W.C. Caribbean Instrument
Ponce, United States
Visit website- Scope lines
- 13
- A2LA certificate
- 1
- Sites in our directory
- 3
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 13 scope lines.
A2LA certificate 3283.01 · 13 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | pH; Conductivity | - |
| 2 | - | Plain Plugs & Pin Gages; External Diameter; Plain Ring Gages; Internal Diameter; Length Standards; Spheres; External Diameter; Gage Blocks; AC Voltage; AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 2 of 12
Parameter/Equipment
Range
CMC2 (±)
Comments
Caliper
Up to 3 in
Up to 6 in
370 µin
1200 µin
P & W Labmaster
™ ,
caliper master
Plain Plugs & Pin Gages –
External Diameter
Up to 1 in
7.2 µin
P & W Labmaster™ ,
gage blocks
Plain Ring Gages –
Internal Diameter
Up to 5 in
11 µin
P & W Labmaster
™ ,
gage blocks
Length Standards
Up to 12 in
24 µin
P & W Labmaster
™ ,
gage blocks
Spheres – External
Diameter
Up to 1 in
7 µin
P & W Labmaster
™ ,
gage blocks
Gage Blocks
Up to 12 in
24 µin
Mechanical
comparison using
P & W Labmaster
™ &
gage blocks
III. Electrical DC/Low Frequency
Parameter/Range
Frequency
CMC
2, 7 (±)
Comments
AC Voltage – Generate
(1 to 2.99) V
(3 to 32.99) V
(33 to 329.99) V
(300 to 1000) V
(45 to 1000) Hz
5.7 mV
23 mV
200 mV
600 mV
Fluke series 5500A
calibrator
AC Voltage – Measure
(1 to 2.99) V
(3 to 19.99) V
(20 to 99) V
(40 to 1000) Hz
1.6 mV
11 mV
52 mV
HP 3458A | See scope document |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 3 of 12
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage – Measure
(cont)
(100 to 299) V
(300 to 499) V
(500 to 700) V
(40 to 1000) Hz
160 mV
260 mV
320 mV
HP 3458A
AC Current – Measure
(0.100 to 1.99) mA
(2 to 19.9) mA
(20 to 499) mA
(500 to 999) mA
(100 to 1999) mA
(2000 to 3000) mA
(3 to 5000) Hz
3.0 µA
29 µA
0.7 mA
1.5 mA
3 mA
3.8 mA
Agilent 34410A
AC Current – Generate
(1 to 1.99) A
(2 to 4.99) A
(5 to 7.99) A
(8 to 11) A
(45 to 1000) Hz
1.9 mA
4.9 mA
6.1 mA
10 mA
Fluke series 5500A
calibrators
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
DC Voltage – Generate
(1 to 2.99) V
(3 to 32.99) V
(33 to 329.99) V
(300 to 1000) V
0.2 mV
1.9 mV
19 mV
57 mV
Fluke series 5500A
calibrators
DC Voltage – Measure
(1 to 2.99) V
(3 to 19.99) V
(20 to 99) V
(100 to 299) V
(300 to 499) V
(500 to 699) V
(700 to 1000) V
0.043 mV
0.29 mV
1.4 mV
4.2 mV
7.2 mV
10 mV
12 mV
HP 3458A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 4 of 12
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
DC Current – Generate
(1 to 1.99) A
(2 to 4.99) A
(5 to 7.99) A
(8 to 11) A
0.63 mA
1.8 mA
3.0 mA
4.2 mA
Fluke series 5500A
calibrators
DC Current – Measure
(0.100 to 1.99) mA
(2 to 19.9) mA
(20 to 499) mA
(500 to 999) mA
(1000 to 1999) mA
(2000 to 3000) mA
2.0 µA
21 µA
0.5 mA
1.0 mA
2.0 mA
3.1 mA
Agilent 34410A
Resistance – Generate
(1 to 1.99) Ω
(2 to 19.99) Ω
(20 to 199.9) Ω
200 Ω to 1.99 kΩ
(2 to 19.9) kΩ
(20 to 199) kΩ
200 kΩ to 1.99 MΩ
(2 to 19.9) MΩ
(20 to 199) MΩ
(200 to 330) MΩ
0.01 Ω
0.13 Ω
1.3 Ω
0.01 kΩ
0.12 kΩ
1.3 kΩ
13 kΩ
130 kΩ
1300 kΩ
2100 kΩ
Fluke series 5500A
calibrators
Resistance – Measure
(1 to 1.99) Ω
(2 to 19.99) Ω
(20 to 199.9) Ω
200 Ω to 1.99 kΩ
(2 to 19.9) kΩ
(20 to 199) kΩ
200 kΩ to 1.99 MΩ
(2 to 19.9) MΩ
(20 to 199) MΩ
(200 to 330) MΩ
0.0018 Ω
