Tru Cal International
Bensenville, IL, United States
Visit website- Scope lines
- 21
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 21 scope lines.
A2LA certificate 1278.01 · 21 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 2 of 20
Parameter/Equipment
Range
CMC2 (±)
Comments
Steel Rules
Up to 80 in
0.014 in + 0.000 053 in/in
Standard rule,
reticle
Tape Measures
Up to 40 ft
0.013 in + 0.000 098 in/in
Standard tape,
reticle, push-pull
block
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC
2, 5, 6 (±)
Comments
DC Voltage – Measure
3
Up to 200 mV
200 mV to 2 V
(1 to 20) V
(20 to 200) V
(200 to 1000) V
0.0001 mV + 0.000 005 V/V
0.000 000 41 V + 0.000 003 5 V/V
0.000 004 1 V + 0.000 003 5 V/V
0.000 042 V + 0.000 005 5 V/V
0.000 52 V + 0.000 005 5 V/V
Fluke 8508A
DC High Voltage –
Measure
3
(1 to 30) kV
(31 to 120) kV
0.018 %
0.14 %
Ross VD30
Ross VD120
DC Voltage – Generate
3
(0 to 220) mV
220 mV to 2.2V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
8.9 µV/V + 0.4 µV
5.2 µV/V + 0.7 µV
3.6 µV/V + 2.5 µV
3.6 µV/V + 4 µV
5.6 µV/V + 40 µV
6.6 µV/V + 400 µV
Fluke 5720A
DC Current – Measure3
Up to 100 nA
100 nA to 1 μA
(1 to 10) μA
(10 to 200) μA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
43 µA/A + 0.04 nA
28 µA/A + 0.04 nA
24 µA/A + 0.1 nA
0.000 41 µA + 0.000 012 A/A
0.000 004 mA + 0.000 012 A/A
0.000 041 mA + 0.000 14 A/A
0.0008 mA + 0.000 048 A/A
0.000 016 A + 0.000 19 A/A
HP 3458A opt
002
Fluke 8508A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 3 of 20
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
DC Current –
Measure
3 (cont)
(2 to 20) A
(20 to 100) A
0.015 %
0.077 %
HP 3458A with
Fluke Y5020
Valhalla 2575A
DC Current –
Generate
3
Non-Toroidal
(0 to 220) μA
220 μA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 10.9999) A
(11 to 20) A
(20 to 100) A
(20 to 1000) A
41 µV/V + 6 nA
36 µV/V + 7 nA
36 µV/V + 40 nA
46 µV/V + 0.7 µA
82 µV/V + 12 nA
0.039 % + 0.5 mA
0.042 % + 0.03 % of range
0.068 % + 0.03 % of range
0.58 % + 0.5 A
Fluke 5720A
*Add (200 x I2)
µA/A for I >
100 mA
**Add (10 x I2)
µA/A for I > 1 A
Fluke 5500A
Fluke 5522A
Valhalla 2555A
Fluke 5522A w/
Fluke 5500 coil
Resistance – Measure3
Up to 2 Ω
(2 to 20) Ω
20 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
200 MΩ to 2 GΩ
(2 to 20) GΩ
0.000 004 2 Ω + 0.000 017 Ω/Ω
0.000 014 Ω + 0.000 097 Ω/Ω
0.000 000 53 Ω + 0.000 008 2 Ω/Ω
0.000 005 8 kΩ + 0.000 008 1 Ω/Ω
0.000 056 kΩ + 0.000 082 Ω/Ω
0.000 001 1 MΩ + 0.000 009 2 Ω/Ω
0.0001 MΩ + 0.000 020 Ω/Ω
0.0095 MΩ + 0.0013 Ω/Ω
0.0001 GΩ + 0.000 18 Ω
/ Ω
0.01 GΩ + 0.0015 Ω/ Ω
Fluke 8508A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 4 of 20
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
Resistance – Generate,
Fixed Values
3
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
(1, 1.9) kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
0.011 %
99 µΩ/Ω
24 µΩ/Ω
24 µΩ/Ω
11 µΩ/Ω
11 µΩ/Ω
89 µΩ/Ω
89 µΩ/Ω
90 µΩ/Ω
11 µΩ/Ω
