Process Sensing Technologies Corp. dba Rotronic Instrument

135 Engineers Rd, Suite 150, 11788, Hauppauge, NY, United States

Visit website
A2LA 5622.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 5622.01 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5622.01) Revised 01/21/2026 Page 2 of 3 Parameter/Equipment Range CMC2, 3 (±) Comments Relative Humidity – Measuring Equipment4 (cont) Selected Point Service Water Activity Meters (4.5 to 5.5) % RH (5.5 to 10.5) % RH (10.5 to 15.5) % RH (15.5 to 26) % RH (26 to 36) % RH (36 to 64) % RH (64 to 66) % RH (66 to 81) % RH (81 to 89) % RH (89 to 94) % RH (94 to 96) % RH (0.045 to 0.055) aw (0.055 to 0.105) aw (0.105 to 0.155) aw (0.155 to 0.26) aw (0.26 to 0.36) aw (0.36 to 0.64) aw (0.64 to 0.66) aw (0.66 to 0.81) aw (0.81 to 0.89) aw (0.89 to 0.94) aw (0.94 to 0.96) aw 0.12 % RH 0.15 % RH 0.17 % RH 0.33 % RH 0.39 % RH 0.45 % RH 0.50 % RH 0.55 % RH 0.58 % RH 0.65 % RH 0.74 % RH 0.0012 aw 0.0015 aw 0.0017 aw 0.0033 aw 0.0039 aw 0.0045 aw 0.0050 aw 0.0055 aw 0.0058 aw 0.0065 aw 0.0074 aw HygroGen humidity generator, chilled mirror, thermistor probe with digital thermometer Humidity generator, chilled mirror, thermistor probe with digital thermometer Temperature – Measuring Equipment Measuring Equipment4 (9 to 21) °C (21 to 25) °C (25 to 46) °C (-95 to 140) °C 0.086 °C 0.068 °C 0.094 °C 0.067 °C Thermistor probe with digital thermometer Drywell calibrator, PRT probe with digital thermometer ___________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5622.01) Revised 01/21/2026 Page 3 of 3 3 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 4 Uncertainty components that can be reasonably attributed to the Unit Under Test have not been utilized in the calculation of the CMC value for this measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
4ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

135 Engineers Rd, Suite 150, Hauppauge, NY, 11788, US

40.82374, -73.20623

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.