length Standards Up to 12 in 24 µin P & W Labmaster ™ , gage blocks Spheres – External Diameter Up to 1 in 7 µin P & W Labmaster ™ , gage blocks Gage Blocks Up to 12 in 24 µin Mechanical comparison using P & W Labmaster ™ & gage blocks III. Electrical DC/Low Frequency Parameter/Range Frequency CMC 2, 7 (±) Comments AC Voltage – Generate (1 to 2.99) V (3 to 32.99) V (33 to 329.99) V (300 to 1000) V (45 to 1000) Hz 5.7 mV 23 mV 200 mV 600 mV Fluke series 5500A calibrator AC Voltage – Measure (1 to 2.99) V (3 to 19.99) V (20 to 99) V (40 to 1000) Hz 1.6 mV 11 mV 52 mV HP 3458A
See scope document
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 3 of 12 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage – Measure (cont) (100 to 299) V (300 to 499) V (500 to 700) V (40 to 1000) Hz 160 mV 260 mV 320 mV HP 3458A AC Current – Measure (0.100 to 1.99) mA (2 to 19.9) mA (20 to 499) mA (500 to 999) mA (100 to 1999) mA (2000 to 3000) mA (3 to 5000) Hz 3.0 µA 29 µA 0.7 mA 1.5 mA 3 mA 3.8 mA Agilent 34410A AC Current – Generate (1 to 1.99) A (2 to 4.99) A (5 to 7.99) A (8 to 11) A (45 to 1000) Hz 1.9 mA 4.9 mA 6.1 mA 10 mA Fluke series 5500A calibrators Parameter/Equipment Range CMC2, 7 (±) Comments DC Voltage – Generate (1 to 2.99) V (3 to 32.99) V (33 to 329.99) V (300 to 1000) V 0.2 mV 1.9 mV 19 mV 57 mV Fluke series 5500A calibrators DC Voltage – Measure (1 to 2.99) V (3 to 19.99) V (20 to 99) V (100 to 299) V (300 to 499) V (500 to 699) V (700 to 1000) V 0.043 mV 0.29 mV 1.4 mV 4.2 mV 7.2 mV 10 mV 12 mV HP 3458A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 4 of 12 Parameter/Equipment Range CMC2, 7 (±) Comments DC Current – Generate (1 to 1.99) A (2 to 4.99) A (5 to 7.99) A (8 to 11) A 0.63 mA 1.8 mA 3.0 mA 4.2 mA Fluke series 5500A calibrators DC Current – Measure (0.100 to 1.99) mA (2 to 19.9) mA (20 to 499) mA (500 to 999) mA (1000 to 1999) mA (2000 to 3000) mA 2.0 µA 21 µA 0.5 mA 1.0 mA 2.0 mA 3.1 mA Agilent 34410A Resistance – Generate (1 to 1.99) Ω (2 to 19.99) Ω (20 to 199.9) Ω 200 Ω to 1.99 kΩ (2 to 19.9) kΩ (20 to 199) kΩ 200 kΩ to 1.99 MΩ (2 to 19.9) MΩ (20 to 199) MΩ (200 to 330) MΩ 0.01 Ω 0.13 Ω 1.3 Ω 0.01 kΩ 0.12 kΩ 1.3 kΩ 13 kΩ 130 kΩ 1300 kΩ 2100 kΩ Fluke series 5500A calibrators Resistance – Measure (1 to 1.99) Ω (2 to 19.99) Ω (20 to 199.9) Ω 200 Ω to 1.99 kΩ (2 to 19.9) kΩ (20 to 199) kΩ 200 kΩ to 1.99 MΩ (2 to 19.9) MΩ (20 to 199) MΩ (200 to 330) MΩ 0.0018 Ω 0.018 Ω 0.18 Ω 1.8 Ω 18 Ω 180 Ω 1.8 kΩ 18 kΩ 180 kΩ 270 kΩ HP 3458A Electrical Simulation of Thermocouples – Temperature Indicators Type J (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C 0.29 °C 0.24 °C 0.22 °C Fluke series 5500A calibrators
5-thermocouples; RTDs
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 5 of 12 Parameter/Equipment Range CMC2, 7 (±) Comments Electrical Simulation of Thermocouples – Temperature Indicators (cont) Type J Type K Type R Type T (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -30) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.10 °C 0.27 °C 0.35 °C 0.29 °C 0.26 °C 0.28 °C 0.47 °C 0.70 °C 0.44 °C 0.44 °C 0.50 °C 0.66 °C 0.32 °C 0.16 °C 0.17 °C Fluke series 5500A calibrators Temperature Indicators – RTDs Simulation Pt 385 (100 Ω) Pt 3916 (100 Ω) Pt 3926 (100 Ω) (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to -190) °C (-190 to -80) °C (-80 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C 0.06 °C 0.08 °C 0.07 °C 0.13 °C 0.16 °C 0.23 °C 0.28 °C 0.29 °C 0.21 °C 0.16 °C 0.25 °C 0.28 °C 0.06 °C 0.07 °C 0.09 °C 0.11 °C 0.12 °C 0.14 °C Fluke series 5500A calibrators
See scope document
6-nitrogen; air
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 6 of 12 Parameter/Equipment Range CMC2, 7 (±) Comments Temperature Indicators – RTDs Simulation (cont) PtNi 385 (120 Ω) (-80 to 0) °C (0 to 100) °C (100 to 260) °C 0.09 °C 0.09 °C 0.16 °C Fluke series 5500A calibrators Capacitance – Generate (0.33 to 0.4999) nF (0.5 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.999) nF (11 to 32.999) nF (33 to 109.99) nF (110 to 329.99) nF (0.33 to 1.0999) µF (1.1 to 3.2999) µF (3.3 to 10.999) µF (11 to 32.999) µF (33 to 109.99) µF (110 to 329.99) µF (330 to 1100) µF 0.013 nF 0.017 nF 0.030 nF 0.075 nF 0.20 nF 0.65 nF 1.9 nF 0.02 µF 0.03 µF 0.75 µF 0.20 µF 0.65 µF 1.9 µF 6.4 µF Fluke series 5500A calibrators IV. Fluid Quantities Parameter/Equipment Range CMC 2 (±) Comments Fluid Flow – Flowmeters Volume Gas Flow Rate: (Reference Fluid Conditions of 70 °F & 14.696 psia) 0.5 cm 3/min 5 cm3/min 10 cm3/min (50 to 99) cm3/min (100 to 149) cm3/min (150 to 199) cm3/min (200 to 249) cm3/min (250 to 299) cm3/min (300 to 349) cm3/min (350 to 399) cm3/min (400 to 449) cm3/min (450 to 500) cm3/min (20 to 200) ft3/h (0 to 10) ft3/min 0.01 cm3/min 0.04 cm3/min 0.13 cm3/min 1.8 cm3/min 2.2 cm3/min 2.3 cm3/min 2.5 cm3/min 2.8 cm3/min 3 cm3/min 3.2 cm3/min 3.5 cm3/min 3.8 cm3/min 6.3 ft3/h 0.12 ft3/min Alicat volume flow meter Medium: nitrogen, air.