12 µΩ/Ω
21 µΩ/Ω
22 µΩ/Ω
42 µΩ/Ω
49 µΩ/Ω
0.010 %
Fluke 5720A
Resistance – Generate
(0 to 10.999) Ω
(11 to 32.999) Ω
(33 to 109.999) Ω
(110 to 329.999) Ω
330 Ω to 1.0999 kΩ
(1.1 to 3.299) kΩ
(3.3 to 10.999) kΩ
(11 to 32.999) kΩ
(33 to 109.99) kΩ
(110 to 329.999) kΩ
330 kΩ to 1.0999 MΩ
(1.1 to 3.299) MΩ
(3.3 to 10.999) MΩ
(11 to 32.999) MΩ
(33 to 109.999) MΩ
(110 to 329.999) MΩ
(330 to 1100) MΩ
46 µΩ/Ω + 0.001 Ω
27 µΩ/Ω + 0.0015 Ω
24 µΩ/Ω + 0.0014 Ω
24 µΩ/Ω + 0.002 Ω
23 µΩ/Ω + 0.002 Ω
23 µΩ/Ω + 0.02 Ω
24 µΩ/Ω + 0.02 Ω
24 µΩ/Ω + 0.2 Ω
24 µΩ/Ω + 0.2 Ω
26 µΩ/Ω + 2 Ω
26 µΩ/Ω + 2 Ω
54 µΩ/Ω + 30 Ω
0.011 % + 50 Ω
0.022 % + 2.5 kΩ
0.039 % + 3 kΩ
0.24 % + 0.1 MΩ
1.2 % + 0.5 MΩ
Fluke 5522A
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC High Voltage –
Measure
3
Up to 21 kV
(20 to 85) kV
60 Hz
60 Hz
0.71 %
0.99 %
Ross VD30
Ross VD120 | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 5 of 20
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Measure
3
200 mV
2 V
20 V
200 V
1000 V
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 10) Hz
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
0.014 mV + 0.000 17 V/ V
0.0035 mV + 0.0003 V/V
0.004 mV + 0.000 12 V /V
0.002 mV + 0.000 11 V / V
0.002 mV + 0.000 11 V / V
0.008 mV + 0.000 34 V / V
0.02 mV + 0.000 77 V / V
0.000 12 V + 0.000 15 V/V
0.000 021 V + 0.000 12 V/V
0.000 02 V + 0.000 093 V/V
0.000 021 V + 0.000 077 V/V
0.000 021 V + 0.000 11 V/V
0.000 04 V + 0.000 22 V/V
0.0002 V + 0.000 57 V/V
0.002 V + 0.003 V/V
0.02 V + 0.01 V/V
0.0012 V + 0.0015 V/V
0.000 18 V + 0.0012 V/V
0.000 18 V + 0.000 91 V/V
0.0002 V + 0.000 075 V/V
0.0002 V + 0.000 11 V/V
0.0004 V + 0.000 22 V/V
0.002 V + 0.000 57 V/V
0.02 V + 0.003 V/V
0.2 V + 0.01 V/V
0.012 V + 0.000 15 V/V
0.002 V + 0.000 12 V/V
0.002 V + 0.000 091 V/V
0.002 V + 0.000 076 V/V
0.002 V + 0.000 11 V/V
0.0068 V + 0.000 085 V/V
0.02 V + 0.000 57 V/V
0.2 V + 0.003 V/V
0.2 V + 0.003 V/V
0.07 V + 0.000 15 V/V
0.021 V + 0.000 11 V/V
0.02 V + 0.000 12 V/V
0.04 V + 0.000 23 V/V
0.2 V + 0.000 58 V/V
Fluke 8508A | ||
| 6 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 6 of 20
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Generate
3
Up to 2.2 mV
(2.2 to 22) mV
(22 to 220) mV
220 mV to 2.2 V
(2.2 to 22) V
(22 to 220) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
0.027 % + 4 µV
0.014 % + 4 µV
0.013 % + 4 µV
0.023 % + 4 µV
0.052 % + 5 µV
0.11 % + 10 µV
0.14 % + 20 µV
0.28 % + 20 µV
0.027 % + 4 µV
0.014 % + 4 µV
0.013 % + 4 µV
0.023 % + 4 µV
0.052 % + 5 µV
0.11 % + 10 µV
0.14 % + 20 µV
0.28 % + 20 µV
0.026 % + 12 µV
0.012 % + 7 µV
0.012 % + 7 µV
0.022 % + 7 µV
0.048 % + 17 µV
0.092 % + 20 µV
0.14 % + 25 µV
0.28 % + 45 µV
0.025 % + 40 µV
0.010 % + 15 µV
64 µV/V + 8 µV
89 µV/V + 10 µV
0.012 % + 30 µV
0.043 % + 80 µV
0.10 % + 200 µV
0.17 % + 300 µV
0.025 % + 400 µV
92 µV/V + 150 µV
46 µV/V + 50 µV
77 µV/V + 100 µV
0.010 % + 200 µV
0.028 % + 600 µV
0.10 % + 2 mV
0.15 % + 3.2 mV