0.018 Ω
0.18 Ω
1.8 Ω
18 Ω
180 Ω
1.8 kΩ
18 kΩ
180 kΩ
270 kΩ
HP 3458A
Electrical Simulation of
Thermocouples –
Temperature Indicators
Type J
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
0.29 °C
0.24 °C
0.22 °C
Fluke series 5500A
calibrators | ||
| 5 | - | thermocouples; RTDsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 5 of 12
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Electrical Simulation of
Thermocouples –
Temperature Indicators
(cont)
Type J
Type K
Type R
Type T
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -30) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.10 °C
0.27 °C
0.35 °C
0.29 °C
0.26 °C
0.28 °C
0.47 °C
0.70 °C
0.44 °C
0.44 °C
0.50 °C
0.66 °C
0.32 °C
0.16 °C
0.17 °C
Fluke series 5500A
calibrators
Temperature Indicators –
RTDs Simulation
Pt 385 (100 Ω)
Pt 3916 (100 Ω)
Pt 3926 (100 Ω)
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
0.06 °C
0.08 °C
0.07 °C
0.13 °C
0.16 °C
0.23 °C
0.28 °C
0.29 °C
0.21 °C
0.16 °C
0.25 °C
0.28 °C
0.06 °C
0.07 °C
0.09 °C
0.11 °C
0.12 °C
0.14 °C
Fluke series 5500A
calibrators | See scope document |
| 6 | - | nitrogen; airShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 6 of 12
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Temperature Indicators –
RTDs Simulation (cont)
PtNi 385 (120 Ω)
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
0.09 °C
0.09 °C
0.16 °C
Fluke series 5500A
calibrators
Capacitance – Generate
(0.33 to 0.4999) nF
(0.5 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.999) nF
(11 to 32.999) nF
(33 to 109.99) nF
(110 to 329.99) nF
(0.33 to 1.0999) µF
(1.1 to 3.2999) µF
(3.3 to 10.999) µF
(11 to 32.999) µF
(33 to 109.99) µF
(110 to 329.99) µF
(330 to 1100) µF
0.013 nF
0.017 nF
0.030 nF
0.075 nF
0.20 nF
0.65 nF
1.9 nF
0.02 µF
0.03 µF
0.75 µF
0.20 µF
0.65 µF
1.9 µF
6.4 µF
Fluke series 5500A
calibrators
IV. Fluid Quantities
Parameter/Equipment
Range
CMC
2 (±)
Comments
Fluid Flow – Flowmeters
Volume Gas Flow Rate:
(Reference Fluid
Conditions of 70 °F &
14.696 psia)
0.5 cm
3/min
5 cm3/min
10 cm3/min
(50 to 99) cm3/min
(100 to 149) cm3/min
(150 to 199) cm3/min
(200 to 249) cm3/min
(250 to 299) cm3/min
(300 to 349) cm3/min
(350 to 399) cm3/min
(400 to 449) cm3/min
(450 to 500) cm3/min
(20 to 200) ft3/h
(0 to 10) ft3/min
0.01 cm3/min
0.04 cm3/min
0.13 cm3/min
1.8 cm3/min
2.2 cm3/min
2.3 cm3/min
2.5 cm3/min
2.8 cm3/min
3 cm3/min
3.2 cm3/min
3.5 cm3/min
3.8 cm3/min
6.3 ft3/h
0.12 ft3/min
Alicat volume flow
meter
Medium: nitrogen,
air. | See scope document |
| 7 | ASME B107.14-2004 | - | See scope document |
| 8 | ASTM | - | See scope document |
| 9 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 9 of 12
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Vacuum Manometer,
Vacuum Gauges
(10 to 20) Torr
(20.1 to 50) Torr
(50.1 to 80) Torr
(80.1 to 100) Torr
0.015 Torr
0.08 Torr
0.12 Torr
0.15 Torr
MKS absolute
pressure
transducers
Volume – Pipettes
(10 to 50) µL
(100 to 1000) µL
0.8 µL + 0.42 %
0.82 µL + 0.42 %
Analytical
balance
VI. Thermodynamics
Parameter/Equipment
Range
CMC
2, 5 (±)
Comments
Relative Humidity –
Measuring Equipment
(10 to 55) % RH
(55.1 to 95) % RH
0.48 % RH +
0.0058 % RH / % RH
0.13 % RH +
0.012 % RH / % RH
High precision
humidity
calibrator
Temperature3 – Measuring
Equipment (Digital &