See scope document
7ASME B107.14-2004-See scope document
8ASTM-See scope document
9--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 9 of 12 Parameter/Equipment Range CMC2, 4 (±) Comments Vacuum Manometer, Vacuum Gauges (10 to 20) Torr (20.1 to 50) Torr (50.1 to 80) Torr (80.1 to 100) Torr 0.015 Torr 0.08 Torr 0.12 Torr 0.15 Torr MKS absolute pressure transducers Volume – Pipettes (10 to 50) µL (100 to 1000) µL 0.8 µL + 0.42 % 0.82 µL + 0.42 % Analytical balance VI. Thermodynamics Parameter/Equipment Range CMC 2, 5 (±) Comments Relative Humidity – Measuring Equipment (10 to 55) % RH (55.1 to 95) % RH 0.48 % RH + 0.0058 % RH / % RH 0.13 % RH + 0.012 % RH / % RH High precision humidity calibrator Temperature3 – Measuring Equipment (Digital & Analog Thermometer & Temperature Probe) (-196 to 398) °C (-100 °C to 398) °C 0.05 °C 0.05 °C RTD Temperature probe & readout display Dry block Fluke 9173,9170 & IsoTech 525 ISIS Temperature 3 – Temperature Sources (Dry Blocks, Liquid Baths, Calibrators) (-196 to 400) °C 0.05 °C RTD temperature probe & readout display
-196 to 400 °C
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 10 of 12 Parameter/Equipment Range CMC2 (±) Comments Temperature – Infrared Thermometers 20 °C 0 °C 100 °C 300 °C 500 °C 760 °C 982 °C 1.3 °C 1.5 °C 1.6 °C 2.5 °C 4.3 °C 6.5 °C 8.7 °C Fluke 9133, Fluke 9132 calibrators (emissivity = 0.95) Omega black body Mod: BB-4A (emissivity = 0.99) IR Black Bodies3 (-30 to -1) °C (0 to 150) °C (250 to 982) °C 1.1 °C 1.2 °C 1.7 °C Fluke 566HVA- 566 IR thermometer (emissivity = 0.95) Fluke 5500A series with type K T/C VII. Time & Frequency Parameter/Equipment Range CMC2, 5 (±) Comments Stopwatch Up to 24 h 0.06 s /24 h Timometer Frequency – Measuring Equipment 0.1 Hz 10 Hz 100 Hz 500 Hz 1 kHz 10 k Hz 100 kHz 500 kHz 1 MHz 5 MHz 10 MHz 0.058 mHz 1.0 mHz 9.9 mHz 50 mHz 0.15 Hz 1.0 Hz 10 Hz 15 Hz 22 Hz 74 Hz 0.14 kHz Fluke series 5500A calibrator HP 8165A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 11 of 12 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Frequency – Measuring Equipment (cont) 100 MHz 500 MHz 1000 MHz 1500 MHz 2000 MHz 2500 MHz 3000 MHz 1.3 kHz 6.4 kHz 13 kHz 19 kHz 25 kHz 32 kHz 38 kHz Rohde & Schwarz signal generator Frequency – Measure 0.1 Hz 10 Hz 100 Hz 500 Hz 1 kHz 10 k Hz 100 kHz 500 kHz 1 MHz 5 MHz 10 MHz 100 MHz 3000 MHz 0.000 81 mHz 0.081 mHz 0.81 mHz 0.0043 Hz 0.0061 Hz 0.061 Hz 0.61 Hz 4.3 Hz 0.0061 kHz 0.04 kHz 0.06 kHz 0.61 kHz 18 kHz Agilent frequency counter RPM3 – Contact & Non- Contact Measuring Equipment Measure (599 to 120 000) RPM Photo (10 to 12 000) RPM Contact (10 to 599) RPM (600 to 100 000) RPM 0.17 RPM + 0.0059 % 0.15 RPM + 0.0082 % 1.3 RPM 0.82 RPM + 0.0070 % TIS-RPM calibrator Tachometer ____________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 12 of 12 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, the value is defined as the percentage of reading. 5 The type of instrument or material being calibrate d is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7 The stated measured values are determined usin g the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification
13ISO/IEC 17025:2017; ANSI/NCSLI Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.