0.025 % + 4 mV
Fluke 5720A | See scope document |
| 7 | - | AC Voltage; AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 7 of 20
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Generate
3
(cont)
(22 to 220) V
(220 to 330) V
(220 to 1100) V
(330 to 1020) V
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
50 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.011 % + 1.5 mV
79 µV/V + 0.6 mV
0.010 % + 1 mV
0.016 % + 2.5mV
0.092 % + 16 mV
0.45 % + 40 mV
0.82 % + 80 mV
0.016 % + 2 mV
0.017 % + 6 mV
0.021 % + 6 mV
0.026 % + 6 mV
0.16 % + 50 mV
79 µV/V + 3.5 mV
0.021 % + 10 mV
0.025 % + 10 mV
Fluke 5720A
Fluke 5522A
Fluke 5720A
Fluke 5522A
AC Current – Measure
3
Up to 200 μA
200 μA to 2 mA
(2 to 20) mA
(20 to 200) mA
100 mA to 1 A
200 mA to 2 A
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
30 kHz to 100 kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(20 to 50) kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.021 μA + 0.000 50 A/A
0.022 μA + 0.000 50 A/A
0.022 μA + 0.000 71 A/A
0.0002 mA + 0.000 31 A/A
0.0002 mA + 0.000 31 A/A
0.0002 mA + 0.000 71 A/A
0.0002 mA + 0.004 A/A
0.0019 mA + 0.000 32 A/A
0.002 mA + 0.000 31 A/A
0.002 mA + 0.000 71 A/A
0.002 mA + 0.004 A/A
0.02 mA + 0.000 31 A/A
0.02 mA + 0.000 29 A/A
0.02 mA + 0.000 63 A/A
1.2 % + 0.4 mA
0.0002 A + 0.000 62 A/A
0.0002 A + 0.000 74 A/A
Fluke 8508A
HP 3458A opt 002 | - |
| 8 | - | AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 8 of 20
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC Current – Measure
3
(cont)
200 mA to 2 A
(1 to 2) A
(2 to 20) A
(20 to 100) A
(10 to 30) kHz
10 Hz to 5 kHz
(5 to 10) kHz
10 Hz to 5 kHz
(5 to 10) kHz
10 Hz to 1 kHz
0.0002 A + 0.003 A/A
0.03 %
0.12 %
0.09 %
0.58 %
0.12 %
HP 3458A opt 002
Fluke 8508A
with Fluke Y5020A
Fluke 8508A
with Valhalla 2575A
Fluke 8508A, Fluke
Y5020A, Valhalla
2575A
Fluke 8508A
with Valhalla 2575A
AC Current – Generate3
(0 to 220) µA
220 μA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.026 % + 16 nA
0.017 % + 10 nA
0.013 % + 8 nA
0.029 % + 12 nA
0.11 % + 65 nA
0.026 % + 40 nA
0.016 % + 35 nA
0.012 % + 35 nA
0.020 % + 110 nA
0.11 % + 650 nA
0.026 % + 0.4 µA
0.017 % + 0.35 µA
0.014 % + 0.35 µA
0.021 % + 0.55 µA
0.11 % + 6 µA
0.026 % + 4 µA
0.017 % + 3.5 µA
0.012 % + 2.5 µA
0.021 % + 3.5 µA
0.11 % + 10 µA
0.028 % + 35 µA
0.047 % + 80 µA
0.071 % + 0.16 mA
Fluke 5720A | - |
| 9 | - | AC Current; CapacitanceShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 9 of 20
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC Current – Generate
3
(cont)
(2.2 to 11) A
(11 to 20) A
(11 to 100) A
Clamp-On Only Toroidal
(20 to 1000) A
Non-Toroidal
(20 to 1000) A
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 10) kHz
20 Hz to 1 kHz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.055 % + 2 mA
0.084 % + 2 mA
2.4 % + 5 mA
0.097 % + 5 mA
0.12 % + 5 mA
0.58 %
0.12 %
0.97 % + 0.09 A
1.4 % + 0.1 A
1.3 % + 0.25 A
1.5 % + 0.9 A