Analog Thermometer &
Temperature Probe)
(-196 to 398) °C
(-100 °C to 398) °C
0.05 °C
0.05 °C
RTD
Temperature
probe & readout
display
Dry block Fluke
9173,9170 &
IsoTech 525 ISIS
Temperature
3 –
Temperature Sources (Dry
Blocks, Liquid Baths,
Calibrators)
(-196 to 400) °C
0.05 °C
RTD temperature
probe & readout
display | -196 to 400 °C |
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 10 of 12
Parameter/Equipment
Range
CMC2 (±)
Comments
Temperature – Infrared
Thermometers
20 °C
0 °C
100 °C
300 °C
500 °C
760 °C
982 °C
1.3 °C
1.5 °C
1.6 °C
2.5 °C
4.3 °C
6.5 °C
8.7 °C
Fluke 9133, Fluke 9132
calibrators
(emissivity = 0.95)
Omega black body Mod:
BB-4A (emissivity =
0.99)
IR Black Bodies3
(-30 to -1) °C
(0 to 150) °C
(250 to 982) °C
1.1 °C
1.2 °C
1.7 °C
Fluke 566HVA-
566 IR thermometer
(emissivity = 0.95)
Fluke 5500A series with
type K T/C
VII. Time & Frequency
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Stopwatch
Up to 24 h
0.06 s /24 h
Timometer
Frequency – Measuring
Equipment
0.1 Hz
10 Hz
100 Hz
500 Hz
1 kHz
10 k Hz
100 kHz
500 kHz
1 MHz
5 MHz
10 MHz
0.058 mHz
1.0 mHz
9.9 mHz
50 mHz
0.15 Hz
1.0 Hz
10 Hz
15 Hz
22 Hz
74 Hz
0.14 kHz
Fluke series 5500A
calibrator
HP 8165A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 11 of 12
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Frequency – Measuring
Equipment (cont)
100 MHz
500 MHz
1000 MHz
1500 MHz
2000 MHz
2500 MHz
3000 MHz
1.3 kHz
6.4 kHz
13 kHz
19 kHz
25 kHz
32 kHz
38 kHz
Rohde & Schwarz
signal generator
Frequency – Measure
0.1 Hz
10 Hz
100 Hz
500 Hz
1 kHz
10 k Hz
100 kHz
500 kHz
1 MHz
5 MHz
10 MHz
100 MHz
3000 MHz
0.000 81 mHz
0.081 mHz
0.81 mHz
0.0043 Hz
0.0061 Hz
0.061 Hz
0.61 Hz
4.3 Hz
0.0061 kHz
0.04 kHz
0.06 kHz
0.61 kHz
18 kHz
Agilent frequency
counter
RPM3 – Contact & Non-
Contact
Measuring Equipment
Measure
(599 to 120 000) RPM
Photo
(10 to 12 000) RPM
Contact
(10 to 599) RPM
(600 to 100 000) RPM
0.17 RPM + 0.0059 %
0.15 RPM + 0.0082 %
1.3 RPM
0.82 RPM + 0.0070 %
TIS-RPM calibrator
Tachometer
____________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3283.01) Revised 07/31/2026 Page 12 of 12
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, the value is defined as the percentage of reading.
5 The type of instrument or material being calibrate d is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges
indicated for the listed measurement parameter.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The stated measured values are determined usin g the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification | ||
| 13 | ISO/IEC 17025:2017; ANSI/NCSLI Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Other Locations
2 other sites in this organization
Labs with overlapping accredited scope in United States
- Aalberts IPSAPageland, SCA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AALFA - KAL Metrology Laboratory, division of AALBORG Instruments & ControlsOrangeburg, NYA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ACR Technical ServicesNewport News, VAA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AH Electronic Test Equipment Repair CenterIslip, NYA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Aldinger Company DBA Quality Control ServicesMilwaukie, ORA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.