Fluke 5522A
Vallhalla 2555A
with Vallhalla 2575A
Fluke 5522A with
Fluke 5500 coil
Capacitance – Generate
3
(220.0 to 399.9) pF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.2999) nF
(11 to 32.999) nF
(33 to 109.99) nF
(110 to 329.99) nF
(0.33 to 1.0999) μF
(1.1 to 3.2999) μF
(3.3 to 10.999) μF
(11 to 32.999) μF
(33 to 109.99) μF
(110 to 329.99) μF
(0.33 to 1.099) mF
(1.1 to 3.29) mF
(3.3 to 10.99) mF
(11 to 32.99) mF
(33 to 110) mF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(0 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
0.64 % + 0.01 nF
0.42 % + 0.01 nF
0.42 % + 0.01 nF
0.42 % + 0.01 nF
0.23 % + 0.1 nF
0.22 % + 0.1 nF
0.27 % + 0.3 nF
0.21 % + 1 nF
0.25 % + 3 nF
0.22 % + 10 nF
0.34 % + 30 nF
0.38 % + 100 nF
0.38 % + 300 nF
0.37 % + 1 µF
0.37 % + 3 µF
0.37 % + 10 µF
0.56 % + 30 µF
0.88 % + 100 µF
Fluke 5522A | See scope document |
| 10 | - | CapacitanceShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 10 of 20
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
Capacitance – Generate
3
(cont)
Fixed Points –
1 pF
10 pF
100 pF
1000 pF
0.01 µF
0.1 µF
1 µF
1 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
(0.12, 1, 10, 100) kHz
(0.12, 1, 10, 100) kHz
(0.12, 1, 10, 100) kHz
0.038 %
0.039 %
0.058 %
0.12 %
0.2 %
0.31 %
1.2 %
2.2 %
0.037 %
0.037 %
0.037 %
0.037 %
0.038 %
0.041 %
0.079 %
0.15 %
0.038 %
0.046 %
0.046 %
0.05 %
0.059 %
0.078 %
0.18 %
0.24 %
0.037 %
0.068 %
0.079 %
0.15 %
0.19 %
0.25 %
0.61 %
0.86 %
0.13 %
0.13 %
0.13 %
HP 16381A
HP 16382A, 16383A
HP 16384A
HP 16385A
HP 16386A | See scope document |
| 11 | - | Inductance; AC 4 Terminal ResistanceShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 11 of 20
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
Inductance – Generate
3
Fixed Points
100 µH (100 µH step)
1 mH (1 mH step)
10 mH (10 mH step)
100 mH (100 mH step)
2.3 %
2.4 %
2.4 %
1.2 %
Gen Rad 1490F
AC 4 Terminal Resistance
– Generate
1 mΩ
10 mΩ
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
DC
DC
DC
DC
DC
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
DC
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
DC
100 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
DC
100 kHz
1 MHz
0.23 %
0.23 %
0.23 %
0.23 %
0.12 %
0.12 %
0.13 %
0.14 %
0.14 %
0.16 %
0.42 %
0.62 %
0.12 %
0.12 %
0.13 %
0.13 %
0.13 %
0.13 %
0.24 %
0.33 %
0.12 %
0.12 %
0.12 %
0.12 %
0.12 %
0.13 %
0.13 %
0.24 %
0.33 %
0.12 %
0.12 %
0.12 %
Agilent 42030A | - |
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 12 of 20
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC 4 Terminal
Resistance – Generate
(cont)
100 kΩ
DC
100 kHz
1 MHz
0.12 %
0.13 %
0.13 %
Agilent 42030A
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Oscilloscope – Generate
3
DC Signal
50 Ω Load
1 MΩ Load
Squarewave Signal
50 Ω Load
1 MΩ Load
Edge Characteristics
(50 Ω Load)
Risetime
(50 Ω Load)
Level Sine Wave,
Into 50 Ω Load
5 mV pk-pk to
5.5 V pk-pk
Time Marker, 50 Ω
1 mV to 6.6 V
(0 to 130) V
1.0 mV
pk-pk to 6.6 Vpk-pk
1.0 mVpk-pk to 130 Vpk-pk
5 mV to 2.5 V
≤ 300 ps
50 kHz reference
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
5 s to 50 ms
20 ms to 2 ns
0.19 % + 40 μV
0.039 % + 40 μV
0.19 % + 40 μV
0.078 % + 40 μV***
1.6 % + 0.2 mV
(+ 0 / -78) ps
1.9 % + 0.3 mV
2.9 % + 0.3 mV
3.3 % + 0.3 mV
4.8 % + 0.3 mV
(25 + 1000t) µs/s
25 µs/s
Fluke 5500A SC600
*** > 1 kHz,
uncertainty is 0.25 %
+ 40 μV
Fluke 5500A SC600
t = time in seconds
DC High Voltage –
Generate
3
Up to 10 kV
0.33 % of range
Fluke 410B | ||
| 13 | - | Thermocouple Indicating Devices; RTD Devices; RF Attenuation; RF Power MeasureShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 13 of 20
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
Thermocouple Indicating
Devices
3 –
Type E
Type J
Type K
Type T
(-250 to -100) °C
(-100 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.39 °C
0.14 °C
0.17 °C
0.21 °C
0.14 °C
0.18 °C
0.20 °C
0.11 °C
0.15 °C
0.24 °C
0.20 °C
0.11 °C
0.10 °C
0.15 °C
Fluke 5500A
Electrical Calibration of
RTD Devices
3
PT 385, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.04 °C
0.04 °C
0.05 °C
0.08 °C
0.08 °C
0.10 °C
0.19 °C
Fluke 5522A
IV. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC
2, 6 (±)
Comments
RF Attenuation (Tuned) –
RF Power Measure
3
(10 to -100) dBm
2.5 MHz to 1.3 GHz
0.17 dB
HP 8902A with opt 050
& HP 11722A power
sensor | See scope document |
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 14 of 20
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
RF Attenuation (Tuned) –
RF Power Measure
3 (cont)
(10 to -100) dBm
(-100 to -120) dBm
(1.3 to 26.5) GHz
(1.3 to 26.5) GHz
0.28 dB
0.32 dB
HP 8902A w/ 11793A
down converter & HP
11792A power sensor
RF Absolute
Power – Measure
(-70 to -20) dBm
(-20 to 10) dBm
10 MHz to 18 GHz
100 kHz to 26.5 GHz
0.15 dB
0.15 dB
HP 438A
w/8481A/8482A/8484A/
8485A
RF Power – Generate3
(0 to -18) dBm
(-18 to -58) dBm
(-58 to -98) dBm
(+10 to -100) dBm
200 Hz to 81 MHz
200 Hz to 81 MHz
200 Hz to 81 MHz
2.5 MHz to 26.5 GHz
0.05 dB
0.11 dB
0.23 dB
0.6 dB
HP 3335A
HP 8340B synthesizer
w/8902; 11722A,
11792A sensors,
11793A converter
Amplitude Modulation –
Measure
3
Rate: 50 Hz to 10 kHz
Depths: (5 to 99) %
Rate: 20 Hz to 10 kHz
Depths: Up to 99 %
Rate: 50 Hz to 50 kHz
Depths: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depths: (5 to 99) %
Rate: 50 Hz to 50 kHz
Depths: (5 to 99) %
150 kHz to 10 MHz
150 kHz to 10 MHz
10 MHz to 1.3 GHz
10 MHz to 1.3 GHz
(1.3 to 18) GHz
2.8 % + 1 digit
3.8 % + 1 digit
1.7 % + 1 digit
3.7 % + 1 digit
3.2 % + 1 digit
HP 8902A
HP 8902A
HP 8902A, 11793A | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 15 of 20
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
Amplitude Modulation –
Measure
3 (cont)
Rate: 20 Hz to 100 kHz
Depths: Up to 99 %
10 MHz to 26.5 GHz
4.7 % + 1 digit
HP 8902A, 11793A
Frequency Modulation –
Measure3
Rate: 20 Hz to 10 kHz
Dev: ≤ 40 kHz pk
Rate: 50 Hz to 100 kHz
Dev: ≤ 400 kHz pk
Rate: 20 Hz to 200 kHz
Dev: ≤ 400 kHz pk
Rate: 50 Hz to 100 kHz
Dev: ≤ 400 kHz pk
150 kHz to 10 MHz
10 MHz to 1.3 GHz
10 MHz to 1.3 GHz
10 MHz to 26.5 GHz
2.9 % + 1 digit
1.9 % + 1 digit
6 % + 1 digit
3.5 % + 1 digit
HP 8902A
HP 8902A, 11793A
Phase Modulation –
Measure
3
Rate: 200 Hz to 10 kHz
Rate: 200 Hz to 20 kHz
Rate: 200 Hz to 20 kHz
150 kHz ≤ f
c < 10 MHz
10 MHz ≤ f
c ≤ 1.3 GHz
10 MHz ≤ fc ≤ 26.5 GHz
5.3 % + 1 digit
4.3 % + 1 digit
5.2 % + 1 digit
HP 8902A
HP 8902A, 11793A
f
c represents the
frequency carrier
Harmonic Distortion/Total
Harmonic Distortion –
Measure
30 Hz to 26.5 GHz
(2 to 6) GHz
(6 to 13) GHz
(13 to 21) GHz
(21 to 26) GHz
20 Hz to 20 kHz
(20 to 100) kHz
1.5 dB
1.7 dB
2.6 dB
2.9 dB
3.8 dB
1.2 dB
2.3 dB
HP 8563E
HP 8903B | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 16 of 20
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Power Meters, Fixed
Points
3 –
Instrument Accuracy
(3, 10, 30, 100, 300) µW
(1, 3, 10, 30, 100) mW
0.32 %
0.32 %
Range
calibrator,
Agilent
11683A
V. Mechanical
Parameter/Equipment
Range
CMC
2, 5, 8 (±)
Comments
Torque Wrench
3
Up to 100 lbfꞏin
Up to 240 lbfꞏin
(20 to 650) lbf∙ft
0.55 %
0.60 %
0.50 %
AKO TSD
1200, TSD
821, TSD 011
torque
calibrator
Pressure & Vacuum Gages3
–
Pneumatic
Hydraulic
(-14.5 to 30) psig
(Up to 5) psig
(Up to 100) psia
Up to 18 torr
Up to 100 psig
(100 to 1000) psig
(1000 to 10 000) psig
0.01 psi
0.004 psig
0.07 psia
0.015 torr + 0.000 32 torr/torr
0.03 psi
0.25 psi
2.2 psi
Pressure
calibrator,
Fluke 525B
w/750 sensors
Furness
FC560
Pressure
calibrator,
Fluke 525B
w/750
sensors
RPM – Measure
3
(Non-Contact)
(6 to 599.9) rpm
(600 to 9999) rpm
(10 000 to 99 999) rpm
1.2 rpm
0.6 rpm + 0.000 075 rpm/rpm
1.7 rpm + 0.000 073 rpm/rpm
Shimpo MT-
200 optical
tachometer | ||
| 17 | - | weights; graduated cylinder; flask; beaker; PRT probe; bath; saltShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 17 of 20
Parameter/Equipment
Range
CMC2, 4, 5, 8 (±)
Comments
Scales
3
(1 to 100) g
(100 to 400) g
(400 to 500) g
(0.5 to 1.5) kg
(1.5 to 2.5) kg
(2.5 to 3.5) kg
(3.5 to 8.5) kg
(8.5 to 15) kg
(15 to 60) kg
(5 to 350) lb
0.0006 g
0.0009 g
0.003 g
0.009 g
0.013 g
0.016 g
0.031 g
0.059 g
0.20 g
0.0014 lb + 0.000 019 lb/lb
Class 2 weights
Class F weights
Balances3
(50 to 500) mg
(5 to 100) g
0.015 mg + 0.000 028 mg/mg
0.11 mg + 0.000 002 g/g
Class S weights
Graduated
Cylinder/Flask/Beaker
(5 to 5000) mL
0.12 % + 0.004 mL
Balance
Force Measuring
Equipment – Gages
Up to 300 lbf
0.19 lbs + 0.044 %
Class F weights
VI. Thermodynamics
Parameter/Equipment
Range
CMC2, 5, 8 (±)
Comments
Temperature –
Measure
3
(-170 to 660) °C
0.023 °C
Hart 5626 PRT
probe with Azonix
1011 display
Temperature –
Measuring Equipment
3
(35 to 200) °C
0.024 °C
Hart 5626 PRT with
Azonix 1011
display, Hart 6102
bath
Relative Humidity
–
Measuring Equipment3
11.5 % RH
33 % RH
75 % RH
1.4 % RH
1.4 % RH
1.4 % RH
Salt w/Vaisala
HMT-337 | - |
| 18 | - | Relative Humidity; Timers & Stopwatches; Frequency; Optical TachometersShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 18 of 20
Parameter/Equipment
Range
CMC2, 5, 8 (±)
Comments
Relative Humidity
–
Measuring Equipment3
(cont)
(15 to 80) % RH
1.5 % RH
Tenney BTRC
w/Vaisala HMT-337
Relative Humidity –
Measure
3
(11.5 to 90) % RH
(90 to 95) % RH
1.4 % RH
2.1 % RH
Vaisala HMT-337
VII. Time & Frequency
Parameter/Equipment
Range
CMC2, 4, 5, 8 (±)
Comments
Timers & Stopwatches
3
Seconds per day
0.07 s/day
Timometer TM-
4500 from Helmut
Klein
Frequency – Measuring
Equipment, Fixed Point
10 MHz reference
4.1 parts in 10
-11 Hz/Hz
at 1 day
GPS with
Symmetricom Xli
Frequency –
Measuring Equipment
1 mHz to 100 Hz
100 Hz to 100 kHz
100 kHz to 100 MHz
100 MHz to 26.5 GHz
8.2 parts in 10
-8 Hz/Hz
9.3 parts in 10-8 Hz/Hz
9 parts in 10-9 Hz/Hz
2.1 parts in 10-9 Hz/Hz
GPS with
Symmetricom Xli
w/HP 3325B
HP8904A
HP8648C
HP8340B
Frequency –
Measure
1 mHz to 100 Hz
100 Hz to 100 kHz
100 kHz to 100 MHz
100 MHz to 26.5 GHz
8.2 parts in 10
-8 Hz/Hz
9.3 parts in 10-8 Hz/Hz
7.4 parts in 10-9 Hz/Hz
2.1 parts in 10-9 Hz/Hz
GPS with
Symmetricom Xli
w/HP53131A
HP 5352B
Optical Tachometers
(10 to 100 000) rpm
0.0037 % + 6R
HP 3325B, HP
5334B, LED fixture | 10 to 100000 rpm |
| 19 | - | Balances & ScalesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 19 of 20
SATELLITE FACILITY
TRU CAL INTERNATIONAL, INC.
333 Pfingsten Rd
Northbrook, IL 60062
Shauna Ernst Phone: 630 238 8100
I. Mechanical
Parameter/Equipment
Range
CMC
2 (±)
Comments
Weight Measure by
Balances & Scales
(5 to 500) g
> 500 g to 5 kg
>(5 to 10) kg
>(10 to 60) kg
3.1 mg
38 mg
0.11 g
1.5 g
Mettler XP5003SDR
Ohaus EX10202 &
GP-61K
___________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches;
and R is the resolution of the device.
5 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
6 The stated measured values are determined using indicated instruments (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus fixed floor specification.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | 5 to 500 g |
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1278.01) Revised 03/30/2026 Page 20 of 20
8 The type of instrument or material being calib rated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 21 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Aalberts IPSAPageland, SCA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AALFA - KAL Metrology Laboratory, division of AALBORG Instruments & ControlsOrangeburg, NYA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ACR Technical ServicesNewport News, VAA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AH Electronic Test Equipment Repair CenterIslip, NYA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Aldinger Company DBA Quality Control ServicesMilwaukie, ORA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.